Brocade Communications Systems Slim Rail Rack Mount Operating and maintenance manual

®
53-1002176-03
*53-1002176-03*
53-1002176-03
5 August 2013
Slim Rail Rack Mount Kit
Installation Procedure
Supporting Brocade 6510, 6505

2 of 10 Slim Rail Rack Mount Kit Installation Procedure
Publication Number: 53-1002176-03
Copyright © 2011-2013 Brocade Communications Systems, Inc. All Rights Reserved.
ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are
registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications
Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their
respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment,
equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time,
without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available.
Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may
require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss,
cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other open source
license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open
source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: [email protected]
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: [email protected]
Title Publication number Summary of changes Date
Slim Rail Rack Mount Kit Installation
Procedure
53-1002176-01 New document April 2011
Slim Rail Rack Mount Kit Installation
Procedure
53-1002176-02 Added Brocade 6505 December 2011
Slim Rail Rack Mount Kit Installation
Procedure
53-1002176-03 Corrected rack depth
information.
August 2013

Slim Rail Rack Mount Kit Installation Procedure 3 of 10
Publication Number: 53-1002176-03
Installation requirements
ATTENTION
The rails in the Slim Rail Rack Kit have been specially designed for the Brocade 6510 and 6505. Because the switch
is slightly wider than most switches, the rails are narrower to account for the additional width. Do not attempt to mount
the 6510 or 6505 with standard rail kits.
Allow 15 to 30 minutes to complete this procedure. Note the following requirements to ensure correct installation
and operation:
•Provide space in a EIA rack, as required for the switch type, with a minimum distance of 27 in. (68.58 cm) and a
maximum distance of 31 in. (78.74 cm) between the front and back posts.
•Verify that the additional weight of the switch does not exceed the rack’s weight limits.
•Ensure that an electrical branch circuit with the following characteristics is available:
-Required voltage and frequency as indicated in the hardware reference manual. (200-240 VAC is always
preferred)
-Protection by a circuit breaker in accordance with local electrical codes.
-Supply circuit, line fusing, and wire size that conform to the electrical rating on the switch nameplate.
-Grounded outlet compatible with the power cord and installed by a licensed electrician.
•Ensure that all equipment installed in the rack is grounded through a reliable branch circuit connection. Do not
rely on a secondary connection to a branch circuit, such as a power strip.
•Ensure that the rack is mechanically secured to ensure stability.
•Ensure that the air temperature at the fan inlet is less than 40oCelsius (104oFahrenheit) during switch
operation.
•Ensure that the airflow available at the air vents meets the minimum requirements for the switch.
ATTENTION
Ensure that the switch is oriented properly with the air-intake aisle. The power supply and fan FRU airflow must be the
same to prevent overheating. If both FRUs have the Intake (I) label or no label, orient the switch with the fan facing
the air-intake aisle. If both FRUs have the Exhaust (E) label, orient the port side of the switch to face the air-intake
aisle.
Time Required
Allow 15 to 30 minutes to complete this procedure.
Items Required
The following items are required to install a switch using the slimline fixed rack mount kit:
•Clamps or other means of temporarily supporting the switch in the rack.
•Phillips #2 screwdriver with torque capability.
•1/4 in. slotted-blade screwdriver with torque capability.

4 of 10 Slim Rail Rack Mount Kit Installation Procedure
Publication Number: 53-1002176-03
Parts List
Ensure that the items listed in Table 1 and illustrated in Figure 1 are included in the kit.
TABLE 1 Parts list for mounting kit for 4-post rack
Part number Description Quantity
42-1000662 Bracket, front right 1
42-1000664 Bracket, front left 1
42-1000665 Bracket, rear left 1
42-1000663 Bracket, rear right 1
52-0200050 Screw, 8-32 x 5/16 in., panhead Phillips (torque to 15 in-lb, 17 cm-kg) 10
52-0000241 Screw, 6-32 x 1/4 in., flathead Phillips (torque to 9 in-lb, 10 cm-kg) 8
52-0000211 Screw, 10-32 x 5/8 in., panhead Phillips (torque to 25 in-lb, 29 cm-kg) 8
52-0000210 Retainer nut, 10-32 8
52-0000270 Retainer nut, 10-32, round holes 8

Slim Rail Rack Mount Kit Installation Procedure 5 of 10
Publication Number: 53-1002176-03
FIGURE 1 Items in slimline fixed rack mount kit
1 Bracket, front right 6 Screw, 6-32 x 1/4 in., flathead Phillips
2 Bracket, front left 7 Screw, 10-32 x 5/8 in., panhead Phillips
3 Bracket, rear left 8 Retainer nut, 10-32, (for square-hole rack rails)
4 Bracket, rear right 9 Retainer nut, 10-32, (for round-hole rack rails)
5 Screw, 8-32 x 5/16 in., panhead Phillips
1
2
3
4
56789

6 of 10 Slim Rail Rack Mount Kit Installation Procedure
Publication Number: 53-1002176-03
Installation procedure
ATTENTION
The switch must be turned off and disconnected from the fabric during this procedure.
Complete these tasks to install the switch in a rack:
•“Attaching front brackets”
•“Installing the switch in the rack”
•“Attaching rear brackets to front brackets”
•“Attaching rear brackets to rack rails”
Attaching front brackets
Complete the following steps to attach the front brackets to the switch.
1. Position the right front bracket with the flat side against the right side of the switch (Figure 2).
2. Insert two 8-32 x 5/16 in. screws into one of the pairs of vertically aligned holes in the bracket and then into the
pair of holes on the side of the switch. There are three pairs of vertically aligned holes in the brackets. To install
the switch flush to the front of the rack, use the pair of holes at the front of the bracket. To install the switch in a
recessed position in the rack, use one of the other two pairs of bracket holes that are set back from the end of
the bracket.
3. Insert each 8-32 x 5/16 in. screw through the holes in the bracket and into the corresponding hole in the switch
and tighten all 8-32 x 5/16 in. screws to a torque of 15 in-lb (17 cm-kg).
4. Repeat step 1 through step 3 to attach the left front bracket to the left side of the switch.
FIGURE 2 Position the front bracket (6510 shown, 6505 similar)
1 Bracket, front right 3 Screw, 8-32 x 5/16 in., panhead Phillips (5 per side)
2 Bracket, front left
31
2

Slim Rail Rack Mount Kit Installation Procedure 7 of 10
Publication Number: 53-1002176-03
Installing the switch in the rack
Complete the following steps to install the switch in the rack.
1. Position the switch in the rack (Figure 3), providing temporary support under the switch until the rail kit is
secured to the rack.
2. Attach the right front bracket to the right front rack post using two 10-32 x 5/8 in. screws and two retainer nuts.
3. Repeat step 2 to attach the left front bracket to the left front rack post and tighten all 10-32 x 5/8 in. screws to
a torque of 25 in-lb (29 cm-kg).
FIGURE 3 Position the switch in the rack (6510 shown, 6505 similar)
Attaching rear brackets to front brackets
Complete the following steps to attach the rear brackets to the front brackets.
1. Position the right rear bracket inside the right front bracket (Figure 4).
2. Attach the brackets using four 6-32 x 1/4 in. screws.
3. Adjust the brackets to rack depth and tighten the screws to a torque of 9 in-lb (10 cm-kg).
1 Bracket, front right 3 Screw, 10-32 x 5/8 in., panhead Phillips
2 Bracket, front left 4 Retainer nut, 10-32, square or round hole as needed
4
2
3
1

8 of 10 Slim Rail Rack Mount Kit Installation Procedure
Publication Number: 53-1002176-03
4. Repeat step 1 through step 3 to attach the left rear bracket to the left front bracket.
FIGURE 4 Position the rear and front brackets (6510 shown, 6505 similar)
Attaching rear brackets to rack rails
Complete the following steps to attach the rear brackets to the rack rails.
1. Attach the right rear bracket to the right rear rack rail using two 10-32 x 5/8 in. screws and two retainer nuts
(Figure 5).
2. Repeat step 1 to attach the left rear bracket to the left rear rack rail and tighten all the 10-32 x 5/8 in. screws to
a torque of 25 in-lb (29 cm-kg).
3. Provide power to the switch by connecting the power cords to the power connectors on the switch and a power
outlet. Some switches require you to flip a power switch to be powered on.
ATTENTION
Connect the power cords to a grounded outlet only. Ensure that any power cord is routed so that it is not exposed
to stress. Leave a minimum service loop of 6 in. in the power cords at the connection to switch. This allows
enough freedom of movement to plug and unplug the power cords.
NOTE
If your power cord management scheme involves supporting the power cord on the rack rail, Brocade
recommends that you purchase adhesive-backed cable retainers and fasten these to the rails to hold the cords.
NOTE
Do not connect the switch to the network until the IP address is correctly set. Refer to the appropriate hardware
reference manual for information on setting the IP address for the switch.
1 Bracket, front right 3 Bracket, rear left
2 Bracket, rear right 4 Screw, 6-32 x 1/4 in., flathead Phillips (four per bracket)
2
1
34

Slim Rail Rack Mount Kit Installation Procedure 9 of 10
Publication Number: 53-1002176-03
FIGURE 5 Attach the rear bracket to the rack post (6510 shown, 6505 similar)
1 Bracket, front right 3 Retainer nut, 10-32, square or round holes as needed
2 Bracket, rear right 4 Screw, 10-32 x 5/8 in., panhead Phillips
3
2
1
4

10 of 10 Slim Rail Rack Mount Kit Installation Procedure
Publication Number: 53-1002176-03
Table of contents
Other Brocade Communications Systems Rack & Stand manuals
Popular Rack & Stand manuals by other brands

OPEN SPACES
OPEN SPACES Entryway Rack Assembly instructions

CyberPower
CyberPower PR750ELCDRT1U user manual

Fibre Glast
Fibre Glast 2214-A quick start guide

Enclume
Enclume Square Pot Rack Assembly instructions

Wali
Wali MF001 installation manual

Workrite
Workrite CONF-1HDA-WOB-S Assembly/installation instructions

Aigis Mechtronics
Aigis Mechtronics Linear MT-MWB Series Installation and operating instructions

BEKA
BEKA SG-FS Assembly instructions

GCX
GCX KP-0003-28 installation guide

Middle Atlantic
Middle Atlantic WoodKit C3 Series instruction sheet

AbleNet
AbleNet AB100USMSFK quick start guide

PEERLESS
PEERLESS DS415 Installation and assembly