Cat. No. RM3
120V AV
Relay Module
DESCRIPTION:
This accessory relay is designed to be used to activate auxiliary devices
such as bells, lights, door closers, etc., when used with 120VAC powered
smoke and carbon monoxide alarms. The relay contacts will activate
whenever the detector sounds an alarm and will automatically deactivate
when the detector stops alarming.
SPECIFICATION
Relay Contact
Contact Ratings: (Maximum)
MANUFACTURED BY: DISTRIBUTED BY: FOR TECHNICAL HELP OR REPRESENTATIVE NEAREST YOU
PHONE 1-800-392-1395
8AM-5PM (CENTRAL TIME)
CM2155
BRK®Electronics
3901 Liberty Street Road
Aurora, IL 6050 -8122
©1998 BRK Brands, Inc.
Made in USA
MAX. OF 12 INTERCONNECTED
VOLTAGE RESISTIVE MOTOR
120 VAC 15 AMP 1/3 H.P.
30 VDC 15 AMP
INSTALLATION
To install this relay to a BRK AC smoke or carbon monoxide alarm,
connect the power wires as listed below. (If wiring the relay remote from
the detector, use a maximum of 1000 feet of #18AWG or larger wire
rated at least 300V.):
Alarm Relay
BLACK WIRE (HOT) BLACK WIRE
WHITE WIRE (NEUTRAL) WHITE WIRE
ORANGE WIRE (INTERCONNECT) GRAY WIRE
IMPORTANT: Orange wire from detector must be connected to gray
wire from relay.
Now connect the accessory to be activate by the relay to the relay’s
switch contact wires as listed below.
(Use wiring appropriate to the auxiliary device being controlled):
BROWN WIRE: COMMON CONTACT
ORANGE WIRE : NORMALLY CLOSED CONTACT
BLUE WIRE: NORMALLY OPEN CONTACT
After connection, place the relay inside a junction box, either where the
detector is installed or at a remote location with a proper box cover.