PRECAUTIONS
Before attempting to connect or operate this product, please read these instructions completely:
1) Installed and maintained by qualified person as well as meet local codes.
2) Indoor designed dome camera must be used indoors but not outdoors of rainy, moist, etc).
3) Reinstalled or repaired over, must check resistance whether correct between circuit and shell part to confirm
insulation in order to avoid short-circuit.
4) Installing holder should withstand four dome units weight.
This mark refers to the dangerous voltage
This mark refers to the operations &
maintains must be directed
WIRES SUGGESTED
2 2 2 2
Diameter of Line 0.5mm (20#) 1.0mm (18#) 1.5mm (16#) 2.5mm (14#)
72W Power-supply (indoor dome) 25M(94ft) 45M(150ft) 70M(238ft) 110M (380ft)
72W Power-supply (outdoor dome) 10M(37ft) 18M(60ft) 28M(95ft) 45M (152ft)
Cable Models Max. Distance Cable Models Max. Distance
75-2 150M 75-5 ≈370M
75-3 ≈M 75-7 ≈500M
75-4 ≈270M 75-9 ≈700M
200
2) Video cable requirements:
1) 24V power line distance & requirements:
Notes:same model cables have differences by manufacturers, above numbers are the commons.
Product and instruction includes below marks:
These serial integrated dome cameras apply for bank, airport, traffic, government, electric power, prison, hostel,
commercial building, plant, school, museum, etc.
High-performance DSP designs with strong stability.
Built-in lossless data setting of power-off
RS-485 bus control
Manual/auto tour control coordinates with camera zoom ratio, proportional speed-down, stable operation, exact position.
128(255) preset positions randomly store, exactly position.
6 tour routes, preset-points interval time adjustable (adjusted by customer, high speed domes fitted).
Horizontal 360° endless rotate no blind zone.
Automatically vertically 180° endless flip. (High speed domes fitted)
Auto iris, auto focus and auto white balance
WDR function: suit complex light environments.
Night vision function: automatically adjust CCD luminance according to ambient light intensity changes (day/night models
fitted).
Backlight compensation function: in strong light conditions can see all objects.
Precise motor drives, operate stably, control sensitively, low consumption, low noise.
Standard alarm-in/out port, preset position links alarm-in.
All-in-one design, concise structure, high reliable
(Some models support this function)
INTRODUCTIONS
FEATURES
- 1 -

DOME SPECIFICATIONS
Notes:we stress development, parameters upgrade without notification
OPERATION
SONY, CANON, CNB, SAMSUNG
At 8-digit and 6-digit switchers set dome ID, baud rate and control protocol; Connect 485 line and AC wire.
Virgin dome is powered-on, motherboard indicator light flickers fast, then shut, horizontally (pan) rotate 2 circles,
vertical (tilt) rotate and stop at 0°position, till now the motherboard indicator light shines, dome camera enters normal
work state (light flickers every 2 minute).
Fitted cameras:
Preparation:
Power-on for self test:
Models High speed dome Middle speed dome
Pan Rotation Range 360° random
Pan Speed 0.5~300°/s 0.5~180°/s
Tilt Rotation Range 0~90°; 180° auto flip 0~90°
Tilt Speed 0.5~300°/s 0.5~100°/s
Communication RS485
Preset Positions 128(255) units
Tour routes 6 defaults routes
Power Supply AC24V
Power Consumption 20W(indoor models) / 40W(outdoor models)
Operation Temperature -30~55℃(Indoor Types)/ -30~65℃(Outdoor Types)
Step by the below:
1) Use keypad input camera number of preset position, press CAMERA to select camera.
2) Operate joystick, zoom button, focus button to adjust image.
3) Input specified preset position number, press SET button to save preset scene parameters.
Keyboard CALL button allows you call out and see preset cameras image. The follow steps show how to view these
preset positions:
1) Use keypad input camera number of the called, press CAMERA button to select camera.
2) Input number of preset position of the called, press CALL button, camera turns to the specialized position. Lens
zoom, focus and iris auto convert to the preset parameters. The image of preset camera displays on monitor.
Preset position setting (1#~64#; 101#~255#):
Call preset positions (1#~64#; 101#~255#):
Zoom-in or zoom-out lens to get featured images or wide-angle images. Hold on pressing TELE button, objects being
closer, object image larger gradually. Hold on pressing WIDE button, objects being farther, object image smaller
gradually.
If you quickly press and release zoom button, monitor image only changes a little. Image changes degree depends on
the lasting time of holding zoom button.
Long-focus lens and wide angle lens (zoom control):
After selecting one dome, can manually control dome rotation by joystick on keyboard. Joystick lead dome rotating
with three kinds of moving: up-down, left-right, diagonal line
Control dome full directions rotation:
Focus is a process of adjusting image clarity. Hold on pressing FAR button, far objects turn clear, and near objects
turn vague. Hold on pressing NEAR button, near objects turn clear, far objects turn vague. Adjust focus buttons until
monitor image turns clear. The same with ZOOM button, focus changes degree depends on the lasting time of holding
focus buttons.
Lens focus control:
- 2 -

In accordance with current lens multiples auto adjust speed of rotation.
High speed domes support 8-channel alarm input and 2-channel alarm output (middle speed dome serials cameras
support 2-channel alarm-input and 1-channel alarm-output). 1# alarm matches with 101# preset position; 2# alarm
matches with 102# preset position; 8# alarm matches with 108# preset position. Any channel alarms, 2 channels relays
alarm; call 100# preset position, then relays stop outputting.
After settling start-point and end-point, scan begins with clockwise direction until to the end-point, then scan back
from end-point to start-point. By this way scanning till receiving any command (as sheet below):
Proportional speed-shift:
Alarm linkage: (optional function)
Point-to-point constant scanning:
Attached chart: command list for dome and camera (all dome models fitted)
Notes: ¤” means this function Available; “ N means Not Available“ A ”
Preset Position
Number
Call Preset Positions
Set Preset Position
Dome/Camera Control Content
65 Run first route (Sequential scan of 1#~16# preset positions) ¤ NA
66 Run second route (Sequential scan of 17#~32# preset positions) ¤ NA
67 Run third route (Sequential scan of 33#~48# preset positions) ¤ NA
68 Run fourth route (Sequential scan of 49#~64# preset positions) ¤ NA
69 Run fifth route (Sequential scan of 101#~128# preset positions) ¤ NA
70 Run all sequential scans of confirmed preset positions ¤ NA
71 Clockwise 360°scan (low speed) ¤ NA
72 Clockwise 360°scan (middle speed) ¤ NA
73 Clockwise 360°scan (high speed) ¤ NA
74 Anti-clockwise 360°scan (low speed) ¤ NA
75 Anti-clockwise 360°scan (middle speed) ¤ NA
76 Anti-clockwise 360°scan (high speed) ¤ NA
77 Set duration time of preset position ¤ ¤
78 Zero calibration ¤ NA
79 Mirror Off On
80 Screen Display Off On
81 Digital zoom Off On
82 Color Off On
83 Backlight compensation Off On
84* Manually switch ICR Off On
85 Negative image Off On
86* Auto switch ICR Off On
87 White balance mode Manual Auto
88 View state of dome ¤ NA
89 Exposure mode Manual Auto
90 Focus mode Manual Auto
91 Back to Factory Settings ¤ NA
92 Call menu ¤ ¤
93 View version of dome ¤ NA
94 Eliminate single preset position (Once more within 5 seconds) ¤ NA
95 Eliminate all preset positions (Once more within 5 seconds) ¤ NA
96 Run linear scan / Set start of linear scan ¤ ¤
97 Set end of linear scan NA ¤
100 Shut alarm-output (be sure alarm-output exists)
¤ NA
Supplement:
Items SONY CANON CNB SAMSUNG
Preset Position Range 1~255 1~128 1~255 1~255
Preset Position Lasting (
Image Vertical-Flip(V-FLIP) √
91 Command
√92#command) √(77#command) × 77#command)
Period Setting
× × ×
#×√× ×
77# detention-time setting is similar to 92#
Cautions: This manual does not introduce setting methods of detail camera menus. If you want to change
camera parameters, please contact to dealer and ask for setting instructions of menus.
- 3 -
Set 92#, screen displays camera menu; call 92# or select EXIT button leaving menu. In menu state, WIDE, TELE,
NEAR and FAR means up, down, enter submenu and go back higher level menu. For setting parameter, NEAR and FAR
can increase or decrease numeral value. For Samsung cameras, OPEN and CLOSE are confirm buttons.
92# menu operation:

Φ
1
2
Dimensions
Indoor ceiling-mount dome Indoor wall mount dome Outdoor dome
152
100
140
114
200
170
4- 8
154
11 3
256
209
64
7
G1 1
2
4-
390
Φ9
226
200
G1 1
2
G1 1
2
Φ7
4-
G11
2
Φ1 0 0
4 - 10
140
165
209
9 3
55
310
113
154
165
209
B N - B 5 6 0 6 C B N - B 5 6 0 6 B B N - B 5 6 0 6 E
G1 1
2G1 1
2
526
500
Φ
40
120
BN-B5606Q BN-B5606D
Integrated Speed Dome Camera Specifications
Image Sensor 1/4" SONY 1/4" SONY 1/4" SONY 1/4" SONY 1/4" SONY
Super HAD CCD Super HAD CCD Ex-view CCD Ex-view CCD Ex-view CCD
Horizontal Resolution 480TV Lines 480TV Lines 480TV Lines 480TV Lines 530TV Lines
Day/Nigh Function Manual/ Auto No Manual/ Auto Manual/ Auto Manual/ Auto
(ICR Filter) (ICR Filter) (ICR Filter)
Min. illumination Color:1Lux Color:1Lux Color:0.7Lux Color:1Lux Color:1.4Lux
B/W:0.01Lux B/W:0.002Lux B/W:0.01Lux B/W:0.1Lux
Optical Zoom 22x,f=4~88mm 18x,f=4.1~73.8mm 18x,f=4.1~73.8mm 26x,f=3.5~91mm 36x,f=3.4~122.4mm
Digital Zoom 10x 12x 12x 12x 12x
Video System PAL/NTSC PAL/NTSC PAL/NTSC PAL/NTSC PAL/NTSC
Wide Dynamic Range No No No No With
Privacy Function No 24 Zone 24 Zone 24 Zone 24 Zone
Total Pixel 795(H)×596(V)
Effective Pixel 752(H)×582(V)
Sync System Internal
Video Output 1.0V (p-p), 75 ohms, BNC
S/N Ratio >50dB
Built-in Module CANON SONY FCB-EX45CP SONY FCB-EX480CP SONY FCB-EX980P SONY FCB-EX1010P
Indoor Ceiling-mount Dome (High speed) BN-5606HH0 BN-5606LH0 BN-5606XH0 BN-5606NH0 BN-5606EH0
Indoor Wall mount Dome (High speed) BN-5606HH2 BN-5606LH2 BN-5606XH2 BN-5606NH2 BN-5606EH2
Outdoor Wall mount Dome (High speed) BN-5606HH3 BN-5606LH3 BN-5606XH3 BN-5606NH3 BN-5606EH3
Indoor Ceiling-mount Dome (Middle speed) BN-5606HM0 BN-5606LM0 BN-5606XM0 BN-5606NM0 BN-5606EM0
Indoor Wall mount Dome (Middle speed) BN-5606HM2 BN-5606LM2 BN-5606XM2 BN-5606NM2 BN-5606EM2
Outdoor Wall mount Dome (Middle speed) BN-5606HM3 BN-5606LM3 BN-5606XM3 BN-5606NM3 BN-5606EM3
Image Sensor 1/4" SONY 1/4" SONY Interline 1/4" SONY 1/4" Double Density 1/4" Double Density
Super HAD CCD Transfer CCD Super HAD CCD Interline Transfer Interline Transfer
Horizontal Resolution 480TV Lines Color:540TV Lines Color:550TV Lines Color:550TV Lines Color:550TV Lines
B/W:570TV Lines B/W:680TV Lines B/W:680TV Lines B/W:680TV Lines
Day/Nigh Function Manual/ Auto Manual/ Auto Manual/ Auto Manual/ Auto Manual/ Auto
(ICR Filter) (ICR Filter) (ICR Filter) (ICR Filter) (ICR Filter)
Min. illumination Color:1Lux Color:0.4Lux Color:0.4Lux Color:0.7Lux Color:0.7Lux
B/W:0.1Lux B/W:0.1Lux B/W:0.02Lux B/W:0.03Lux B/W:0.06Lux
Optical Zoom 27x,f=3.6~97.2mm 30x,f=3.3~99mm 33x,f=3.5~115.5mm 33x,f=3.5~115.5mm 37x,f=3.5~129.5mm
Digital Zoom 10x 10x 12x 12x 12x
Video System PAL/NTSC PAL/NTSC PAL/NTSC PAL/NTSC PAL/NTSC
Wide Dynamic Range No No No Wit h With
Privacy Function No 32 Zone 8 Zone 8 Zone 8 Zone
Total Pixel 795(H)×596(V)
Effective Pixel 752(H)×582(V)
Sync System Internal
Video Output 1.0V (p-p), 75 ohms, BNC
S/N Ratio >50dB
Built-in Module CNB M2760PDL SAMSUN SDM-310 SAMSUN SDM-332 SAMSUN SDM-335 SAMSUN SDM-375
Indoor Ceiling-mount Dome (high speed) BN-5606QH0 BN-5606TH0 BN-5606UH0 BN-5606WH0 BN-5606GH0
Indoor Wall mount Dome (high speed) BN-5606QH2 BN-5606TH2 BN-5606UH2 BN-5606WH2 BN-5606GH2
Outdoor Wall mount Dome (high speed) BN-5606QH3 BN-5606TH3 BN-5606UH3 BN-5606WH3 BN-5606GH3
Indoor Ceiling-mount Dome (middle speed) BN-5606QM0 BN-5606TM0 BN-5606UM0 BN-5606WM0 BN-5606GM0
Indoor Wall mount Dome (middle speed) BN-5606QM2 BN-5606TM2 BN-5606UM2 BN-5606WM2 BN-5606GM2
Outdoor Wall mount Dome (middle speed) BN-5606QM3 BN-5606TM3 BN-5606UM3 BN-5606WM3 BN-5606GM3
Slow Shutter: 0.001 Lux Slow Shutter: 0.0006 Lux
- 4 -

EMBEDDED DOME INSTALLATION
Step 1: drill a hole on ceiling Step 2: install embedded bracket
Step 3: set dome
Set dome bottom DIP switcher (SW1 and SW2) to
confirm control-protocol and dome address, similar
with label setting or switcher setting.
At the installation center of ceiling drill a hole of
3 m m d i a m e t e r, i n p u t s e l f - t r a p p i n g s c r e w t o
positioning-ruler hole, and then fix it on ceiling.
Use pencil and positioning-ruler drawing a circle,
dig away stuff.
Press embedded-bracket fixture, input fixture input
hole of ceiling until wholly entering. Unwrap the three
fixtures, tighten screw, and confirm that embedded-
bracket has already been fixed on ceiling.
Notes: embedded-bracket and ceiling must link
with steel belt so as to avoid dome dropping. The steel
belt should be offered by customer.
Power supply
24VAC
AC 1
GND
AC 2
RX+
RX-
Control signal
Monitor or other
video-input
devices
RS-485(Pelco)
Video out
CEILING MOUNT DOME INSTALLATION
Power line
Video line
Control line
Turn
According to bracket hole size, use pencil and
positioning-ruler drawing a circle (Φ40mm), dig away
stuff.
At the edge of circle, drill 3 holes (Φ6mm) matched
with 3 holes of bracket, then fill M6 anchor-screws on
each hole (anchor-screws are offered by customer).
Insert anchor-screws to 3 holes and fasten them
with pad & nut.
Insert 3 screw units into the
upper bracket hole, just like the
picture directing, confirm all
screws are tightened in locating
slot.
Connect video cable,
power line and control line with
mechanical module. As picture
directing.
Step 4: connect to mechanical module wiring
Step 1: open hole on ceiling Step 2: fix ceiling-mount bracket
Step 5: install dome
- 5 -

Step 3: set dome
Power supply
24VAC
AC 1
GND
AC 2
RX+
RX-
Control signal
Monitor or other
video-input
devices
RS-485(Pelco)
Video out
Set dome bottom DIP switcher (SW1 and SW2) to
confirm control-protocol and dome address, similar
with label setting or switcher setting.
Step 4: connect to mechanical
module wiring
Step 5: install dome
Connect video cable, power line and control line with
mechanical module. As picture directing.
Insert 3 screw units into the upper bracket hole,
just like the picture directing, confirm all screws are
tightened in locating slot.
Control line
Power line
Video line
Step 1: install outer shell
WALL MOUNT DOME INSTALLATION
Cautions: if it is outdoor installation, should confirm the sealing quality, and avoid approaching heat or moisture. As
variability of bracket type & installation, here only introduce installation method and steps of dome. But for bracket
installation, please refer to related instructions.
a. Video cable, power line and control line penetrate wall-mount
bracket until stretch out.
b. Then they penetrate outer shell hole until stretch out enough length.
c. As the picture, hang outer shell on bracket, screw-thread is sealed
with waterproof materials.
Turn
Step 2: install dome
a. Set dome bottom DIP switcher (SW1 and SW2) to confirm control-protocol and dome address, similar with label
setting or switcher setting.
b. Connect video cable, power line and control line with mechanical module. Then put and fasten mechanical module
into shell. As picture directing
Power line
Video line
Turn
Control line
- 6 -

Step 3: install transparent cap
Bolt one end of safety rope of transparent cover
to the screw bolt of outer shell. Take off 2 screws of
outer shell edge. Closely connect fixing hole of
transparent cover with screw hole of outer shell,
confirm matched holes directing to each other
exactly and transparent cover has been attached on
outer shell. Finally put and fasten 2 steel screws in
order to fix transparent cover.
Cautions: ahead of transparent-cover-cap covered
down, must connect well the power socket of
heater.
Video line
AC24VRed:
AC24VBlack:
Green: RS 485+
Yellow: RS 485-
ERRORS & SOLUTIONS
Errors Descriptions
Powered on, but no
reaction, no image and
no indicator shining
Powered on, self-test
well, having image, but
out of control
Fail to finish self-test,
having image but with
motor hums
Image Unstable
Image Vague
Dome control of stop
failed or delayed
Switch image with
vertical rolling on
monitor
If one power line links multiple domes (centralized power
supply). 24V AC connector should be linked with same
direction. Each connector end should connect to 24VAC
connector terminal; so do the other end and terminal
Dome power 1
Dome power 2
Dome power 3
Possible Reasons Solutions
Power line connection incorrect Revise
Power source damaged Replace
Fuse tube broken Replace
Power line contact poor Remove poor contact
Dome address & baud-rate setting wrong Reset dome address code & baud rate
Protocol wrong Revise
RS485 line connection inverted or open-circuit Check connection of RS485 control line
Mechanical errors Examine & repair machine
Camera slope Place well
Power inadequate Replaced with proper power supply, near to camera for better
Video circuit contact poor Remove poor contact
Power inadequate Replace
Focus by manual Operate dome or call any preset position
Dome shell dirty Clean shell
Dome power inadequate Replaced with proper power supply, near to camera for better
Check whether controlling-resistance of farthest
dome is added
Add proper resistance for farthest dome
Dome phase is wrong
MAINTAIN
1.
~±
Please accord to operating environments.
2. Do not let dome direct to strong light objects.
No matter in working or not working, dome MUST NOT direct to the sun and other objects with strong light.
Otherwise, CCD maybe damaged permanent.
3. Do not install indoor dome in outdoor environments.
4. Electric safety, lightning proof, surge proof
In process of using this products, should accord to each item of electric safety criteria. Dome and signal line must be
at least 50 meters away from high voltage equipments & lines. If it is hard to meet the above requirements, please adopt
steel tube to wrap signal line, besides set some grounding for steel tube;
Outdoor type speed domes can prevent equipments being destroyed by under 0 4000W lightning strike, surge
and other suchlike pulse signals.
5. Transparent cover cleaning
In order to ensure dome image clear, transparent cover should timely cleaned. When cleaning, we should only hold
outer ring of transparent cover, but not directly touch the cover, otherwise acid sweat will erode the cladding material of
glass surface, moreover other rigid substance can also scratch the cover, causing image vague. So you’d better use
soft enough materials (i.e. cloth). As for serious stains, both neutral detergent and other high-quality personal
detergents are suitable.
- 7 -

6. Careful transport
Transport & storage process should avoid heavy press, intense shock and soak. This product should adopt
integrated packing transport, no matter dealer’s shipping or return to plant repairing, the damage caused by transport
method is beyond guaranty range.
7. Careful installation
Transparent cover belongs to advanced optical products, should avoid be directly touched to scratch surface and
harm image quality. Before thorough installation please do not power on.
8. Do not disassemble
Inner dome there is no DIY repaired components. The repair work must be finished by our technical staff.
ID(SW1)
5 6
1200BPS 0 0
2400BPS 1 0
4800BPS 0 1
9600BPS 1 1
ID(SW1)
1 2 3 4
PELCO-D 0 0 0 0
PELCO-P 1 0 0 0
B01 0 1 0 0
ALEC 1 1 0 0
KALATEL 0 0 1 0
LILIN 1 0 1 0
VICON 0 1 1 0
Panasonic 1 1 1 0
DAHUA 0 0 0 1
Santachi 1 0 0 1
Philips 0 1 0 1
AD 1 1 0 1
Reserved 0 0 1 1
Reserved 1 0 1 1
Reserved 0 1 1 1
Reserved 1 1 1 1
CHART OF SWITCHER SETTING
Chart A. Setting ( Baud Rate Switcher 1)
Chart B. Protocol Setting (Switcher 1)
1=ON; 0=OFF
1=ON; 0=OFF
Baud Rate
Protocols
- 8 -

Char t C. Address Setting( )Switcher 2
Address
Number
Address
Number
Address
Number
Address
Number
ID(SW2)
12345678
ID(SW2)
12345678
ID(SW2)
12345678
ID(SW2)
12345678
1 10000000 33 10000100 65 10000010 97 10000110
2 01000000 34 01000100 66 01000010 98 01000110
3 11000000 35 11000100 67 11000010 99 11000110
4 00100000 36 00100100 68 00100010 100 00100110
5 10100000 37 10100100 69 10100010 101 10100110
6 01100000 38 01100100 70 01100010 102 01100110
7 11100000 39 11100100 71 11100010 103 11100110
8 00010000 40 00010100 72 00010010 104 00010110
9 10010000 41 10010100 73 10010010 105 10010110
10 01010000 42 01010100 74 01010010 106 01010110
11 11010000 43 11010100 75 11010010 107 11010110
12 00110000 44 00110100 76 00110010 108 00110110
13 10110000 45 10110100 77 10110010 109 10110110
14 01110000 46 01110100 78 01110010 110 01110110
15 11110000 47 11110100 79 11110010 111 11110110
16 00001000 48 00001100 80 00001010 112 00001110
17 10001000 49 10001100 81 10001010 113 10001110
18 01001000 50 01001100 82 01001010 114 01001110
19 11001000 51 11001100 83 11001010 115 11001110
20 00101000 52 00101100 84 00101010 116 00101110
21 10101000 53 10101100 85 10101010 117 10101110
22 01101000 54 01101100 86 01101010 118 01101110
23 11101000 55 11101100 87 11101010 119 11101110
24 00011000 56 00011100 88 00011010 120 00011110
25 10011000 57 10011100 89 10011010 121 10011110
26 01011000 58 01011100 90 01011010 122 01011110
27 11011000 59 11011100 91 11011010 123 11011110
28 00111000 60 00111100 92 00111010 124 00111110
29 10111000 61 10111100 93 10111010 125 10111110
30 01111000 62 01111100 94 01111010 126 01111110
31 11111000 63 11111100 95 11111010 127 11111110
32 00000100 64 00000010 96 00000110 128 00000001
Address
Number
Address
Number
Address
Number
Address
Number
129 10000001 161 10000101 193 10000011 225 10000111
130 01000001 162 01000101 194 01000011 226 01000111
131 11000001 163 11000101 195 11000011 227 11000111
132 00100001 164 00100101 196 00100011 228 00100111
133 10100001 165 10100101 197 10100011 229 10100111
134 01100001 166 01100101 198 01100011 230 01100111
135 11100001 167 11100101 199 11100011 231 11100111
136 00010001 168 00010101 200 00010011 232 00010111
137 10010001 169 10010101 201 10010011 233 10010111
138 01010001 170 01010101 202 01010011 234 01010111
139 11010001 171 11010101 203 11010011 235 11010111
140 00110001 172 00110101 204 00110011 236 00110111
141 10110001 173 10110101 205 10110011 237 10110111
142 01110001 174 01110101 206 01110011 238 01110111
143 11110001 175 11110101 207 11110011 239 11110111
144 00001001 176 00001101 208 00001011 240 00001111
145 10001001 177 10001101 209 10001011 241 10001111
146 01001001 178 01001101 210 01001011 242 01001111
147 11001001 179 11001101 211 11001011 243 11001111
148 00101001 180 00101101 212 00101011 244 00101111
149 10101001 181 10101101 213 10101011 245 10101111
150 01101001 182 01101101 214 01101011 246 01101111
151 11101001 183 11101101 215 11101011 247 11101111
152 00011001 184 00011101 216 00011011 248 00011111
153 10011001 185 10011101 217 10011011 249 10011111
154 01011001 186 01011101 218 01011011 250 01011111
155 11011001 187 11011101 219 11011011 251 11011111
156 00111001 188 00111101 220 00111011 252 00111111
157 10111001 189 10111101 221 10111011 253 10111111
158 01111001 190 01111101 222 01111011 254 01111111
159 11111001 191 11111101 223 11111011 255 11111111
160 00000101 192 00000011 224 00000111 256 00000000
ID(SW2)
12345678
ID
12345678
(SW2) ID
12345678
(SW2) ID
12345678
(SW2)
Char t C. Address Setting( )Switcher 2
- 9 -
This manual suits for next models
2
Table of contents