Cadac J-Type Instruction Manual

Audio Mixing Console
-056#..#6+10#n#95'4#1#07#.
.g8;2'

CADAC Electronics plc
One New Street
Luton
Bedfordshire
LU1 5DX
England
Tel +44 (0) 1582 404 202
Fax +44 (0) 1582 412 799
email: info@cadac-sound.com
While every effort has been taken to ensure the accuracy of the contents in this manual, CADAC Audio Mixing Consoles are subject to
continuous development, hence theinformation in this manual may not reflect the latest product updates.
© Copyright CADAC Electronics plc. 2005.

Table of contents iii
Revision J2005-2 J-Type
7DEOH#RI#FRQWHQWV
6(&7,21 3$*(
*HQHUDO#3UHFDXWLRQV 11111111111111111111111111111111111111111111111111111#Y
,QWURGXFWLRQ 1111111111111111111111111111111111111111111111111111111111111111#YLL
4&RQQHFWLQJ#WKH#PL[HU#V\VWHPV 11111111111111111111111111111111 #404
1.1 Console modularity ....................................................................... 1-1
1.2 Frame rear connections................................................................1-1
1.3 Connect Power supply systems....................................................1-2
1.4 Connecting the console frames .................................................. 1-11
1.5 Connect Console Automation System ........................................ 1-14
1.6 Connect main frame facilities from modules to frame................. 1-19
1.7 Switching ON .............................................................................. 1-20
5-07\SH#&&0111111111111111111111111111111111111111111111111111111111111111 #504
2.1 CCM Front Panel switches and displays ......................................2-1
2.2 CCM rear panel connectors.......................................................... 2-4
2.3 Internal module settings................................................................2-7
2.4 Fader interface module (7303)...................................................... 2-8
2.5 Module level software ...................................................................2-9
2.6 The System Setup menu ............................................................ 2-11
63URJUDPPDEOH#PRGXOHV#0#LQSXW 11111111111111111111111111111111 #604
3.1 7865 Stereo Input Channel........................................................... 3-1
3.2 7496 Dual Input Channel ............................................................ 3-11
3.3 7830 Dual input channel............................................................. 3-23
73URJUDPPDEOH#0RGXOHV#0#6XE/#0DWUL[/#350#)#$X[11 #704
4.1 7925 Programmable Group Module..............................................4-1
4.2 7972 Programmable Aux Groups Module................................... 4-11
4.3 7548 Programmable Routing - Slave Mod. Mk II........................4-17
81RQ0SURJUDPPDEOH#PRGXOHV#0#LQ#DQG#RXW 11111111111111111 #804
5.1 8059 Dual Input Channel .............................................................. 5-1
5.2 6907 Input Channel.......................................................................5-9
5.3 6908 Sub and Matrix module......................................................5-17
91RQ0SURJUDPPDEOH#PRGXOHV#0###################################################
#$X[#*URXS/#6WHUHR#UHWXUQ#)#4XDG#3DQQLQJ 11111111111111 #904
6.1 6909 Auxiliary Group module........................................................6-1
6.2 6912 Stereo return module ........................................................... 6-4
6.3 7106 Quad Panning module .........................................................6-7
:1RQ0SURJUDPPDEOH#PRGXOHV#0#DQFLOODULHV 1111111111111111 #:04
7.1 6910 Oscillator, PFL & Stereo Aux module ..................................7-1
7.2 7974 Oscillator, Comms & PFL module........................................ 7-9
7.3 6913 Communications module ................................................... 7-17
7.4 6978 Communications module ................................................... 7-23
;-07\SH#IDGHUV 111111111111111111111111111111111111111111111111111111111111 #;04
8.1 7934 Stereo VCA Fader................................................................8-2
8.2 7935 Stereo Input Motor fader...................................................... 8-4
8.3 7936 VCA Channel fader.............................................................. 8-7
8.4 7937 Channel Motor fader ............................................................8-9
8.5 7955 DC Master fader................................................................. 8-12
8.6 7956 DC Master Motor fader ...................................................... 8-14
$SSHQGLFHV 111111111111111111111111111111111111111111111111111111111111#$330,
,QGH[ 11111111111111111111111111111111111111111111111111111111111111111 #,1'(;04

iv Table of contents
J-Type Revision J2005-2

General Precautions v
J-Type Revision J2005-2
*HQHUDO#3UHFDXWLRQV
'DPDJH
Do not place heavy objects on the control surface, expose it to sharp objects or han-
dle the console in any way that may cause damage e.g. rough handling and/or
excessive vibration.
(QYLURQPHQW
Do not subject theequipment to dirt, dust, heat or vibration during operation or stor-
age. Never expose the console to rain or moisture in any form. Should the console
become wet, turn it off and disconnect from mains without further delay. The console
should be given sufficient time to dry out, before recommencing operation.
&OHDQLQJ
When cleaning the console, never use chemicals, abrasive substances or solvents.
The console control panels should be cleaned using a soft brush and a dry lint-free
cloth. For persistent marks, use a soft cloth and isopropyl alcohol. Switches and
potentiometers do NOT require cleaning or lubrication. For faders, see below.
7UDQVSRUW
Transport the console in its purpose built flight-case; whilst at the same time taking
precautions to protect the control surface from any damage. Always make sure ade-
quate manpower is available and correct lifting methods are taken when moving the
console.
6DIHW\#,QVWUXFWLRQV
Read the following before using the equipment:
,QVWUXFWLRQV
Keep these instructions for future reference. Follow all warnings in this manual and
those printed on the power supply units.
,QVWDOODWLRQ
The console must be installed following the guide lines in this manual. Never connect
power amplifier outputs directly to the console. Connectors and plugs must never be
used for any other purpose than for what they are intended.
&RYHUV
Never use the power supply units without covers fitted. All service work must be car-
ried out by qualified personnel only.
3RZHU
The power supply units mustalways be connected to correctly rated mains power as
referred to in this manual and marked on the power supply units. The power supply
units must, at all times, be connected to the local mains power supply using the sup-
plied powercord. In cases where the supplied plug does notfit, a qualified electrician
must be consulted.
3RZHU#FRUG
The power cord must be routed in such a way that the risks of accidentally stepping
on it, stretching it or it being pinched, are minimized.
:DUQLQJ
THIS EQUIPMENT MUST BE EARTHED !
0RLVWXUH
In order to minimize risks of fire hazards and/or electric shock, the power supply unit
must never be exposed to moisture or water in any form; orbe used in a damp orwet
environment. Neverplace liquid containers, such as for instance coffee/tea mugs, on
the power supply unit, so as to avoid spillage into openings.
9HQWLODWLRQ
Ventilation slots on the power supply or the console must never be covered or in any
other way obstructed. Air flow required for safe operation may otherwise be
restricted. Where the console is to be operated in its flight-case, then this must be
located in such a way that it allows for proper ventilation.
6HUYLFH
Refer servicing to qualifiedtechnical personnel only.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN

vi General Precautions
Revision J2005-2 J-Type

Introduction vii
Revision J2005-2 J-Type
,QWURGXFWLRQ
The CADAC marque has an unequalled reputation for audio performance, reliability
and engineering excellence - qualities reflected in a product range which encom-
passes the full spectrum of live sound applications - from rock’n’roll to theatre, from
musicals to opera. Focusing solely on the demanding live sound sector, CADAC con-
soles deliver quality without compromise.
The CADAC J-Type has gained benchmark status as the world’s leading console for
major musical productions, based on its combination of exceptional audio quality,
reliability and flexibility. The industry standard in London’s West End and on Broad-
way, the J-Type credit list includes the world’s most successful and longest running
musicals - Miss Saigon, Les Miserables, Disney’s Lion King, Beauty & The Beast,
Phantom of the Opera and Sunset Boulevard, to name a few.
Resisting the pressures of cost-engineering and high-speed production. CADAC
consoles aredesigned and builtto the highest standards, ensuring that“the quality is
remains long after the cost is forgotten”. A CADAC console is sound investment, cre-
ated to give flawless performances, night after night, and year after year.
Being the first console to feature CADAC’s unique frame design, the CADAC J-Type
allows users to put any module in any position, thus allowing for fast configuration of
the console to suit the project in hand. Internal audio bussing is balanced and uses
ribbon cables with “floating” connectors fitted on steel cradles. Data busses use ded-
icated ribbon cable. All power bussing is rated at 40A per rail. Frame-mounted input
connectors include diode-mixed power inlets, earth points, headphone and Littlite
connectors. The frames incorporate multiplecooling fans with a 5-speed control.Any
frame size may be specified 25 to 63 modules wide.
The CADAC J-Type has an impressive range of input modules to choose from,
underlining its performance capabilities - original mono inputs can be combined with
programmable dualinput and stereo channels to achieve the precise routing and mix
required for every cue. This is complemented by the J-Type’s versatile matrix - with
up to 16 sub and 32 matrix group outputs.
The J-Type programmable modules offers extensive automation facilities. Designed
for use alongside existing J-Type modules, all pot and switch settings for each cue
can be stored and recalled during a performance - including those of the routing, EQ
and insert points.
This manual provides the user with information on the installation of the J-Type con-
sole together with a concise console operating guide and functional descriptions of
all the available modules and faders. Usedin conjunction with the sophisticated con-
sole cue automation system - the Sound Automation Manager (SAM), running on a
Windows ® operating system - has produced a sound mixing and control system that
provides a complete sound control system that is easy to programme whilst provid-
ing the traditional CADAC sound and performance quality.

viii Introduction
J-Type Revision J2005-2

Connecting the mixer systems 1-1
Revision J2005-2 J-Type
4&RQQHFWLQJ#WKH#PL[HU#V\VWHPV
414 &RQVROH#PRGXODULW\
The J-Type was the first console to feature CADAC’s unique frame design which
allow users to put any module in any position, thus configuring the console to suit the
project in hand. Each module is fitted with XLR connectors and jack sockets on the
rear vertical face, enabling the module to be moved quickly and easily.
The J-Type module’s design features a motherboard, with plug-in daughter boards
for all audio and digital control functions. This ensures servicing simplicity and fast
replacement of any faulty component. Each module may be plugged into any posi-
tion in the console frame, by means of top quality two-part connector system, which
isdesigned as a mating pair to provide excellent mechanical and electrical reliability.
A rail system is used to guide each module into its correctposition. Also, the console
design allows modules to be removed or inserted without powering down.
415 )UDPH#UHDU#FRQQHFWLRQV
The connections on the J-Type console rear frame include the following (from left to
right):
■
■■
■Audio Bus - frame to frame, up to 4 frames can be connected.
■
■■
■PFL output to next frame.
■
■■
■PFL input from module.
■
■■
■Frame, GND and 0V-connections with grounding bar.
■
■■
■PSU1 connector
■
■■
■PSU2 connector
■
■■
■Output for monitoring of PSUs
■
■■
■Data Busses + Frame address selector
■
■■
■Littlite input from PFL module.
■
■■
■Littlite output to next frame.
■
■■
■Littlite output to lights
■
■■
■COMMS output
■
■■
■Fader Bus
The use of these connectors is described in 1.3.5 Main and extension frame power
connections, 1.4 Connecting the console frames and 1.5 Connect Console Automa-
tion System.
4
56
7
4
5
6
7
$
%
$
%
Audio Bus - frame to
frame
From COMMS module
To next frame
Frame-GND-0
PSU 1 & PSU2
PSU Monitor
Data Bus
Selector - Frame Address
Console Littlites
To Lights
To Next frame
From COMMS module
COMMS
Fader Bus
FIG 1-1. Frame Rear Connections

1-2 Connecting the mixer systems
J-Type Revision J2005-2
416 &RQQHFW#3RZHU#VXSSO\#V\VWHPV
41614 3RZHU#VXSSO\#V\VWHP#GHVFULSWLRQ
Cadac consoles are designed to allow the use of two independent power supply sys-
tems in a redundant configuration – “main” and “backup”. Both sets of power supply
units are used to power the console system so that under normal conditions, the
‘load’is sharedbetween the “main” and “backup” PSU’s.If a fault occurs in one of the
power units (causing it to ‘shut-down’), the remaining power unit will power the con-
sole.
For smaller J -Type consoles (consuming no more than 44A), it is possible to use the
8400 PSU. See 1.3.7 8400 Switch-Mode Power Supply Unit.
One ±18V PSU and one +13V/+48V PSU is referred to as a “PSU System”.
Designate one pair of power supply units as “SYSTEM 1" and the other as “SYSTEM
2". PSU System 1 and PSU System 2 should be connected to the same
phase
and
on the same ‘spur’, wherever possible. In situations where it is necessary to provide
a separate ‘feed’ to each PSU system pair, make sure that the cable lengths are the
same. This is to minimize any induced a.c. power input noise by ensuring that the
“EARTH IMPEDANCE” is the same for both PSU systems.
/
1
(
/
1
(
/
1
(
/
1
(
-
-
-
-
$5($#%5$1&+#3$1(/
$5($#%5$1&+#3$1(/
$5($#%5$1&+#3$1(/
*1'#%$5 *1'#%$5
1#/
0$,1#*5281'#5()(5(1&(#($57+#(/(&752'(#6<67(0
FIG 1-2. AC mains grounding diagram (single phase 200-240V)
368#4$
368#4%
368#5$
368#5%

Connecting the mixer systems 1-3
Revision J2005-2 J-Type
The a.c.-input connectors on each power supply unit have three conductors: ‘LIVE’
(brown), ‘NEUTRAL’ (blue) and ‘EARTH’ (yellow/green). For safety and electromag-
netic compatibility considerations, it is essential that the ‘EARTH’ conductor is con-
nected on all PSUs and the a.c. supply has an ‘EARTH’ conductor that has a
continuous circuit to the “zero-signal reference potential” point in the building. The
ZSRP point in a building is usually found near the place where the a.c. ‘mains’ supply
enters the building (often referred to as the “MAIN GROUND REFERENCE EARTH
ELECTRODE SYSTEM”). The basic concept for correct a.c. mains wiring distribution
is shown in figure 1-1. If you need further information about this complex subject,
please refer to “Grounding Systems and their Implementation” by Charles Atkinson
and Philip Giddins published in the AES Journal Vol. 43, No. 6 – June 1995.
The grounding scheme in CADAC consoles is designed to meet the rigorous EEC
Electromagnetic Compatibility
requirements (EMC Directive - 1996). Any RF noise
induced in the console frame(s) is directed to the “local” ZSRP, which is the metal-
work of the power supply units. In order to take full advantage of the “RF noise immu-
nity” capability of the CADAC system, PSU a.c. mains cables and the a.c. mains
supply EARTH conductor must be connected correctly.
41615 $&#SRZHU#UHTXLUHPHQWV
CADAC power supply units are designed to run from a minimum of 208 V up to a
maximum of 260V, 50/60Hz a.c. In many parts of the world the normal a.c. single-
phase supply is 100-127V, this means that the CADAC power supply units must be
connected across two of the phases in the three-phase a.c. supply, see 1.3.4 Con-
necting to a 3-phase outlet.
41616 6ZLWFK00RGH#3RZHU#6XSSO\#8QLWV
CADAC 8019 and 8020 switch-mode power supply units are designed to run from a
minimum of 208V up to a maximum of 260V a.c, 50/60Hz.
The8019 “18V” unit is rated at 100A per railand the 8020“13V” unitis rated at 100A.
See also Appendices, B. Switch-Mode Power Supply Units
;34<#´4;9µ#VZLWFK0PRGH#SRZHU#VXSSO\#XQLW
The older version of 8019 ±18v unit is based on two ADVANCE F20006 ‘power-
blocks’, with additional circuitry as shown on CADAC drawing number C3.8015. The
new version is based on PowerOne PSUs (serial number 34949 onwards).
The a.c. input is connected to the PSU via a 3-core cable, CMA reference 3183TQ –
BASEC approved, rated at 20A.
FIG 1-3. 8019 power supply unit

1-4 Connecting the mixer systems
J-Type Revision J2005-2
;353#´469µ#VZLWFK0PRGH#SRZHU#VXSSO\#XQLW
The older version of 8020 +13v/48v unit is based on one ADVANCE F20006 ‘power-
block’, with additional circuitry as shown on CADAC drawing number C3.8016. The
new version is based onPowerOne PSUs (serial number 34949 onwards).
The a.c. input is connected to the PSU via a 3-core cable, CMA reference 3183TQ –
BASEC approved, rated at 20A.
5HSODFLQJ#D#SRZHU#VXSSO\#XQLW
If replacing a switch-mode power supply unit is required, please note the following:
■
■■
■Make sure that the power supply system’s power switches are in the position
OFF and disconnected from the mains.
■
■■
■The work should only be carried out by a suitably qualified electrician.
■
■■
■Be careful to observe correct polarity when connecting the new PSU.
■
■■
■Note that a console must never have one voltage without the other, for example
+18V must never be fed into the console without -18V.
When switching the power supply system back ON after replacement has taken
place, make sure that both LEDs on the front of the PSU-system come on. If only
one LED comes on, let go of the ON push-button immediately. Failure to do so may
lead to fire hazardand major damage to the console.
NOTE: Under no circumstances, should the 8019 or 8020
PSU be used without a SAFETY EARTH connection. Failure
to follow this instruction is both a fire and safety hazard.
FIG 1-4. 8020 power supply unit

Connecting the mixer systems 1-5
Revision J2005-2 J-Type
41617 &RQQHFWLQJ#WR#D#60SKDVH#RXWOHW
Connection to a 3-phase outlet is required on sites where the system voltage
between any one of the phases and neutral is 100-127V and the voltage between
any two of the phases is 200-240V. Before connecting to any 3-phase outlet, please
refer to a qualifiedelectrician who understands your particular installation and the
local safety and wiring regulations. Under no circumstances should the 8019 and
8020 switch-mode power supply units be operated without the green/yellow safety
earth conductor connected to the building safety earth conductor system. Each
power unit is equipped with an input supply filter whose reference ground conductor
is the chassis. Failure to connect the green/yellow safety earth conductor to the cor-
rect earth/ground building reference is a safety and fire hazard.
1. Connect the LIVE (Brown) conductor on the “system 1” 8019 unit to the phase 1
(L1, RED) terminal on the 3-phasepower outlet connector.
2. Connect the NEUTRAL (Blue) conductor on the “system 1” 8019 unit and the
LIVE (Brown) conductor on the “system 1” 8020 unit to the Phase 2 (L2, YEL-
LOW) terminal on the 3-phase power outlet connector.
3. Connect the NEUTRAL (Blue) conductor on the “system 1” 8020 unit to the
Phase 3 (L3, BLUE) terminal on the 3-phase power outlet connector.
4. Connect the EARTH (Yellow/Green) conductor on the “system 1” 8019 unit and
theEARTH(Yellow/Green) conductor on the“system1 “8020 unitto the SAFETY
EARTH (Yellow/Green) terminal on the 3-phase power outlet connector.
5. Repeat 1-4 for the “system 2” power units.
/LYH
1HXWUDO
(DUWK
/LYH
1HXWUDO
(DUWK
/LYH
1HXWUDO
(DUWK
/LYH
1HXWUDO
(DUWK
;34<
;353
;34<
;353
3+$6(#4#+/4/#5(',
3+$6(#5#+/5/#<(//2:,
3+$6(#6#+/6/#%/8(,
/4
/5
6$)(7<#($57+ /4
/5
6$)(7<#($57+
6$)(7<#($57+
<(//2:2*5((1
NOTE: Connection between two phases in a 3-phase outlet should under no
circumstances be carried out where the single-phase voltage (the voltage
between one of the phases and neutral) exceeds 127V. The installation
should be carried out by a qualified electrician who understands your partic-
ular installation and the local safety and wiring regulations.
FIG 1-5. Connecting to a 3-phase outlet
(100-127V/200-240 system voltages)

1-6 Connecting the mixer systems
J-Type Revision J2005-2
41618 0DLQ#DQG#H[WHQVLRQ#IUDPH#SRZHU#FRQQHFWLRQV
See fig 1-6 below for schematics of the frames power connections.
1. Using a short U-LINK cable (supplied), connect one of the outputs on the ±18V
PSU to one of the outputs on the +13V/+48V PSU in the “SYSTEM 1" power
supply rack. This operation “links” the d/c outputs on both power supply units in
the rack so that ±18V, +13V and +48V is available on all remaining output con-
nectors on either power unit.
2. Connect the second short “U-LINK” cable (supplied)between the ±18V PSU and
the +13V/+48V PSU’s in the “SYSTEM 2" power supply rack.
3. Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the MAIN FRAME.
4. Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the MAIN FRAME.
5. Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the EXTENSION FRAME 1.
6. Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the EXTENSION FRAME 1.
7. Repeat procedures 5. and 6. for EXTENSION FRAME 2 (a 3 frame console).
FIG 1-6. Power connections
368#6<67(0#4#+“4;9,
368#6<67(0#5#+“4;9,
368#6<67(0#4#+7;92.469,368#6<67(0#5#+7;92.469,

Connecting the mixer systems 1-7
Revision J2005-2 J-Type
41619 ;34<#DQG#;353#FRPELQHG#5HPRWH#VWDUW
Each 8019 and 8020 switch-mode power supply is fitted with a front panel mounted 9
way ‘D-type’ connector. This connector is labelled “Connections for Remote Start”.
You may connect a single remote start switch to each unit, have one switch start a
“system” pair, or wire up a single switch to start “system 1” and “system 2” all at the
same time.
Fig 1-7 applies to 8019 and 8020 PSUs up to serial number 34949 and shows the
circuit for starting up a “system” pair with a single switch. This has proved to be the
most popular method of connecting the remote start facility. This circuit can easily be
extended to provide a single switch remote for all four PSUs if required.
For 8019 and 8020 PSUs from serial number 34950 onwards, see fig 1-8 and 1-9.
NOTE:
■
■■
■The remote must be a ‘momentary’ type. You will need a two-pole switch for a
single PSU, a four-pole switch for a “system” pair, or a six-pole switch for controlling
all four units.
■
■■
■The remote switch(es) must be mounted on a metal panel.
■
■■
■Use shielded cable for the remote switch wiring.
■
■■
■The 9-way ‘D-type’ free plug must have a conductive shell. This is to ensure that
the cable shield connects directly to the PSU unit chassis.
■
■■
■Connect the cable shield to the metal panel where the remote start switch(es)
are mounted.
Great care must be taken with the wiring of the switch(es) to ensure that no short-cir-
cuits can occur between any two power supply units.
FIG 1-7. Remote start of 8019/8020 up to serial number 34950
PANEL MOUNTED 4-POLEVIEW FROM SOLDER
CUP/TAG SIDE
5
9
4
8
3
2
6
1
7
5
9
4
8
3
2
6
1
7
MOMENTARY SWITCH
TO CONNECTION
FOR REMOTE START
ON 8019 FRONT PANEL
TO CONNECTION
FOR REMOTE START
ON 8020 FRONT PANEL
NOTE: CABLE SCREEN IS
CONNECTED AT BOTH ENDS

1-8 Connecting the mixer systems
J-Type Revision J2005-2
300R
300R
18V
“START” MOMENTARY PUSH BUTTON
VIEW FROM SOLDER
CUP/TAG SIDE
OVER
TEMPERATURE
POWER FAILURE
5
9
4
8
3
2
6
1
7
FIG 1-8. Remote start of 8019 PSU
(from serial number 34950)
300R
300R
13V
“START” MOMENTARY PUSH BUTTON
VIEW FROM SOLDER
CUP/TAG SIDE
OVER
TEMPERATURE
POWER FAILURE
5
9
4
8
3
2
6
1
7
FIG 1-9. Remote start of 8020 PSU
(from serial number 34950)

Connecting the mixer systems 1-9
Revision J2005-2 J-Type
4161: ;733#VZLWFK0PRGH#SRZHU#VXSSO\#XQLW
CADAC 8400 switch-mode power supply units are designed to run from a minimum
of 208V up to a maximum of 260V a.c, 50/60Hz.
The 8400 is rated thus +13V@92A, ±18V@44A and 48V@5A.
The a.c. input is connected to the PSU via a 3-core cable, CMA reference 3183TQ –
BASEC approved, rated at 20A.
The 8400 unit is based on one POWER ONE RPMS-ETETGDGD1ETK Power block,
with additional circuitry as shown on CADAC drawing number C3.8397.
4161; 5HPRWH#VWDUW#RI#;733#368
Each 8400 switch-mode power supply provides the following outputs: 13v, ±18v and
48v. Each PSU is fitted with a front panel mounted 9-way'D-type’ connector labelled
‘Connections for Remote Start’. If a remote start facility is used, Power Failure and
Over-Temperature LEDs may also be fitted with the remote start switches if required.
Fig 3-15 shows the circuit for starting up a “system” with a single switch. This has
proved to be the most popular method of connecting the remote start facility. This cir-
cuit can easily be extended to provide a single switch remote for all four PSUs if
required. If muliple switches are to be used, see fig 3-14.
NOTE:
■
■■
■The remote start switch must be a ‘momentary’ type. You can use 3 separate sin-
glepole switches for each Power Supply to turn on 13v,±18v and 48v outputs of the
PSU alternativelyuse one single pole for all voltages.
■
■■
■The remote switch(es) must be mounted on a metal panel.
■
■■
■Use shielded cable for the remote switch wiring.
■
■■
■The 9-way ‘D-type’ free plug must have a conductive shell. This is to ensure that
the cable shield connects directly to the PSU unit chassis.
■
■■
■Connect the cable shield to the metal panel where the remote switch(es) are
mounted.
FIG 1-10. 8400 power supply unit.

1-10 Connecting the mixer systems
J-Type Revision J2005-2
Great care must be taken when wiring the switch(es) to ensure that no short-circuits
can occur between any two power supply units.
FIG1-11. Remotestartof
PSU 8400 with multiple
switches.
FIG 1-12. Remote start of PSU
8400 with a single switch

Connecting the mixer systems 1-11
Revision J2005-2 J-Type
417 &RQQHFWLQJ#WKH#FRQVROH#IUDPHV
41714 $XGLR#%XV#2#'DWD#%XV#&RQQHFWLRQV
If the console is used in a multi-frame configuration then the busses need to be con-
nected in a ‘daisy chain’ fashion.
Each end
of a frame has seven bus connectors -
four audio and two data busses plus fader bus . The bus cables are simply linked
between similar connectors on the end of the nearest frame.
Make sure that each frame has its “Frame Select” switch set to a different number.
See also Appendices, A. Important information regarding EMC.
41715 )DGHU#FRPPXQLFDWLRQV
When motor faders are used in extension frames, a 9-way “FADER COMMS” cable
must be connectedbetween the CCM connectorsshown and the COMMS input (see
fig 2-3) on the extension frame rear panel.
Extension frames fitted with motor-faders require control data from the CCM. Three
9-pin female connectors Three 9-pin female connectors located on the rear panel of
the CCM are connected directly to the extension frame using the supplied ‘fader
comms’ cable. The frame containing the CCM sends motor data fader data, via the
7303 interface module (always mounted directly below the CCM on J-type consoles).
Thus, a 3 frame console would require two “FADER COMMS” cables:
“FADER COMMS on EXTENSION FRAME 1 TO “FADER COMMS 2” on CCM
“FADER COMMS on EXTENSION FRAME 2 TO “FADER COMMS 3” on CCM
41716 3)/
PFL mixing amplifiers are located in the “Oscillator/Communications” module. There
are two PFL outputs:
■
■■
■PFL Direct is a line level output that appears on an XLR 3-32 connector on the
rear panel of the OSC/Comms module, labelled “PFL DIRECT”;
■
■■
■PFL to Headphones is a high level output suitable for driving headphones that
appears on an XLR 3-32 connector and a TRS jack socket connector on the rear
panel of the OSC/Comms module, labelled “PFL TO HP”.
4
56
7
)5$0(#6(/(&7
$8',2#%86#)5$0(#72#)5$0( $8',2#%86#)5$0(#72#)5$0( '$7$#&211(&725 &2006#&2111#
72#&&0
4
5
6
7
$
%
/,1.#7+(6(#&211(&7256
72#7+(#$'-$&(17#&211(&7256
21#7+(#1(;7#)5$0(
6(7#7+(#³)5$0(#6(/(&7´
6:,7&+#72#$#81,48(#180%(51
7+(#)5$0(#&217$,1,1*#7+(
&&0#,6#$/:$<6#)5$0(#41
:+(1#$#)5$0(#'2(6#127#&217$,1
7+(#&&0#%87#'2(6#+$9(#02725
)$'(56/#&211(&7#$#)$'(5#&2006
&$%/(#)520#7+(#&&0#72#7+(#)5$0(1
'$7$#&211(&725
$
%
)$'(5#%86
FIG 1-13. Audio/Data Bus connections.

1-12 Connecting the mixer systems
J-Type Revision J2005-2
The PFL to Headphones signal can be connected to the TRS jack sockets mounted
on the front of the console frame by using the “OSC/COMM TO FRAME” cable sup-
plied. This cable has a male XLR 3-pin connector on one end and a female XLR 3-
pin on the other end. Connect one end of the “Oscillator/Communications” module’s
“PFL TO HP” connector and the other end to the rear frame connector labelled
“FROM PFL HEADPHONE XLR”.
Additional inter-frame connections are required to enable the PFL signals from mod-
ules in extension (side) frames to be monitored. Use the cable(s) labelled “PFL
FRAME TO FRAME” to interconnect two or more frames:
■
■■
■Connect one end of a “PFL FRAME TO FRAME” cable to the connector labelled
“TO NEXT FRAME” on the console frame containing the “Osc/Communications”
module.
■
■■
■Connect the other end of a “PFL FRAME TO FRAME” cable to the connector
labelled “FROM PFL HEADPHONE XLR” on the next frame.
Repeat this procedure for all other frames in the console system.
41717 /LWWOLWHV
Surface illumination of the console is provided by the use of two or more “Littlite”
units that plug into the top bar of the console frame. Control for the “Littlites” - on/off
and intensity - is located on the “Oscillator/Communications” module. The variable
voltage power supply is mounted inside the console frame.
Two cables are required to interconnect the “Littlite” controls, the variable voltage
power supply and the lamp units.
■
■■
■Connect one of the cable labelled “OSC TO LITTLITES” to the connector on the
rear panel of the “Oscillator/Communications” module labelled “LITTLITES” (this
cable has 4-pin XLR male and female connectors).
■
■■
■Connect the other end of the cable labelled “OSC TO LITTLITE” to the connector
on the rear panel of the console frame labelled “FROM PFL MODULE”;
■
■■
■Connect one end of the cable labelled“LITTLITE FRAME TO BAR” to the con-
nector on the rear panel of the console frame labelled “TO LIGHTS” (this cable has a
4-pin male XLR connector at one end and a 5-pin XLR connector at the other end).
■
■■
■Connect the other end of the cable labelled“LITTLITE FRAME TO BAR” to the
5-pin XLR-connector mounted at the rear of the top bar on the console frame.
Additional inter-frame connections are required to enable the LITTLITE control sig-
nals to be delivered to any extension frame(s) in the console system. Use the
cable(s) labelled “LITTLITE FRAME TO FRAME” to interconnect two or more frames.
■
■■
■Connect one end of a “LITTLITE FRAME TO FRAME” cable to the connector
labelled “TO NEXT FRAME” on the console frame containing the “Oscillator/Commu-
nications” module;
■
■■
■Connect the other end of a “LITTLITE FRAME TO FRAME” cable to the connec-
tor labelled “FROM PFL MODULE” on the next frame;
■
■■
■Connect one end of a cable labelled “LITTLITE FRAME TO BAR” to the connec-
tor on the rear panel of the console frame labelled “TO LIGHTS” (this cable has a 4-
pin male XLR connector at one end and a 5-pin XLR connector at the other end.
■
■■
■Connect the other end of a cable labelled “LITTLITE FRAME TO BAR” to the 5-
pin XLR connector mounted at the rear of the top bar on the console frame.
Repeat this procedure for all other frames in the console system.
41718 368#,QGLFDWRU
Two sets of four LEDs are incorporated into the CCM front panel to give the operator
visual indication that the “main” (PSU System 1) and “backup” (PSU System 2)
power supply units are working correctly. A cable, labelled “PSU IND.” is supplied to
interconnect the CCM and the console frame.
Table of contents
Other Cadac Music Mixer manuals