10/100Base-T(X) Ethernet Pinouts
9-Pin Male D-sub Connector for RS-232/422/485
Pin
1DCD - -
2RxD TxD+ Data+
3 TxD RxD+ -
4DTR - -
5 SG SG SG
6DSR - -
7RTS RxD- -
8CTS TxD- Data-
9RI - -
RS-232 2-wire RS-485
RS-422 and
4-wire RS-485
9
5 4 32 1
8 7 6
5-Pin Terminal Block for RS-232/422/485
Jumper setting for DI/DO ( 8-4-0-0 model only)
2 x 10-Pin Terminal block for I/O
Pin
1RxD TxD+ Data+
2CTS TxD- Data-
3 TxD RxD+ -
4RTS RxD- -
5 SG SG -
RS-232 2-wire RS-485
RS-422 and
4-wire RS-485
5 4 32 1
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COM (DI-Wet)
DI0
DI1
DI2
DI3
DI4
DI5
DI6
DI7
GND
GND
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
GND
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
GND
GND
GND
GND
AI4+
AI4-
AI5+
AI5-
AI6+
AI6-
AI7+
AI7-
COM (DI-Wet)
DIO0
DIO1
DIO2
DIO3
DIO4
DIO5
DIO6
DIO7
GND
GND
GND
Rly0_C
Rly0_NO
Rly1_C
Rly1_NO
Rly2_C
Rly2_NO
Rly3_C
Rly3_NO
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
COM (DI-Wet)
DI0
DI1
DI2
DI3
DI4
DI5
GND
Rly0_C
Rly0_NO
Rly1_C
Rly1_NO
AI0+
AI0-
AI1+
AI1-
AI2+
AI2-
AI3+
AI3-
GND
GND
GND
GND
AO0+
AO0-
AO1+
AO1-
AO2+
AO2-
AO3+
AO3-
A B C D E
Before connecting the I/O terminal block, please refer to the user manual.
To change DI/DO jumper setting, disconnect the device from power, and open the casing
for modifying the jumper settings. Please refer to user manual for additional instructions.
10/100 BASE-T(X)
Pin 1 2 345678
Signal Tx+ Tx- Rx+ Rx-
RJ-45
Pin 2
DI
3
DI
4
DI
5
DI
6
DO
7
DO
8
DO
9
DOSignal
Top View
IO5202-DB-W Series
45
Side View
4.72
6.85 102.5
90
IO5202-TB-W Series
110 122.4 134.4
32.2
PWR RUN
TX
WLAN
RX
COM
LAN2LAN1
110 122.4 134.4
32.2
PWR RUN
TX
WLAN
RX
COM
LAN2LAN1
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only
harm the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on section
of your User’s Manual.
Field Maintenance and Service
Default Setting
Username: admin
Password: default
LAN1
10.0.50.100
255.255.0.0
10.0.0.254
IP address
Subnet mask
Default gateway
192.168.1.1
255.255.255.0
192.168.1.254
LAN2
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
shall be replaced with a new one within 3 months after purchase. The shipping
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Atop shall not be held responsible for any consequential losses from using Atop’s product.
Warranty Policy
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Warranty Conditions
RMA and Shipping Costs Reimbursement
Limited Liability
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Atop Customer Services and Supports
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Warranty Period
─ Any changes to this material will be announced on Atop website. ─
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
PoE Injectors
Remote I/O
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories