Installation
Installation of this fireplace must be according to local codes and regulations in your country. All local regulations,
including those which refer to national and European standards, must be observed when installing this
product.
A metal nameplate is fixed to the product containing information about identification and documentation for the product.
Technical data
Lilla Byskeugnen
DoP: BU_SE_2018_00
Freestanding room heater fired by solid fuel
Minimum distance to combustible materials:
ear: 500 mm – Side: 500 mm
Operation type: Intermittent
Nominal heat output: 12,3 kW
CO: 0,0974% @13%O
2.
Efficiency: 81%
Construction conforms to EN 132 0
The appliance can be operated in a shared flue (if the chimney draft is as recommended)
Follow the assembly- and instructions manual!
Use only recommended fuels!
Additional technical data
Weight: 230 kg
Material: Cast iron
Fuel: Wood
Fire wood length: < 35 cm
Flue outlet: Top, rear
ecommended chimney draft (at nominal heat output): 12 Pa +
Flue gas temperature (at nominal heat output): 187
o
C
Flue pipe dimension: Ø150 mm inside
Floor
Byskeugnen must be placed on a noncombustible floor.
Only place the stove on floors with sufficient carrying capacity, weight of the chimney included. If not, a load distribution
plate can be used.
Floor plates must be in accordance with national laws and regulations.
Contact your local building authorities regarding restrictions and installation requirements in your country.
Distance to walls
Closest distance to combustible walls is 500 mm.
The distance can be reduced by placing a firewall on the walls. Follow the firewall manufacturers recommendations how
much the distance to combustible walls can be reduced.
Air supply
Supply air for the combustion is taken from the room, please ensure that there is adequate air supply from the outdoors to
the room where stove is to be installed. If not, an inlet air vent should be installed on the wall near to the stove.
An inadequate air supply could cause bad combustion and also cause flue gases to escape into the room. This is
dangerous! Symptoms of this include smoky smell, drowsiness, nausea and feeling ill.
Ensure that air vents in the room where the fireplace is located are not blocked. Also, be aware that mechanical fans, such
as kitchen fans, can create a negative pressure that causes poor combustion and, at worst, cause flue gases to escape in to
the room.
The amount of air required for combustion is about 40 m
3
/h
2
Use
Before using the fireplace
Ensure that the installation complies with local codes and regulations in your country. All local regulations, including
those which refer to national and European standards, must be observed when using this product.
Before the use of your Byskeugnen stove, the installation must be inspected by a qualified inspector.
Any modifications to the stove may result in the product and safety features do not function as intended.
This may also be the case if parts that are essential to the functioning and the safety of the product have been
disassembled or removed.
In all these cases, the manufacturer is not responsible for the product and the warranty will become void.
Prevention of personal injury
-During fire the stove gets very hot and can cause burns.
- Never leave young children unattended.
- Use the cold hand device to open the door and to adjust the controls.
Prevention against fire
- Ensure that furniture and other flammable materials do not get too close to the fireplace.
- Never put the fire out with water.
- Only remove the ashes when the fireplace is cold.
- Ash must be disposed outdoors, or where there is no fire hazard
Fuel
Lilla Byskeugnen is a wood stove with a nominal heat output of 12,3 kW.
It is important for proper fuel consumption that the firewood are in the correct size (see list and pictures below) and of
good quality. Good quality wood means dried so the water content is maximum 20%.
Never use painted or impregnated wood or Chipboard or laminated boards, no litter, waste or fuels like petrol,
alcohol or other combustible liquids
Firewood:
Length: < 35 cm
Diameter: Approx. 8 cm
Weight: Between 0,7-1,2 kg per log
Intervals for adding wood: Approx. 50 minutes
Size of the load: 2,5 kg
Amount per load: 2-3 logs.
Medium-sized firewood
Length: 20 - 35cm
Diameter: 3 - 5 cm
Use during lighting
Kindling
Length: 20 - 35cm
Diameter: 1-3 cm
Use during lighting
3
First use
When the stove is used for the first time some smell from the paint can
occur. The room should be thoroughly ventilated during this first use.
Daily use - wood burning
Start up
1 Open the bypass damper. (to improve the draft from the beginning)
2 Open the control for primary air, the control for secondary air and the
two controls for startup air on the door.
3 Place two medium sized firewood in the bottom of the fireplace.
Crumble a newspaper or bark between them and add some kindling
in a criss - cross pattern on top. Finally place a medium-sized fire-
wood on top. In total about 1,5 kg of wood.
4 Before you light up the fire, check the draft in the fireplace. If draft
is weak, open a window during the first minutes of fire.
5 Light the fire and leave the stove door open about 1-2 cm by leaving
it on the handle for some minutes until the firewood is burning.
6 Now close the door
7 When half of the firewood has burnt down, add more medium-sized
firewood to the fire. About 1,5 kg. Add the medium-sized firewood
horizontal and in a criss - cross pattern.
8 Leave the door open 1-2 cm for a minute, thereafter you can close
the door.
9 Now you can close the bypass damper.
Adding firewood
1 Each load should burn down to embers before new firewood is added.
2 Open the bypass damper
3 Open the door slightly and allow the underpressure to level.
4 Add firewood, 2 to 3 logs horizontal. See picture below.
5 Close the door
6 Close the bypass damper
7 Close the two controls for startup air on the door, and after some
minutes adjust the controls for primary and secondary air until you
can see flames from the holes in the back wall
Nominal heat output
For nominal heat output, add three logs, each logs weight between 0,7- 1,0 kg, totally 2,5 kg of firewood. Place the two
largest in the bottom and the smallest on top as shown on the picture above. After one minute close the two controls for
start up air on the door. After two minutes close the control for secondary and leave the control for primary air fully open.
Higher heat outputs
When adding more than three logs or many smaller logs, more air is needed. Then you need to open the controls for start-
up air to get enough air to the combustion.
Ending the fire
When fire is completed and no embers is left in the stove you can close the controls for primary air and the three controls
for startup air on the door to get a long and pleasant after heat.
4
Bypass damper
Open
Closed
Control for secondary air
open closed
Controls for startup air
in (open) - out (closed)
Control for primary air
open closed
Soot door
For sweeping of the channels
and removing of soot and ash.
IMPORTANT
Your stove can be very hot. Use the cold hand device to open the door and to adjust the controls.
When you open the door during fire, always open the bypass damper first to avoid smoke coming in to the room.
Never throw the logs in to the fireplace, the ceramics can crack.
Never fill firewood above the second ceramic stone in the back wall of the combustion chamber. (About half the door)
Always use dry firewood. Water content maximum 20%.
Do not burn litter or waste or other not recommended fuels like petrol, alcohol or other combustible liquids
Use a shovel or similar to remove the ashes from the fireplace.
When handling ash, think about the risk of fire. A metal tin with lid is recommended.
Sweeping of the stove
1 Top decoration and the cooking plate
is removed and the upper portion
cleared of soot and ash.
2 Side ducts (5 x 40 cm) cleaned with
a soft whisper on left side and through
the upper soot door on the right side.
3 Empty the bottom part from soot and
ash through the soot door with a
suitable brush
4 Close the soot doors (remember the
upper soot door) and put back the
cooking plate and top decoration.
Cleaning the glass
Moisten a paper towel with water and dip it in some ash from the stove. ub it over the glass and then clean the glass with
a paper towel with clean water.
Chimney Fire
If a chimney fire occurs or is suspected, the door and all the controls on the door must be closed. If necessary contact the
fire brigade to extinguish it. Always contact a chimney sweep after a chimney fire.
5
Soot door
For sweeping of the channels
and removing of soot and ash.
Upper soot door
For sweeping of the channels
and removing of soot and ash.
Troubleshooting
Poor draft
- If you have a damper mounted in the flue pipe or in the brick chimney, make sure it is open.
- If you have an inlet air vent in to the room, make sure it is open.
- Foggy and rainy weather can have a big impact on the chimney draft and it might be necessary to use other air control
settings to ensure good performance.
- Close or reduce mechanical ventilation such as kitchen fan and open a window during the first minutes of fire.
- Make sure that nothing in the chimney restricts the smoke to escape, soot for instance.
- If you believe you have excessive poor draft in the chimney, seek professional help for measurement and adjustment.
Poor draft after newinstallation
- If you have a damper mounted in the flue pipe or in the brick chimney, make sure it is open.
- If you have an inlet air vent in to the room, make sure it is open. If you dont have an inlet air vent, read about air supply
on page 1.
- Make sure that nothing in the chimney restricts the smoke to escape.
- Make sure that the minimum cross section area of the chimney is according to the installation manual.
- Check the length of the chimney and that it complies with national laws and regulations.
- If you believe you have excessive poor draft in the chimney, seek professional help for measurement and adjustment.
It is difficult to light the fire and the fire dies after a short time
- Make sure that the firewood is dry.
- Check that the air controls on the door is open, see start up procedure on page 4.
- Find out whether the draft is poor. ead about poor draft above.
Unusual amount of soot accumulates on the glass
Some soot will always stick to the glass, and this is added on with each lighting.
Unusual amount of soot on the glass is caused by:
- Poor combustion
- Incorrectly set air controls
- Moisture in the fuel
- Bad draft conditions
Always make the start up fire according to the instructions. emember to open the by bypass damper during start up, and
use kindlings during start up
Most of the soot will burn off when the combustion is good.
See ”Cleaning of the glass” above.
Smoke odour from the stove
Smoke smell occur at times. emember to always open the bypass damper before the door is opened. In some weather
conditions the chimney drafts can be poor. Then be extra careful when you open the door.
Another reason could be that the door was opened when there was a lot of flames.
6

Popular Indoor Fireplace manuals by other brands

Morsø 7840 Instructions for installation and use

Morsø

Morsø 7840 Instructions for installation and use

Napoleon CLEARion Series Installation and operation manual

Napoleon

Napoleon CLEARion Series Installation and operation manual

GlammFire Crea7ion Fire Line E. Series manual

GlammFire

GlammFire Crea7ion Fire Line E. Series manual

Desa CWC42C installation instructions

Desa

Desa CWC42C installation instructions

Wonderfire BR00290 SONNET Installer's guide

Wonderfire

Wonderfire BR00290 SONNET Installer's guide

Valor Portrait Cast Arch Fronts 539 Series installation manual

Valor

Valor Portrait Cast Arch Fronts 539 Series installation manual

Illusion MATRIX GFX-L Owner's instructions & installation manual

Illusion

Illusion MATRIX GFX-L Owner's instructions & installation manual

Quadra-Fire EXCURSION-I owner's manual

Quadra-Fire

Quadra-Fire EXCURSION-I owner's manual

Qlima FFB 8060 user manual

Qlima

Qlima FFB 8060 user manual

SCAN 45i Installation and operation instructions

SCAN

SCAN 45i Installation and operation instructions

Modernhomes 67500 Mahogany Effect Installation and user instruction guide

Modernhomes

Modernhomes 67500 Mahogany Effect Installation and user instruction guide

Amantii 30-TRV-SLIM Assembly, installation and operation instructions

Amantii

Amantii 30-TRV-SLIM Assembly, installation and operation instructions

Dimplex 30" FIREPLACE owner's manual

Dimplex

Dimplex 30" FIREPLACE owner's manual

Mendota ML47-PF2 Installation and operation manual

Mendota

Mendota ML47-PF2 Installation and operation manual

Superior Fireplaces WRT4536RS Installation and operation instructions

Superior Fireplaces

Superior Fireplaces WRT4536RS Installation and operation instructions

Twin-Star International Duraflame DFI021ARU manual

Twin-Star International

Twin-Star International Duraflame DFI021ARU manual

Burley 227 operating instructions

Burley

Burley 227 operating instructions

Tulikivi KTU 1010 operating manual

Tulikivi

Tulikivi KTU 1010 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.