manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Woodward
  6. •
  7. Relay
  8. •
  9. Woodward BU1-DC2 User manual

Woodward BU1-DC2 User manual

BU1-DC2 – DC Voltage Relay
Manual BU1-DC2 (Revision A)
Woodward Manual BU1-DC2 GB
2 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
provided by Woodward Governor Company is believed to be correct and reliable. However, no responsibility is as-
sumed by Woodward Governor Company unless otherwise expressly undertaken.
© Woodward 1994-2008
DOK-TD-BU1-DC2E Rev.A
Woodward Manual BU1-DC2 GB
Application
Supervision of DC voltages
Function
Unit BU1-DC2 is equipped with an over- (U>) and undervoltage supervision (U<) with separate ad-
justable pick-up values and common trip delay (t) and hysteresis (DIFF).
The DC voltage measured is constantly compared with the set reference values. Any voltage sig-
nal, which exceeds the set reference value for overvoltage, or falls below the set reference value
for undervoltage, will cause the respective relay to trip after elaps of the time delay.
Pick-up of the supervision circuit, either U> or U<, is displayed by the corresponding flashing LED.
At undervoltage tripping LED U< extinguishes. At U>-tripping LED U> is steady lit.
Technical data
rated voltage Un: 12 V or 24 V
Power consumption: 3 W
dropout to pickup ratio: dependent on the set hysteresis
dropout time: 300 ms
Minimum operating delay: 300 ms
Output relay
max. breaking capacity: ohmic 250 V AC/120 V DC
inductive 500 V AC/ 75 W DC
rated current: 5 A
making current: 20 A
System Data
regulations: VDE 0435 part 303
temperature range at
storage and operation: -25°C to 70°C
Mechanical stress:
shock: class 1 acc. to DIN IEC 255-21-2
vibration: class 1 acc. to DIN IEC 255-21-1
degree of protection
unit front: IP 40 at closed front cover
weight: approx. 0.3 kg
mounting position: any
4 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
DOK-TD-BU1-DC2E Rev.A
Figure 1: Front plate
Unit BU1-DC2 is designed to be fastened onto a DIN-rail acc. to DIN EN 50022, same as all units
of the BASIC LINE.
The front plate of the unit is protected with a sealable transparent cover (IP40).
Please remove the transparent cover at the appropriate openings with a screw driver to adjust the
relay.
LEDs
LED U< is used to indicate trouble free operation with steady light. LEDs U> and U< indicate
pickup of the re-lay by flashing.
At undervoltage tripping LED U< extinguishes.
LED U> indicates tripping at overvoltage (steady light).
Figure 2: Dimensional drawing BU1-DC2
Woodward Manual BU1-DC2 GB
Auxiliary voltage supply
Unit BU1-DC2 needs no separate auxiliary voltage supply. The supply voltage can be formed di-
rectly from the measuring quantity.
Figure 3: Connection diagram
Figure 4: Contact positions
6 DOK-TD-BU1-DC2E Rev.A
Manual BU1-DC2 GB Woodward
Connecting terminals
The connection up to a maximum of 2 x 2.5 s mm2cross-section conductors is possible. For this
procedure the transparent cover of the unit has to be removed.
Setting ranges
U<: 0.7 - 1.1 Un
U>: 1.0 - 1.4 Un
t: 0 - 100 s
DIFF: 2 - 10 %
Order form
DC voltage relay BU1DC2
Rated voltage 12 V/DC
24 V/DC 12
24
DOK-TD-BU1-DC2E Rev.A
Woodward Manual BU1-DC2 GB
Woodward Kempen GmbH
Krefelder Weg 47 ⋅D – 47906 Kempen (Germany)
Postfach 10 07 55 (P.O.Box) ⋅D – 47884 Kempen (Germany)
Phone: +49 (0) 21 52 145 1
Internet
www.woodward.com
Sales
Phone: +49 (0) 21 52 145 216 or 342 ⋅Telefax: +49 (0) 21 52 145 354
e-mail: [email protected]
Service
Phone: +49 (0) 21 52 145 614 ⋅Telefax: +49 (0) 21 52 145 455
e-mail: [email protected]
8 DOK-TD-BU1-DC2E Rev.A

Other Woodward Relay manuals

Woodward XR1 User manual

Woodward

Woodward XR1 User manual

Woodward MFR 12 User manual

Woodward

Woodward MFR 12 User manual

Woodward High PROTEC MRU4 User manual

Woodward

Woodward High PROTEC MRU4 User manual

Woodward MRR1 User manual

Woodward

Woodward MRR1 User manual

Woodward HighProTec Series User manual

Woodward

Woodward HighProTec Series User manual

Woodward ESDR 4T User manual

Woodward

Woodward ESDR 4T User manual

Woodward PROFESSIONAL Series User manual

Woodward

Woodward PROFESSIONAL Series User manual

Woodward MRU3-1 User manual

Woodward

Woodward MRU3-1 User manual

Woodward easYprotec-1000 Series User manual

Woodward

Woodward easYprotec-1000 Series User manual

Woodward MRS1 User manual

Woodward

Woodward MRS1 User manual

Woodward EM80 Technical manual

Woodward

Woodward EM80 Technical manual

Woodward HighPROTEC MRU4 User manual

Woodward

Woodward HighPROTEC MRU4 User manual

Woodward MRN3 Series User manual

Woodward

Woodward MRN3 Series User manual

Woodward WIP1 User manual

Woodward

Woodward WIP1 User manual

Woodward MR Series User manual

Woodward

Woodward MR Series User manual

Woodward MFR 13 Series User manual

Woodward

Woodward MFR 13 Series User manual

Woodward MFR 15 User manual

Woodward

Woodward MFR 15 User manual

Woodward ESDR 4 User manual

Woodward

Woodward ESDR 4 User manual

Woodward highprotec MRI4 User manual

Woodward

Woodward highprotec MRI4 User manual

Woodward MFR 300 K55 User manual

Woodward

Woodward MFR 300 K55 User manual

Woodward IKD Series User manual

Woodward

Woodward IKD Series User manual

Woodward MRI3-ITE User manual

Woodward

Woodward MRI3-ITE User manual

Woodward 2301A User manual

Woodward

Woodward 2301A User manual

Woodward XRI1-ER User manual

Woodward

Woodward XRI1-ER User manual

Popular Relay manuals by other brands

ABB CVX Instruction leaflet

ABB

ABB CVX Instruction leaflet

Pilz PNOZ s50 operating manual

Pilz

Pilz PNOZ s50 operating manual

Arcteq AQ-F201 instruction manual

Arcteq

Arcteq AQ-F201 instruction manual

Siemens 3TX7014 operating instructions

Siemens

Siemens 3TX7014 operating instructions

Seg HighTECH MRR1 manual

Seg

Seg HighTECH MRR1 manual

Autonics ABS Series user guide

Autonics

Autonics ABS Series user guide

Allen-Bradley Guardmaster MINOTAUR MSR121RT installation instructions

Allen-Bradley

Allen-Bradley Guardmaster MINOTAUR MSR121RT installation instructions

ABB CV Series Instruction leaflet

ABB

ABB CV Series Instruction leaflet

Keysight E1460A user manual

Keysight

Keysight E1460A user manual

Areva MiCOM P125 Technical guide

Areva

Areva MiCOM P125 Technical guide

ABB KS Instruction leaflet

ABB

ABB KS Instruction leaflet

ENGO CONTROLS ERM12A quick guide

ENGO CONTROLS

ENGO CONTROLS ERM12A quick guide

WEG PSRW user manual

WEG

WEG PSRW user manual

Beckhoff KM2604 Documentation

Beckhoff

Beckhoff KM2604 Documentation

Niko 10-830 manual

Niko

Niko 10-830 manual

Siemens 7UG0583-1CU20 operating instructions

Siemens

Siemens 7UG0583-1CU20 operating instructions

Siemens SIRIUS 3RA1953-2A Original operating instructions

Siemens

Siemens SIRIUS 3RA1953-2A Original operating instructions

Siemens SIRIUS 3RP2005 Original operating instructions

Siemens

Siemens SIRIUS 3RP2005 Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.