Atlas IED AP-S15A User manual

– 1 –
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
AP-S15A
AC Power Conditioner & Distribution Unit

– 2 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Table of Contents
Important Safety Instructions................................................................................................................................................................................. 3
Introduction .......................................................................................................................................................................................................... 5
Key Features and Applications .............................................................................................................................................................................. 6
Front Panel Description .......................................................................................................................................................................................... 7
Rear Panel Description ........................................................................................................................................................................................... 8
Installation ............................................................................................................................................................................................................. 9
AC Power Cord Retainer System .......................................................................................................................................................................... 9
Specifications .......................................................................................................................................................................................................11
Warranty ............................................................................................................................................................................................................... 12

– 3 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this device near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other device that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the
device.
11. Only use attachments / accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used, use caution
when moving the cart / device combination to avoid injury from tip-over.
13. Unplug this device during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as power-supply cord
or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed to rain or moisture, does not
operate normally, or has been dropped.
15. This product is equipped with a three-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type
power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do
not defeat the safety purpose of the grounding-type plug.
16. WARNING: To reduce the risk of fire or electric shock, this device should not be exposed to dripping, splashing, rain, or moisture, and objects filled
with liquids, such as a vase, should not be placed on this device.
17. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle.
18. The mains plug of the power supply cord shall remain readily operable.
19. Protective earthing terminal. The apparatus should be connected to a mains socket with a protective earthing connection.
The lightning flash with arrowhead symbol within an equilateral triangle,
is intended to alert the user to the presence of uninsulated “dangerous
voltage “ within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to
alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product.
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING:TO REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSETHIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE

– 4 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
WARNING - When The Device Is In Use
• WARNING: For the terminals marked with symbol of may be of sufficient magnitude to constitute a risk of electric shock. The external wiring
connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.
• WARNING: The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on
apparatus.
• WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
• To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to
AtlasIED.
• Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and
contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock:
• Smoke or strange smell coming from the unit.
• If the product falls or the case is damaged.
• If water or any metallic objects falls into the product.
• If the power supply cord is damaged in any way.
• If the unit is malfunctioning.
• Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in electric shock or
fire.
• Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric shock may result.
• Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.
• Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result.
• Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.
• Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects on the power
cord, including the product itself, doing so may result in fire or electrical shock.
• Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic disaster may
result.
• Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.
CAUTION - When Installing The Product
• Plugging in or unplugging the power cord with wet hands may result in electric shock.
• Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.
• When unplugging the cord from the wall, grasp the plug, NOT the cord.
• Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or steam are
present. Fire and electric shock may result.
• Keep all sides of the unit at least 31/2" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.
CAUTION - When The Product Is In Use
• Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addition, the product
itself may fall and cause injury and property damage.
• Contact AtlasIED for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat buildup and fire.
• Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or inside the wall
outlet.
• When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

– 5 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Introduction
Thank you for purchasing the AtlasIED AP-S15A AC Power Conditioner & Distribution Unit. The AP-S15A has been designed to meet most installation
requirements for AC power distribution and equipment power protection.
The AP-S15A features noise filtering for unwanted Radio Frequency Interference (RFI) that is commonly introduced into AC lines by nearby radio
transmitters or wireless products. EMI filters are incorporated to reduce noise from Electromagnetic Interference (EMI) from such items as electric
motors and switching power supplies. The benefit of these filters can be seen on video products or audibly by reducing static pops and external signal
interference.
The AP-S15A is unique in that the integrator can select the power cord length that is required for the installation. A removable 12' IEC power cord with
a retainer bracket is supplied with the unit. A shorter or longer cord can be purchased separately if needed.
Unstable AC Mains voltage is one of the main reasons for equipment failure. The amount of energy that can be injected into the power system can be
immense with voltages reaching 6kV or amperage peaks of 3000A. These spikes are very fast and usually only last for a very short period of time. The
AP-S15A’s circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds,
thus ensuring virtually trouble free protection. The front panel also features AC fault and ground status indicators providing quick, visual reassurance the
equipment is safe.
The AP-S15A offers power management control, noise filtering, and spike / surge protection, making it the most compact, effective power
management protection system on the market today.

– 6 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Key Features
• 9 Total Outlets
• 7 Rear Panel Switched Outlets
• 1 Rear Panel Unswitched Outlet
• 1 Front Panel Unswitched Convenience Outlet
• RFI Noise Filtering to Reduce Radio Frequency Interference
• EMI Filtering to Reduce Electromagnetic Interference
• Circuit Breaker Protection @ 15A
• Spike Suppression up to 6000V
• AC Fault Indicator
• Ground Status Indicator
• Removable IEC Power Cord with a Retainer Bracket
Applications
The AP-S15A was designed to be flexible with features that allow it to be used in a variety of applications. The AP-S15A can be used solely for
protection against voltage surges or for AC distribution. If fuzzy video or frequent static pops occur, the AC power conditioning may eliminate or reduce
those inconveniences. The following are just a few examples of applications where the AP-S15A can be used:
• Restaurants
• Houses of Worship
• Schools
• Home Theaters
• Office Buildings
• Sports Bars

– 7 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Front Panel
1. Unswitched AC Outlet
The 120VAC outlet is always live when the AP-S15A power cord is plugged into an AC mains power source. Note: The AC mains power switch does
not affect the Unswitched AC Outlet but it is protected with surge protection circuitry.
2. Power Switch & Cover
To turn the AP-S15A On or Off, press the switch to the On (up) or Off (down) position. When the Power Switch is in the On (up) position and the power
cord is plugged into 115V - 120V and voltage is present, the Blue Power LED will illuminate. When the Power Switch is in the Off (down) position the
Blue Power LED will not be illuminated. Note: The Protect and Ground LEDs will be illuminated when the Power Switch is in the Off (down) position
when operating correctly. The AP-S15A incorporates a power switch cover to prevent accidental pressing of the power switch.
3. Switched Outlets Active Indicator
This LED will illuminate Blue when the power switch is in the On position.
4. Surge Protect Indicator
The Surge Protect LED is illuminated Red under normal operating conditions showing that the surge protection circuit is functioning correctly and the
connected equipment is protected from voltage transients. Note: The Surge protection LED will be illuminated regardless of the Power Switch being
in the On or Off position. Although the clamping suppression circuit virtually assures protection from most transient voltage spikes and surges, nature
has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage. In the
rare instance that this occurs and the circuit has been damaged, the Red “Surge Protect” LED indicator will turn Off. If the Surge Protection LED in
off, all AC outlets will remain functional but the device will have no surge protection. It is recommended to stop using the unit or future damage may
occur to the devices connected to this unit. Be advised that activation of this fault condition and the associated repair is not covered under warranty.
Note: If the Surge Protect LED is not illuminated while the unit is powered on, it is important to have all equipment that was connected to that AC
Mains Line inspected for proper operation.
5. Ground Status Indicator
This LED will illuminate Green regardless of the Power Switch being in the On or Off position and when the AP-S15A has Earth ground connection
on the Earth ground pin of the AC Mains power cord. If the Ground Status LED in off, all AC outlets will remain functional but the device will have no
Earth ground. It is recommended to stop using the unit or future damage may occur to the devices connected to the unit. Note: If there is no Earth
ground connection the LED will not illuminate and the AC wall outlet must be repaired by a qualified electrician before continuing.
12 3
4
5

– 8 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Rear Panel
1. AC Mains Input
Connect the IEC 14 Gauge 12'(4m) power cord to a 15A 120VAC outlet to provide power to the AP-S15A.
2. AC Mains Input IEC Power Cord Retainer
The AP-S15A incorporates an IEC power cord retainer bracket to prevent the cord from coming loose. See IEC power cord retainer bracket installation.
3. AC Mains Power Breaker
The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A. Note: The breaker is designed to exceed its rating for a short
period of time. If the breaker is tripped, the load must first be removed from the AP-S15A before pushing to reset.
4. Unswitched AC Outlet
The 120VAC outlet is always live when the AP-S15A power cord is plugged into an AC mains power source. Note: The AC mains power switch does
not affect the Unswitched AC Outlet but it is protected with surge protection circuitry.
5. Switched AC Outlets
The seven 120VAC outlets are always live when the AP-S15A front panel power switch is in the On position.
1 2345

– 9 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Installation
Before installing, read the entire manual to ensure proper understanding of operation and that all features are being utilized. The AP-S15A can be
placed on a shelf or rack mounted in a standard 19" width rack. When rack mounted, placement within the rack is flexible, however the AP-S15A should
be within 6' of a dedicated 15A AC outlet. When rack mounting, use rack rail type screws of 10/32" x 1". Always make sure the 15A outlet is properly
inspected by a certified electrician prior to connecting the AP-S15A. Make sure to inspect the equipment that will be connected to the AP-S15A to
ensure it does not exceed 15A total amperage draw.
AC Power Cord Retainer System
Connect the IEC 14 Gauge 12' (4m) power cord to a 15A 120VAC outlet to provide power to the AP-S15A by aligning the pins of the cord to the pins on
the chassis and inserting the cord. Press firmly to assure a good connection.
The AP-S15A incorporates an IEC Power Cord retainer bracket to prevent the cord from coming loose. To install the IEC power cord retainer bracket,
remove the two screws from the chassis of the AP-S15A, place the retainer bracket over the cord and insert the two screws through the bracket into
the chassis as illustrated below.

– 10 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
System
Type Power Conditioner & Suppressor
Load Rating 15A
Safety Listings UL 60950-1 Standard
Front Panel
Outlets 1 Unswitched, Note: All Outlets are Surge and RF Protected
Activation Switch Rocker with Security Cover
Indicators AC Power ON (Blue), Surge Protect (Red), Ground (Green)
Rear Panel
AC Outlets 8 Outlets Total, 7 Switched & 1 Unswitched
AC Mains IEC Power Socket 15A 1800W
Circuit Breaker 15A Resettable
Technical
Max AC Mains Current 15A AC Mains Breaker
Operating Voltage 102VAC - 132VAC
Power Consumption 6 Watts
Min. Spike Clamping Voltage 460 VRMS @ 3,000A
Max. Spike Clamping Voltage 6kV
Max. Spike Clamping Resp. Time 1 nanosecond
Spike Clamping Voltage @ 100A 1250Vp for 20µs
Maximum Surge Current 6,500A
Energy Rating @ 2ms 200 Joules
Noise Attenuation RFI 10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz
Temperature Range 5° to 35°C
Humidity Range 5% to 95% Relative Humidity
Mechanical
Color Black
Rack Mount Requirements 1 RU, 19"
Weight (Net) 5 lbs (2.27kg)
Dimensions 19" W x 1.75" H x 5" D (483mm x 45mm x 127mm)
In The Box
Manual
IEC Power Cord 14 Gauge 12ft (4M)
IEC Power Cord Retainer Bracket
Warranty Coverage
Warranty Period 3 Years

– 11 –
AP-S15A
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Dimensional Drawings
120V 60Hz 12A 1440W
Unswitched Outlet
Power
Surge
Protect
LEDs Off When
Fault Is Detected
AC
Ground
Push To Reset
15A Circuit Breaker
Switched Outlets - 120V 60Hz 12A 1440W 15A 1800W Max
AC 120V 60Hz
120V 60Hz 12A 1440W
Unswitched Outlet
CAUTION!
RISK OF ELECTRICAL SHOCK. DO NOT OPEN.
REFER SERVICINGTO QUALIFIED SERVICE PERSONNEL.
TO REDUCETHE RISK OF FIRE OR ELECTRICAL SHOCK
DO NOT EXPOSETHIS EQUIPMENTTO RAIN AND MOISTURE.
AVIS: RISQUEDE CHOC
ELECTRIQUE - NE PASOUVRIR
Power Distribution Unit
Model: AP-S15A
Voltage Protection Rating: 400V(L-N) 500V(L-G) 400V(N-G)
Electrical Rating : 12A 125V AC 60Hz 1500W
Made in China ID:S
Caution:
To reduce the risk of electric shock, use only in dry locations indoors!
Do not plug into another relocatable power tap. The input plug of this
power distribution unit is intended to serve as the disconnect device,
it shall be easily accessible and withdrawn. If you want to have an output
rating of 15A, you shall use a power supply cord with a 5-20P plug.
If you use a power supply cord with a 5-15P plug, the output would
only be 12A.
I.T.E.
E467418
33FG
1601 JackMcKay Blvd.
Ennis,TX 75119
800.876.3333 AtlasIED.com
AP-S15A
15A AC Power Conditioner
& Distribution Unit
1.75"
(45mm)
3.75"
(96mm)
5"
(127mm)
19"
(483mm)
17"
(432mm)

– 12 –
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
©2022 Atlas Sound L.P. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a registered trademark of Innovative Electronic Designs LLC. All Rights Reserved.
All other trademarks are the property of their respective owners. All specs are subject to change without notice. ATS004891 RevD 11/22
Limited Warranty
All products manufactured by AtlasIED are warranted to the original dealer / installer, industrial or commercial purchaser to be free from defects in
material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for
a period of three years on all AtlasIED products, including SOUNDOLIER brand, and ATLAS SOUND brand products except as follows: one year on
electronics and control systems; one year on replacement parts; and one year on Musician Series stands and related accessories. Additionally, fuses
and lamps carry no warranty. AtlasIED will solely at its discretion, replace at no charge or repair free of charge defective parts or products when the
product has been applied and used in accordance with our published operation and installation instructions. We will not be responsible for defects
caused by improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water
immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power, altered, serviced or installed
in other than a workman like manner. The original sales invoice should be retained as evidence of purchase under the terms of this warranty. All
warranty returns must comply with our returns policy set forth below. When products returned to AtlasIED do not qualify for repair or replacement
under our warranty, repairs may be performed at prevailing costs for material and labor unless there is included with the returned product(s) a written
request for an estimate of repair costs before any nonwarranty work is performed. In the event of replacement or upon completion of repairs, return
shipment will be made with the transportation charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY, ATLASIED
SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE
INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT
NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
AtlasIED does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability.
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
Service
Should your AP-S15A require service, please contact the AtlasIED warranty department through the online warranty claim process.
Online Warranty Claim Processes
1. Warranty submissions are accepted at: https://www.atlasied.com/warranty_statement where the type of return Warranty or Stock return can be
selected.
2. Once selected, you will be prompted to enter your login credentials. If you do not have a login, register on the site. If already logged-in, navigate to
this page by selecting “Support” and then “Warranty & Returns” from the top menu.
3. In order to file a Warranty Claim, you will need:
A. A copy of the invoice / receipt of the purchased item
B. Date of Purchase
C. The product name or SKU
D. The serial number for the item (if no serial number exists, enter N/A)
E. A brief description of the fault for the claim
4. Once all required fields are completed, select the “Submit Button”. You will receive 2 emails:
1. One with a confirmation of the submission
2. One with a case# for your reference should you need to contact us.
Please allow 2-3 business days for a response with a Return Authorization (RA) number and further instructions.
AtlasIED Tech Support can be reached at 1-800-876-3333 or atlasied.com/support.
Visit our website at www.AtlasIED.com to see other AtlasIED products.
Table of contents
Other Atlas IED AC Power Distribution manuals