7
1. Scope of delivery
1x Air circulation fan ARIZONA
2x chain with snap hook
2x V-hook
2. Technical data
Apparatus type: ARIZONA
Power supply: 230 V ~ / 50-60 Hz
Power: 40 Watt
Air circulation: 460 m³/h
Protection category: I
Protection class: IP X4
IMPORTANT:
Familiarise yourself with and observe these operating instructions and the general safety and hazard
notes before installation. Keep this document in a safe place for future reference. If you have any
doubts about the safety of the apparatus, please consult a qualified technician. When installing in a
greenhouse, please ensure that the electrical connections are made by a qualified electrician.
3. General
After unpacking and before commissioning, ensure that the apparatus and all the accessories are in
good working order. In case of transport damage, please contact the responsible distributor or the
manufacturer immediately. Keep packaging material (polybags, polystyrene, nails etc.) out of reach of
children, since such materials can pose a hazard.
The ARIZONA electrical air circulation fan provides even and also energy-saving ventilation in
greenhouses and winter gardens. It is simple to operate and requires very little installation space. This
apparatus is certified for connection to 230 V ~ / 50-60 Hz AC only. It must be protected against heavy
soiling and moisture. Any use other than that described above may damage the apparatus and also
carries a risk of short circuits, fire, electric shock, etc. It is imperative that the safety and installation
instructions are followed.
EN

Air circulation fan ARIZONA
8
4. Safety and hazard notes
•Use only a public utility 230 V ~, 50/60 Hz mains socket outlet as power supply. Never attempt to
operate the apparatus with a different voltage.
•If you are unsure about operation, safety or connection of the apparatus, please consult a qualified
technician.
•This apparatus is for indoor use only.
•The apparatus must be unplugged from mains before opening the cover or removing components.
•Never plug into mains or unplug if your hands are wet.
•Never pull on the power cable, pull the plug only by gripping it by the surfaces provided.
•Never install the apparatus near taps, basins or other sources of water. Also never connect your
apparatus to a power supply if the surface of the fan is moist.
•Do not insert objects into the openings of the apparatus. Risk of injury, electric shock or damage to
the apparatus!
•When installing, ensure that the connecting lead is not crushed or damaged by sharp edges. If this
should damage the insulation, the apparatus must under no circumstances be connected to
mains. Life-threatening!
•Always pull the mains plug before cleaning the apparatus. Clean only with a moist (not wet) cloth.
•Always pull the mains plug if the apparatus will not be used for a length of time. During this time,
store the apparatus in a protected and dry place.
•If it is likely that the apparatus can no longer be safely operated, it must be decommissioned and
protected against accidental operation. This is the case:
- if the apparatus or mains cable are visibly damaged
- if the apparatus has stopped working
- after extended storage in unfavourable conditions
- after serious transport stress
•Apparatus operating with mains voltage must be kept away from children.
•The apparatus is not suited for use in areas used for animal husbandry.
•These operating instructions are part of the apparatus and should be kept in a safe place. If the
apparatus is passed on to third parties, it must be accompanied by these operating instructions.
•In industrial facilities, the Accident Prevention Regulations for Electrical installations and Operating
Materials of the Industrial Employer’s Liability Insurance Association are to be observed.
•Never spill fluids on the apparatus. There is a danger of fire or lethal electric shock. If this should
nevertheless transpire, unplug the mains and consult a qualified technician.
•Should you be unsure about the proper connection or should any questions arise that are not dealt
with in the operating instructions, please contact the manufacturer or a qualified technician.
•This apparatus may neither be operated by persons (including children) with limited physical,
sensory or mental faculties nor by persons who are not sufficiently experienced or adequately
knowledgeable in the use of the product, unless such persons are supervised or instructed in the
use of the apparatus by a person responsible for their safety.

Air circulation fan ARIZONA
9
5. Installation
In damp rooms, electrical apparatus may only be operated from residual current protected sockets!
Before operating the apparatus, ensure that this is the case where it is to be installed.
Ensure that the air circulation fan is not connected to mains before or during installation. Select the
place for installation to prevent any possibility of exposure to rain or falling into water.
Lay the connecting cable in a manner not posing a stumbling hazard and so that it cannot be crushed
or come into contact with hot surfaces. Use only extension leads matched to the power rating of the
apparatus and complying with the applicable safety regulations.
Hanging installation:
To use the ARIZONA air circulation fan as a hanging device, the supplied chains must first be fitted.
The following supplied components are required for assembly:
2x ARIZONA hanging chains
2x V-hooks
The ARIZONA fan is supplied with metal eye bolts on the housing to hook the chains via the snap
hooks. Then hook the V-hooks into the other two snap hooks. These V-hooks are then fastened to the
profiles of your greenhouse.
Your ARIZONA air circulation fan is now ready to use as a hanging fan.
Note:
When selecting the installation site, ensure that the airflow is unobstructed. The distance between the
wall and the back air intake must be at least 250 mm and at least 500 mm from the front of the fan.
Ensure that the fan intake and outlet are not blocked by any objects (e.g. plants).
6. Operation
To start up the ARIZONA air circulation fan, plug it into any 230 V ~ 50/60 Hz AC socket. The fan
immediately starts circulating the air.
Pollination promotion:
The air circulation fan can promote plant pollination during flowering. Constant air circulation
distributes pollen throughout the area.
Cooling the greenhouse:
On hot summer days, high temperatures above average occur in your greenhouse - not suited for all
plant species. The ARIZONA air circulation fan can vent excess heat to the outside. Clearly cooler
conditions can be achieved in conjunction with open doors and skylights.
RECOMMENDATION:
For particularly effective and pleasant ventilation, we recommend the Bio Green thermostat Thermo 2
(Order no. TER2). This activates the fan automatically when your selected temperature is exceeded.
And it switches off when the corresponding cooling has been achieved.

Air circulation fan ARIZONA
10
7. Cleaning, repairs and disposal
•Do not use abrasive or caustic cleaning agents.
•Before cleaning, switch off the apparatus and allow it to cool down for about 30 min. before
starting to clean.
•Clean the enclosure with a damp (not wet) cloth, vacuum cleaner or feather duster.
•Never submerge the apparatus in water.
•Take the material to be disposed of to an appropriate waste disposal point.
•The apparatus may only be repaired by authorised specialists. Please therefore contact the
manufacturer or distributor in this regard.
•Attention! The guarantee is null and void in cases of improper repairs.
•Inappropriate repairs pose a hazard to the user and other persons.
8. Warranty and servicing
We offer you a 2-year unlimited manufacturer’s warranty (effective from the date of purchase) on all
Bio Green products. Damages arising from external force, improper use as well as non-observance of
cleaning and servicing and operating instructions are excluded under this warranty.
Important note
The apparatus may only be opened and repairs may only be carried out by authorised specialists, in
due consideration of the applicable repair instructions. Only original components may be fitted.
The guarantee for proper operation and operating safety can only be honoured if the apparatus is
properly installed and handled. This also applies with respect to statutory provisions for technical
working materials as well as applicable accident prevention regulations.
For warranty claims, please complete the enclosed warranty and info card!
Please contact our BioGreen Service should you have any further questions:
Tel.: +49 (0)6444 / 9312-0
info@bio-green.eu
Other manuals for ARIZONA
1
Table of contents
Other Bio Green Fan manuals
Popular Fan manuals by other brands

Hunter
Hunter Type 2A Models Owner's guide and installation manual

Air King
Air King AKLC701 Specifications

Ebmpapst
Ebmpapst R4D310-AS18-01 operating instructions

Air King
Air King Builder’s Choice 9842 Specifications

Ebmpapst
Ebmpapst 4656 EAU-003 operating manual

Ebmpapst
Ebmpapst W2E250-CM06-01 operating instructions