24-DVRS25N 7
RATING PLATE
NG / NATURAL
LP / PROPANE
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149,1. Electrical connections and grounding must be in accordance
with local codes, if any; if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the US. This appliance is
certified for installation in a bedroom or a bed sitting room. This appliance is only for use with the gas indicated on the rating plate and
may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner‟s manual for details. This appliance is not convertible with other gases, unless a certified kit is used.
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
Il faut que cet appareil soit installé selon les codes locaux, s‟il y en a; sinon, suivre le CAN/CGA-B149 actuel au Canada et ANSI
Z223.1 aux É.-U. Il faut que le raccordement électrique et la mise à la masse soient en conformité avec les codes locaux, s‟il y en a;
sinon, suivre le CAN/CSA C22.1 actuel au Canada et ANSI/NFPA 70 aux É.-U. Cet appareil est certifié pour l‟installation dans une
chambre à coucher ou une pièce qui sert de chambre.
LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLI- ANCES FOR USE
AT HIGH ALTITUDES. RADIATEUR VENTILE, CIRCULATEUR DU TYPE VENTILATEUR.
Tested to / Testée selon les normes : ANSI Z21.88-2009 / CSA 2.33-2009 and CAN/CGA-2.17-M91 VENTED
GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL. This vented gas fireplace heater is not
for use with air filters. Certified for use in both CANADA and USA. / Certifié pour utilisation dans le Canada et
les ÉTATS-UNIS
DO NOT REMOVE THIS LABEL
NE PAS ENLEVER CETTE ÉTIQUETTE
# de série
Serial # LC
Made in Canada by / Fabrique au Canada par:
Archgard Industries Ltd. Mission, B.C.
303-6024 August 2011 WDL
NG LPG
Input rating / Entrée assignée 14,000 - 25,000 BTU/hr
( 4.10 - 7.33 kW)
14,000 - 25,000 BTU/hr
(4.10 - 7.33 kW)
Manifold pressure / Pression d’admission 3.5” W.C. (0.9 kPa) 10.0” W.C. (2.5 kPa)
Orifice size / Dimension de l’orifice #43 DMS (2.26 mm dia.) #54 DMS (1.397 mm dia.)
Minimum supply pressure for purpose of
input adjustment / Pression minimale d’ali-
mentation pour le but d'ajustement de contri-
bution
5.0” W.C. (1.2 kPa) 11.0” W.C. (2.8 kPa)
Control valve / La soupape contrôle: AMERICAN FLAME AF4044 AMERICAN FLAME AF4044
Altitude / Elevation 0 - 4500 ft (0 - 1372 m) 0 - 4500 ft (0 - 1372 m)
Electrical rating / Tension électrique 120 VAC, 60 Hz 1.4 A 120 VAC, 0.6A
Keep burner and control compartment clean.
See Instructions accompanying the heater.
Maintenir propres le brûleur et le comparti-
ment de commande. Voir les instructions
relatives à l’installation et au fonctionnement
qui accompagnent le radiateur.
Optional fuel conversion kit : 24-CKLP
Minimum clearances to Combustibles / Distances:
Minimales entre l’appareil et les combustibles:
Ceiling / Plafond: 12” (305 mm)
Floor / Plancher: 4” (102 mm)
Adjacent Side Wall/Paroi latéraleadjacent: 4” (102 mm)
See Owners Manual for additional clearances
Sheet