Atop IO5202 Series Manual

Industrial IoT Remote I/O
IO5202 Series
Version 1.1
Updated in October, 2021
P/N : 89900584G
www.atoponline.com
+ 886-3-5508137
+ 886-3-5508131
Inside the package you will find the following items:
■ Industrial IoT remote x 1
■ 3-Pin lockable terminal block for power x 1
■ 10-Pin I/O terminal blocks x 2
■ 5-Pin lockable terminal block for serial port x 1 (-TB models only)
■ Installation guide with warranty card x 1
Never install or work on electrity or cabling during periods of lightning activity.
Never connect or disconnect power when hazardous gases are present.
Warning: Hot surface, do not touch. RESTRICTED ACCESS AREA: The equipment
should only be installed in a Restricted Access Area.
IndoorIndoor
This equipment should be installed indoors and not connected directly with
equipment installed outdoors.
1. Grounding Screw
2. Terminal for Power
3. Frame Ground
4. Reset Button
1
3
4
2V+
F.G.
IO5202-DB Series Front ViewIO5202-TB Series Front View
PWR RUN
TX RX
COM
LAN2LAN1
2
3
4
5
6
8
7
1
PWR RUN
TX RX
COM
LAN2LAN1COM
7
2
3
4
5
6
9
1
1. System Power LED
2. System Run LED
3. COM LED-TX
4. COM LED- RX
5. 10/100 Ethernet Port 2
6. 10/100 Ethernet Port 1
7. I/O Port
8. TB-COM Port
9. DB-COM Port
Once the plate is firmly in place, proceed to mount the
whole device as shown in (Fig.2). Refer to (Fig. 3) if
you want to remove the device from the DIN-Rail.
2.
Connet the device to the LAN (switch or PC, depending on the case), taking
care when using the RJ-45 connector. Afterwards, you can proceed to the
device’s settings.
3.
4. Although internal grounding has been done inside, hazardous
ESD can come into contact and damage your equipment. In
order to ensure overall maximum performance and to protect
your device, it is still strongly advised to ground the device
properly.
On the power terminal block, there is a terminal for Frame
Ground. You can connect it either to grounding or to the ground-
ing screw next to the terminal block (the one chosen should be
connected at all times) (Fig. 4).
1
2
(Fig. 3)
1
2
(Fig. 2)
■ The openings on the device's sides are for heat dissipation.
Never obstruct, cover, or try to insert anything through them.
Color State
LED Description
Green On
Off
PWR is connected
PWR is disconnected
PWR
Green On
Off
System is booted up and running
System is still booting up or powered off
RUN
Green Blinking
Off
COM 1 is transmitting
COM 1 is not transmitting
TX COM
Green Blinking
Off
COM 1 is receiving
COM 1 is not receiving
RX COM
Power input: 12 to 48 VDC; 0.8A max
If you have purchased the wall mount kit, proceed to place
the screws on the back of the device as shown in (Fig. 1).
1.
Wall mount screw specifications: M3 0.5p
Screw depth: 4 mm (Max)
Screws x 4 pcs
(Fig. 1)
V+
F.G.
(Fig. 4)
10/100Base-T(X) Ethernet Pinouts
9-Pin Male D-sub Connector for RS-232/422/485
Pin
1DCD - -
2RxD TxD+ Data+
3 TxD RxD+ -
4DTR - -
5 SG SG SG
6DSR - -
7RTS RxD- -
8CTS TxD- Data-
9 RI - -
RS-232 2-wire RS-485
RS-422 and
4-wire RS-485
9
5 4 32 1
8 7 6
5-Pin Terminal Block for RS-232/422/485
Jumper setting for DI/DO ( 8-4-0-0 model only)
2 x 10-Pin Terminal block for I/O
Pin
1RxD TxD+ Data+
2CTS TxD- Data-
3 TxD RxD+ -
4RTS RxD- -
5 SG SG -
RS-232 2-wire RS-485
RS-422 and
4-wire RS-485
5 4 32 1
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COM (DI-Wet)
DI0
DI1
DI2
DI3
DI4
DI5
DI6
DI7
GND
GND
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
GND
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
GND
GND
GND
GND
AI4+
AI4-
AI5+
AI5-
AI6+
AI6-
AI7+
AI7-
COM (DI-Wet)
DIO0
DIO1
DIO2
DIO3
DIO4
DIO5
DIO6
DIO7
GND
GND
GND
Rly0_C
Rly0_NO
Rly1_C
Rly1_NO
Rly2_C
Rly2_NO
Rly3_C
Rly3_NO
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
COM (DI-Wet)
DI0
DI1
DI2
DI3
DI4
DI5
GND
Rly0_C
Rly0_NO
Rly1_C
Rly1_NO
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
GND
GND
GND
GND
AO0+
AO0-
AO1+
AO1-
AO2+
AO2-
AO3+
AO3-
A B C D E
Before connecting the I/O terminal block, please refer to the user manual.
To change DI/DO jumper setting, disconnect the device from power, and open the casing
for modifying the jumper settings. Please refer to user manual for additional instructions.
10/100 BASE-T(X)
Pin 1 2 345678
Signal Tx+ Tx- Rx+ Rx-
RJ-45
Pin 2
DI
3
DI
4
DI
5
DI
6
DO
7
DO
8
DO
9
DOSignal
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing to avoid tripping.
■ Do not under any circumstances insert foreign objects of any kind into the heat
dissipation holes located on the different surfaces of the device. This may not
only harm the internal layout but might cause harm to you as well.
■ Do not under any circumstances open the device casing for any reason. Please
contact your dealer for any repair needed or follow the instructions on your
User’s Manual.
Field Maintenance and Service
Default Setting
Username: admin
Password: default
LAN1
10.0.50.100
255.255.0.0
10.0.0.254
IP address
Subnet mask
Default gateway
192.168.1.1
255.255.255.0
192.168.1.254
LAN2
IO5202-DB SeriesIO5202-TB Series
110 122.4 134.4
32.2
PWR RUN
TX RX
COM
LAN2LAN1
110 122.4 134.4
32.2
PWR RUN
TX RX
COM
LAN2LAN1
Top View
45
Side View
4.72
6.85 102.5
90
The warranty certification will not be effective without an authorized stamp issued
by Atop or an Atop overseas agent.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use within 3 months
after purchase, a sold product with defect shall be replaced with a new one. The
shipping cost from the customer to Atop will be reimbursed by Atop.
After 3 months and within the warranty period, Atop has sole discretion whether
to replace the unit with a new one; normally, as long as a product is under
warranty, all parts and labor are free of charge to the customer.
Three months after purchase, the shipping cost from the customer to Atop will
not be reimbursed, but the shipping cost from Atop to the customer will be paid
by Atop. After the warranty period, the customer shall cover the cost for parts
and labor.
RMA and Shipping Costs Reimbursement
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
Atop Customer Services and Support
Atop shall not be held responsible for any consequential losses from using Atop’s product.
Limited Liability
Warranty Period
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
PoE Injectors
Remote I/O
Ethernet Switches
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty Policy
Warranty Conditions
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of improper or unauthorized power supply, connectors, or parts/kits
(d) Replacement with unauthorized parts
2. Please report any problems via Atop’s website or email
[email protected]
www.atoponline.com

Other Atop I/O System manuals

Atop SE8502-M12 Series Manual

Atop

Atop SE8502-M12 Series Manual

Atop IO5202 Series Manual

Atop

Atop IO5202 Series Manual

Atop EH2308-PR Manual

Atop

Atop EH2308-PR Manual

Popular I/O System manuals by other brands

M-system R80 Series manual

M-system

M-system R80 Series manual

Allen-Bradley 5069-IF8 user manual

Allen-Bradley

Allen-Bradley 5069-IF8 user manual

Siemens Simatic S7-1500 manual

Siemens

Siemens Simatic S7-1500 manual

KonNad C2000-A2-SDD4040-AD1 user manual

KonNad

KonNad C2000-A2-SDD4040-AD1 user manual

Argus Security TAURUS TW-MO-SB-01 quick start guide

Argus Security

Argus Security TAURUS TW-MO-SB-01 quick start guide

ETAS ES5321.1 user guide

ETAS

ETAS ES5321.1 user guide

Pilz PSS u2 EF 2DO R 8A operating manual

Pilz

Pilz PSS u2 EF 2DO R 8A operating manual

Measurement Computing USB-3102 user guide

Measurement Computing

Measurement Computing USB-3102 user guide

National Instruments E Series Programmer's manual

National Instruments

National Instruments E Series Programmer's manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Masibus MAS-DI-16-D Series user manual

Masibus

Masibus MAS-DI-16-D Series user manual

GeoVision GV-NET/IO instruction manual

GeoVision

GeoVision GV-NET/IO instruction manual

SMC Networks EX600-SPR Series Operation manual

SMC Networks

SMC Networks EX600-SPR Series Operation manual

ABB Symphony Harmony Series instructions

ABB

ABB Symphony Harmony Series instructions

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Bose ControlSpace ESP-88 installation instructions

Bose

Bose ControlSpace ESP-88 installation instructions

Acces I/O products ETH-IDIO-16 user manual

Acces I/O products

Acces I/O products ETH-IDIO-16 user manual

Bosch FLM-420-I2-W installation guide

Bosch

Bosch FLM-420-I2-W installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.