Autonics ARIO-C-CL User manual

ARIO-C-CL
CC-Link
User Manual ÊÊÊ MTO-ARIOCCLU1-V2.0-2200US


Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê5
Manual Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê7
Common Symbols in the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê9
Safety Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê11
1. Reference Manuals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê13
2. Overview of the ARIO-C-CL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê15
2.1. CC-Link Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê15
2.2. Unit Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê16
2.3. CC-Link Communication Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê18
2.4. Set the Transmission Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê19
2.5. Assign the Station Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê20
2.5.1. Assign the Station Number in the DAQMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê21
2.6. Connections of the Power Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê22
3. Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê23
3.1. LEDs for the Coupler Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê24
3.2. LEDs for the Field Network Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê26
4. Process Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê29
4.1. Memory Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê29
4.2. Data Processing in the Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê30
4.2.1. Check the Data of the Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê31
4.3. Example of the Process Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê32
4.3.1. Input Process Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê33
4.3.2. Output Process Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê33
4.3.3. Mapping of the Coupler Diagnostic Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê34
5. CC-Link Address Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê37
5.1. Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê37
5.2. CC-Link Memory Map Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê37
5.3. Memory Map of the ARIO Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê38
6. GX-Works2 Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê39
6.1. Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê39
6.2. Create a Mitsubishi PLC Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê41

6.3. Configure the CC-Link Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê44
6.3.1. General Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê44
6.3.2. Settings with CSP+. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê50
6.4. Download the Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê57
6.5. Monitor the I/O Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê59
7. DAQMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê63
7.1. Monitor the ARIO Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê63
7.2. Update the Firmware Version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê67
8. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê69
9. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê71
9.1. Electrical/Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê71
9.2. Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê72
10. Communication Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê73
10.1. CC-Link Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê73
10.2. ABUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ê73

Preface
Thank you for purchasing Autonics products.
Be sure to read and follow the Safety Precautions thoroughly before use.
This manual contains information about the product and how to use it properly, so keep it in a place
where users can easily find it.
Preface 5

6 Autonics | ARIO-C-CL

Manual Guide
•Use the product after fully reading the contents of the manual.
•The manual explains the product functions in detail and does not guarantee the contents other than
the manual.
•Any or all of the manual may not be edited or copied without permission.
•The manual is not provided with the product.
•Download and use from our website (www.autonics.com).
•The contents of the manual are subject to change without prior notice according to the improvement
of the product’s performance, and upgrade notices are provided through our website.
•We put a lot of effort to make the contents of the manual a little easier and more accurate.
Nevertheless, if you have any corrections or questions, please feel free to comment through our
website.
Manual Guide 7

8 Autonics | ARIO-C-CL

Common Symbols in the Manual
Failure to follow instructions may result in serious injury or death.
Failure to follow instructions may result in injury or product damage.
Supplementary explanation of the function
Example of that function
Important information about the feature
Common Symbols in the Manual 9

10 Autonics | ARIO-C-CL

Safety Considerations
Observe all 'Safety Considerations' for safe and proper operation to avoid hazards.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury
or substantial economic loss. (e.g., nuclear power control, medical equipment, ships, vehicles,
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire or economic loss.
2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct
sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or fire.
3. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
4. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
5. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
Caution
1. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or shortening the life cycle of the product.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire or electric shock.
3. When connecting the power input and output, use AWG 22-16 cable and check the connecting
method of crimp terminal.
Failure to follow this instruction may result in fire or malfunction due to contact failure.
4. Keep metal chip, dust, and wire residue from flowing into the unit.
Failure to follow this instruction may result in fire or product damage.
5. Do not connect or disconnect connector (terminal) wire or power, when the product is operating.
Failure to follow this instruction may result in fire or malfunction of the product.
Safety Considerations 11

Cautions during Use
1. Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
2. BUS power and I/O power should be insulated by the individually insulated power device.
3. Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
4. Use the rated standard cables and connectors. Do not apply excessive power when connecting or
disconnecting the connectors of the product.
5. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line and
shielded wire at input signal line. For stable operation, use shield wire and ferrite core, when wiring
communication wire, power wire, or signal wire.
6. Do not use near the equipment which generates strong magnetic force or high frequency noise.
7. Do not touch the module communication connector part of the base.
8. Do not connect, or remove the base while connected to a power source.
9. For removing the terminal, body or base, do not operate units for a long time without it.
10. This unit may be used in the following environments.
① Indoors (in the environment condition rated in ‘Specifications’)
② Altitude max. 2,000 m
③ Pollution degree 2
④ Installation category II
The specifications and dimensions of this manual are subject to change without any notice for product
improvement. Be sure to read and follow the considerations written in the instruction manual, other
manuals, and technical information on our Autonics website.
12 Autonics | ARIO-C-CL

1. Reference Manuals
Be sure to read the reference manuals below to use the product correctly and follow
the precautions written in these manuals.
You can download the reference manuals on our Autonics website.
Installation manual It contains information for you to setup and install the ARIO Unit.
1. Key features of ARIO Series
2. Environmental conditions and handling method for
installation
3. Installation precautions
4. Instructions about maintenance, etc.
1. Reference Manuals 13

Coupler manual It contains information for you to configure and use the coupler
in the field network.
1. Communication protocol overview
2. Hardware information: specifications, indicators, connection
diagram, and dimensions, etc.
3. Software information: process images, and mapping
information, etc.
Module manual It contains information on the modules provided by Autonics.
1. Hardware information: specifications, indicators, connection
diagram, and dimensions, etc.
DAQMaster user manual It contains information and usage guides on ARIO-related
functions supported by DAQMaster, the comprehensive device
management program.
1. Change properties of the coupler and modules
2. Module configuration via virtual mode
3. Check the address map of the Unit
4. Check the diagnostic information of the coupler
5. Update the firmware version of the coupler, etc.
14 Autonics | ARIO-C-CL

2. Overview of the ARIO-C-CL
2.1. CC-Link Protocol
CC-Link, one of the Fieldbus networks, is an industrial network composed of a topology of RS-485.
It supports the transmission distance of up to 100 meters at a transmission rate of 10 Mbps as well as
up to 64 stations with a high speed and deterministic data communication. The link scan time
supported by CC-Link can process the input signals of sensors that require a high-speed response or for
intelligent devices that require a large capacity of data communication. The data link system also
supports reducing wiring and costs for building a distributed system.
The ARIO-C-CL supports the CC-Link protocol. This coupler composes the physical structure of
connected modules and devices and creates input and output process images linked with the data of
CC-Link. The process images make it possible to experience a flexible installation environment, such as
the mixed arrangement of analog and digital modules.
2.1. CC-Link Protocol 15

2.2. Unit Descriptions
1. CC-Link Communication Connector It is a connector to connect with CC-Link master
station such as PLC.
For detailed information on the communication
cable, refer to the 2.3, “CC-Link Communication
Connector”.
2. DATARATE Rotary Switch It is a setting switch to set the transmission rate in
the CC-Link communication network.
For detailed information on setting the
transmission rate, refer to the 2.4, “Set the
Transmission Rate”.
3. Decimal Rotary Switches It is a setting switch to designate the station
number of the coupler in the CC-Link
communication network. You can also set the
station number in the DAQMaster.
For detailed information on addressing method,
refer to the 2.5, “Assign the Station Number”.
16 Autonics | ARIO-C-CL

4. CONFIG Port It is a port to connect to the PC where DAQMaster is
installed.
1. Port type: USB Type-B Micro
5. Indicators It displays the status of the coupler and
communication connection as shown below.
For detailed information on the indicators,
refer to the 3, Indicators.
1. Power and operating status of the coupler
2. CC-Link communication status
6. Power Supply Terminal It is a terminal block that supplies power to the
coupler and peripherals.
For detailed information on the device supply,
refer to the 2.6, “Connections of the Power
Terminal”.
7. Power Supply contacts It is a contact that feeds the power input from the
power supply terminal.
1. Top input contacts: feed the power supply for
the coupler, module, and ABUS to be operated.
2. Bottom input contacts: feed the power supply
for input and output signals of the connected
module.
2.2. Unit Descriptions 17

2.3. CC-Link Communication Connector
•Be sure to use the connector and cable approved by the CC-Link Partner Association
(CLPA).
The 5-pin PCB connector is used for the CC-Link communication connection.
For more information on the pin assignment, refer to the table below.
Pin no. Marking on the connector Color Description
1 DA: DATA A Blue RS-485 High signal
2 DB: DATA B White RS-485 Low Signal
3 DG: Data Ground Yellow Ground for RS-485 signal
4 SH: Shield - Shield
5 FG: Frame Ground - Frame Ground
18 Autonics | ARIO-C-CL

2.4. Set the Transmission Rate
•Be sure to use the connector and cable approved by the CC-Link Partner Association
(CLPA).
•Be sure not to exceed the maximum cable length of each transmission rate.
•The maximum overall cable distances are described based on the terminal resistor
110 Ω. For more information on the relationship between the cable distance and
terminal resistor, refer to the CC-Link specifications sheet.
Refer to the table below to set the transmission rate via the DATARATE rotary switch.
Be sure to set the transmission rate of the coupler the same as that of the CC-Link master station.
Number of
occupied stations 01)
Rotary switch
setting
Transmission
rate
Maximum
overall cable
distance
Automatic assignment
depending on the data size of the module
• Occupied stations: 1 to 4 stations
• Extended cyclic setting: 1, 2, 4, 8 times
0 156 kbps ≤ 1200 m
1 625 kbps ≤ 900 m
2 2.5 Mbps ≤ 400 m
3 5 Mbps ≤ 160 m
4 10 Mbps ≤ 100 m
• Occupied stations: 4 stations fixed
• Extended cyclic setting: 1 time
5 156 kbps ≤ 1200 m
6 625 kbps ≤ 900 m
7 2.5 Mbps ≤ 400 m
8 5 Mbps ≤ 160 m
9 10 Mbps ≤ 100 m
01) Refer to the 5.2, “CC-Link Memory Map Layout”.
2.4. Set the Transmission Rate 19

2.5. Assign the Station Number
•It is recommended to designate the station number of the coupler the same as the
value of the rotary switches.
•The station number cannot be applied while the coupler is operating.
•Be sure to start the coupler again to apply the changed station number.
You can assign the coupler’s station number via two decimal rotary switches.
Be sure to set the station number not to be duplicated with other stations considering occupied station
numbers in each station (slave stations of the data link).
Rotary switches (x10, x1) Station number
00 The station number assigned by the DAQMaster
01 to 64 1to 64
[Example] CC-Link system configuration
20 Autonics | ARIO-C-CL
Table of contents
Other Autonics I/O System manuals

Autonics
Autonics ARD-D Series User manual

Autonics
Autonics ARIO-C-MR User manual

Autonics
Autonics ADIO-EI User manual

Autonics
Autonics ARD-D Series User manual

Autonics
Autonics ARM Series User manual

Autonics
Autonics ARD Series User manual

Autonics
Autonics ARIO-C-EC User manual

Autonics
Autonics ARD-A Series User manual

Autonics
Autonics ADIO-PN User manual

Autonics
Autonics ADIO-PN User manual