Version: 1 Page 6 of 16
5. General maintenance instructions
1. Maintenance, service and cleaning works may only be realized when the
tractor and mower are completely stopped/off (switch key off). In any
case, use adequate supports (brackets) under the mower, in order to avoid
an intentional endangerment by lowering.
2. By initial commission, check the firm seat of the screws after 30 minutes and
tight them again, if necessary! Check them regularly efore every
application.
3. Before the first operation, check the oil level in the gear, and refill gear oil
SAE 80-90 up to the control point, if necessary.
4. The center gear (R60EX) requires 1,1 liter SAE 80-90 gear oil, the outer gears
(M55VEX) require 1,2 liter each.
5. The first oil change should be effected after 50 operational hours.
6. If works have to be carried out under the mower, adequate supports
(brackets) are required.
7. By oil change or removing lubricants one must pay attention that the
lubricants will be disposed properly.
8. Damaged blades must be replaced immediately, since damages may be
caused by imbalance.
9. The blades may only be replaced or repaired by a workshop which is
authorized by the manufacturer, since otherwise it will result into immediate
expiration of any guarantee claim.
10. Use only original spare parts of BRAUN, since otherwise any guarantee
claim expires.
11. The lubrication nipples of the main bearing have to be lubricated only 1-2
strokes per week. Before that the shafts have to be cleaned (see picture 2,
position 8).
12. Effect the maintenance of the oint shaft according to manufacturer’s
instructions.
13. Apply adherent graphite spray to the oint shaft every 30 operational hours
or lubricate with Molykote grease and let it dry.
14. Clean the mower after each application, in order to avoid that the
herbage will dry onto the slip planes.
15. The hydraulic hoses must be exchanges after 6 years at the latest.
16. Before any maintenance or repair work will be carried at the hydraulic
hoses/system, switch off the motor of the tractor and make sure that the
hydraulic system and hoses are pressure free. That can be effected by
actuating the valve lever at the hydraulic of the tractor.
17. After realization of maintenance works, the protective devices must be
installed properly again, otherwise it will result into immediate expiration of
any guarantee claim. Firmly installed, DIN-1553