manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Associated Controls
  6. •
  7. Lighting Equipment
  8. •
  9. Associated Controls AsconPool C1070 User manual

Associated Controls AsconPool C1070 User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

C1070 Installation Diagram
Dual output timer
control centre
Model C1070
Pressure Cleaner/Booster Pump
The sun always shines with Ascon Pool
Associated Controls (Australia) Pty Limited,
ABN 210 002 245 64
2-4 Norfolk Rd, Greenacre NSW 2190, Australia
PO Box 5605, Chullora NSW 2190
Tel: 61 2 9642 4922
Email: [email protected] web: www.asconpool.com.au
22384-01.pdf 104097
C1070 Dual Output Timer Control Centre INSTALLATION
The C1070 is designed to give you year round automatic control of your swimming
pool cleaning system. By following these simple installation and operating
instructions you will enjoy trouble free operation for many years.
THIS UNIT IS COVERED BY A LIMITED 12-MONTH WARRANTY. Please
refer to the web site for warranty details.
CAUTION: DO NOT OPEN THE CASE OF THE C1070 UNIT. IT IS NOT USER
SERVICEABLE. IF THE POWER CORDS ARE DAMAGED, IT MUST BE
REPLACED BY THE MANUFACTURER OR AN AUTHORISED AGENT.
OPENING THE CASE WILL VOID YOUR WARRANTY. THIS UNIT MUST BE
INSTALLED IN THE UPRIGHT POSITION.
INSTALLATION
The C1070 unit is weather resistant, however it should be mounted in a sheltered
position where it is not exposed to direct weather, splashing or spray from the pool
or filtration equipment. Electrical building regulations specify that the C1070
unit must not be mounted within 3 meters of the pool.
Fix the unit to a wall or post, within 1.5 meters of a 240-volt outlet and within 2
meters of the cleaning pump. Mounting points are provided on the back. The C1070
unit must be installed in the upright position.
Power connection. Power to the C1070 is supplied via the outlet from the time
clock or chlorinator through a standard 240-volt lead and plug (marked TO
TIMECLOCK / CHLORINATOR). Power for the pressure cleaner booster pump is
supplied through a separate standard 240-volt lead and plug (marked CONSTANT
240Vac).
Plug the cleaning pump into the socket marked BOOSTER PUMP and plug the filter
pump into the socket marked FILTER PUMP (See installation diagram).
Maximum Booster Pump rating: 1 HP
Maximum Filter Pump rating: 1.5 HP
ONLY THE FILTER PUMP IS TO BE CONNECTED TO THE FILTER PUMP
OUTLET. ONLY THE BOOSTER PUMP IS TO BE CONNECTED TO THE
BOOSTER PUMP OUTLET MORE THAN THIS OR EQUIPMENT OTHER THAN
A PUMP MAY DAMAGE THE ELECTRONICS OR THE ITEM CONNECTED TO
THE CONTROLLER OUTLET AND WILL VOID YOUR WARRANTY.
OPERATION
The C1070 Dual output timer control centre is designed to give the user trouble
free, low maintenance control of the cleaning pump. The C1070 unit is designed to
be set up and left. Once set up the C1070 unit will turn on each day, 16 minutes
after power is supplied to the filter pump and run for the user selected time. Time
remaining for the controllers operation is indicated by that hour light flashing.
+ AND - BUTTONS
These buttons allow the user to select between 1 and 5 hours for the cleaning pump
to run.
OVERRIDE ON
This button allows the user to run the C1070 unit for extra time for either 1 or 4
hours. The override will then time out after the 1 or 4 hour period and turn off
automatically. Override on 1-hour selection is displayed by the pump light being lit
up, the override on light flashing and the 1-hour light flashing. The 4-hour override
is displayed by the pump light lit up, the override on light lit up and the 4-hour lights
lit up (the current hour the unit is in will be flashing). To select 1-hour just press the
button till the override on light is flashing. To select 4 hours hold the button until
the override on light is lit and the 4-hour lights are lit. To cancel the override on
function, press the override on button until the override on light is off.
OVERRIDE OFF
The override off button turns the C1070 unit off for just 1 hour and then times out
and continues normal operation again. This is selected by pressing the override off
button until the override off light is lit. To cancel the override off function, press the
override off button until the override off light is off.