manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Woodward
  6. •
  7. Relay
  8. •
  9. Woodward BU1-DC2 User manual

Woodward BU1-DC2 User manual

Other Woodward Relay manuals

Woodward MFR 15 User manual

Woodward

Woodward MFR 15 User manual

Woodward MRIK3 User manual

Woodward

Woodward MRIK3 User manual

Woodward XR1 User manual

Woodward

Woodward XR1 User manual

Woodward MRP2 User manual

Woodward

Woodward MRP2 User manual

Woodward WIC1 Series User manual

Woodward

Woodward WIC1 Series User manual

Woodward MFR 11 User manual

Woodward

Woodward MFR 11 User manual

Woodward WIP1 User manual

Woodward

Woodward WIP1 User manual

Woodward MFR 12 User manual

Woodward

Woodward MFR 12 User manual

Woodward WIC1 Series User manual

Woodward

Woodward WIC1 Series User manual

Woodward MFR 300 K55 User manual

Woodward

Woodward MFR 300 K55 User manual

Woodward MR Series User manual

Woodward

Woodward MR Series User manual

Woodward XRI1-IR User manual

Woodward

Woodward XRI1-IR User manual

Woodward High PROTEC MRU4 User manual

Woodward

Woodward High PROTEC MRU4 User manual

Woodward WIP1 User manual

Woodward

Woodward WIP1 User manual

Woodward MRI3-ITE User manual

Woodward

Woodward MRI3-ITE User manual

Woodward IKD Series User manual

Woodward

Woodward IKD Series User manual

Woodward MFD 11 Packages User manual

Woodward

Woodward MFD 11 Packages User manual

Woodward MRN3 Series User manual

Woodward

Woodward MRN3 Series User manual

Woodward HighPROTEC MRU4 User manual

Woodward

Woodward HighPROTEC MRU4 User manual

Woodward PROFESSIONAL Series User manual

Woodward

Woodward PROFESSIONAL Series User manual

Woodward MRG3 User manual

Woodward

Woodward MRG3 User manual

Woodward MFR 13 Series User manual

Woodward

Woodward MFR 13 Series User manual

Woodward MRI3 User manual

Woodward

Woodward MRI3 User manual

Woodward MRR1 User manual

Woodward

Woodward MRR1 User manual

Popular Relay manuals by other brands

ABB SSR32 product manual

ABB

ABB SSR32 product manual

Siemens SIRIUS 3UG4633 operating instructions

Siemens

Siemens SIRIUS 3UG4633 operating instructions

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Siemens

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Eaton easyE4 series Application note

Eaton

Eaton easyE4 series Application note

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

Leuze MSI-SR5B Original operating instructions

Leuze

Leuze MSI-SR5B Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BU1-DC2 – DC Voltage Relay
Manual BU1-DC2 (Revision A)
Woodward Manual BU1-DC2 GB
2 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
provided by Woodward Governor Company is believed to be correct and reliable. However, no responsibility is as-
sumed by Woodward Governor Company unless otherwise expressly undertaken.
© Woodward 1994-2008
DOK-TD-BU1-DC2E Rev.A
Woodward Manual BU1-DC2 GB
Application
Supervision of DC voltages
Function
Unit BU1-DC2 is equipped with an over- (U>) and undervoltage supervision (U<) with separate ad-
justable pick-up values and common trip delay (t) and hysteresis (DIFF).
The DC voltage measured is constantly compared with the set reference values. Any voltage sig-
nal, which exceeds the set reference value for overvoltage, or falls below the set reference value
for undervoltage, will cause the respective relay to trip after elaps of the time delay.
Pick-up of the supervision circuit, either U> or U<, is displayed by the corresponding flashing LED.
At undervoltage tripping LED U< extinguishes. At U>-tripping LED U> is steady lit.
Technical data
rated voltage Un: 12 V or 24 V
Power consumption: 3 W
dropout to pickup ratio: dependent on the set hysteresis
dropout time: 300 ms
Minimum operating delay: 300 ms
Output relay
max. breaking capacity: ohmic 250 V AC/120 V DC
inductive 500 V AC/ 75 W DC
rated current: 5 A
making current: 20 A
System Data
regulations: VDE 0435 part 303
temperature range at
storage and operation: -25°C to 70°C
Mechanical stress:
shock: class 1 acc. to DIN IEC 255-21-2
vibration: class 1 acc. to DIN IEC 255-21-1
degree of protection
unit front: IP 40 at closed front cover
weight: approx. 0.3 kg
mounting position: any
4 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
DOK-TD-BU1-DC2E Rev.A
Figure 1: Front plate
Unit BU1-DC2 is designed to be fastened onto a DIN-rail acc. to DIN EN 50022, same as all units
of the BASIC LINE.
The front plate of the unit is protected with a sealable transparent cover (IP40).
Please remove the transparent cover at the appropriate openings with a screw driver to adjust the
relay.
LEDs
LED U< is used to indicate trouble free operation with steady light. LEDs U> and U< indicate
pickup of the re-lay by flashing.
At undervoltage tripping LED U< extinguishes.
LED U> indicates tripping at overvoltage (steady light).
Figure 2: Dimensional drawing BU1-DC2
Woodward Manual BU1-DC2 GB
Auxiliary voltage supply
Unit BU1-DC2 needs no separate auxiliary voltage supply. The supply voltage can be formed di-
rectly from the measuring quantity.
Figure 3: Connection diagram
Figure 4: Contact positions
6 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
Connecting terminals
The connection up to a maximum of 2 x 2.5 s mm2cross-section conductors is possible. For this
procedure the transparent cover of the unit has to be removed.
Setting ranges
U<: 0.7 - 1.1 Un
U>: 1.0 - 1.4 Un
t: 0 - 100 s
DIFF: 2 - 10 %
Order form
DC voltage relay BU1DC2
Rated voltage 12 V/DC
24 V/DC 12
24
DOK-TD-BU1-DC2E Rev.A
Woodward Manual BU1-DC2 GB
Woodward Kempen GmbH
Krefelder Weg 47 ⋅D – 47906 Kempen (Germany)
Postfach 10 07 55 (P.O.Box) ⋅D – 47884 Kempen (Germany)
Phone: +49 (0) 21 52 145 1
Internet
www.woodward.com
Sales
Phone: +49 (0) 21 52 145 216 or 342 ⋅Telefax: +49 (0) 21 52 145 354
e-mail: [email protected]
Service
Phone: +49 (0) 21 52 145 614 ⋅Telefax: +49 (0) 21 52 145 455
e-mail: [email protected]
8 DOK-TD-BU1-DC2E Rev.A