INSTALLATION MANUAL ATB100 WI-FI THERMOSTAT
1 2
ENGLISH
REVISION 1.7
WARNING
•Read the instructions before installing and using this product.
•The product should not be used with different functions other than those described below.
•Warning: before proceeding with the installation, turn off the power supply from the system.
•For the use of the product it is necessary to have a WIFI network.
•For the use of the product it is necessary to have a smartphone or Tablet with internet connection.
•Install the thermostat Campini at a height of 1.5 meters above the ground in a suitable position to correctly
detect the ambient temperature, possibly on an internal wall, avoiding the installation near doors, windows,
curtains or near heat sources.
•Install the router Campini within the range of domestic WIFI network.
•The maximum reception distance between Campini Router and Campini Thermostat in open air is about 100
meters. Obstacles between Router and Thermostat, such as walls or shielding materials, reduce the
reception distance.
SHIPPING CONTENTS
1 Campini thermostat 1 Campini Router 3 AAA batteries 1.5V
INSTALLATION
The list below shows step by step how to install and activate the Campini thermostat and Router:
1) Caution: remove the electric current from the system.
2) Remove the old thermostat.
3) Locate the control cables.
If the old thermostat is equipped with 2 wires, then those will be the control cables to be connected to the Campini
Thermostat
If the old thermostat has 4 wires, it will be sufficient to recognize the control cables from the power ones. While the
control cables will be used to install the Campini Thermostat, the power cables must be isolated as they will not be
used.
4) Separate the Campini Thermostat from the relative plate. To do this, simply insert a suitable tool into the slot on
the right side of the Campini Thermostat and exert a slight pressure until the front of the device separates from the
plate.
5) Attach the Campini thermostat plate to the wall.
INSTALLATION MANUAL ATB100 WI-FI THERMOSTAT
3 4
6) Screw the control cables in the terminal on the plate of the Campini thermostat (see the label for the correct wiring).
Attention: At the end of the wiring, cover the terminal board screws with the supplied label.
7) Insert 3 AAA batteries into the Campini thermostat.
8) Engage the Campini thermostat in the plate previously fixed to the wall.
Press the two buttons (+) and (-) to switch on or switch off the Campini Thermostat.
9) Restore the electric current of the plant.
Before proceeding, it is advisable to check the wiring carried out through the Campini thermostat:
•Using the "+" button, raise the setpoint until you see the symbol on the screen. Check that the system is
turned on.
•Using the "-" button, decrease the setpoint until the symbol disappears from the screen; from the activation
of the system and the next switch-off it is necessary that a few minutes pass depending on the value set in
parameter "minimum ‘on’ time of the relay". Make sure the plant is off.
If the plant is switched on and off correctly, then you can continue with the installation procedure. Otherwise, it is
necessary to remove the electric current from the system, remove the thermostat from the previously fixed wall
plate and check the wiring of the control cables.
APP
To configure the Campini Thermostat, visit the website atb100.campinicorel.it and download the Campini Corel
Thermostat application on smartphone or tablet.
SUPPORT
If necessary, you can consult the Internet address atb100.campinicorel.it.
If you cannot find a solution to your problem, you can contact the technical assistance by writing an email to the email
address support@campinicorel.it.
TECHNICAL SPECIFICATIONS
CAMPINI THERMOSTAT
•Power supply: 3 AAA alkaline batteries (LR03), Duration: about 1 year
•Size: 115x80x27 mm
•Temperature measurable: from 0 ° C to 50 ° C (Resolution: ± 0.1 ° C)
•Setting temperature: 5 ° C to 35 ° C (Resolution: ± 0.1 ° C)
•Maximum switching current: 8 A
•Maximum switching voltage: 250 Vac / 30 Vdc
•Operating temperature: from 0 to 40 ° C
•Relative Humidity: Max 85% (non-condensing)
•Transport temperature: from -10 to 50°C
•Protection Degree: IP20
•RF connection: 868 MHz
•Control cables: maximum Ø 1,5mm
•Type of action: 1B
•Pollution degree: 2
•Impulse voltage: 4000V
•Software: Class A
•Electrical insulation: Class II
CAMPINI ROUTER
•Power supply: 100-240VAC 50 / 60Hz
•Power consumption: 45mA Max
•Size: 103x62x60 mm
•Operating temperature: from 0 to 60 ° C
•Relative Humidity: Max 85% (non-condensing)
•Transport temperature: from -10 to 60 ° C
•Protection Degree: IP40
•WI-FI: IEEE 802.11 b / g / n 2.4 GHz
•RF Connection: 868 MHz
•Type of action: 1B
•Pollution degree: 2
•Impulse voltage: 4000V
•Software: Class A
•Electrical insulation: Class II
ENERGY EFFICIENCY CLASS (ErP)
Supplier name or trademark: Temperature Campini - Corel SpA
Vendor identifier model: ATB100
Class of temperature control: IV
Contribution of temperature control of Energy Efficiency: 2%
The manufacturer, Termoregolatori Campini-Corel Spa, declares that the ATB100 radio equipment device complies with the
2014/53/EU Directive. The complete text of the Eu declaration of conformity is available at the following Internet
address: atb100.campinicorel.it/UE.pdf.
The WEEE symbol means that according to local laws and regulations your product and / or its battery should be recycled
separately from household waste. When the product becomes unusable, take it to a collection point designated by local
authorities. The separate collection and recycling of your product and / or its battery at the time of disposal will help conserve
natural resources and ensure that recycling takes place in respect of human health and the environment.
Termoregolatori Campini - Corel S.p.A.
Via Don Guanella 14, 22066 Mariano Comense (CO), ITALY
MADE IN ITALY

Other manuals for ATB100

1

Other Campini Corel Thermostat manuals

Campini Corel ATB100 User manual

Campini Corel

Campini Corel ATB100 User manual

Campini Corel TS9510 User manual

Campini Corel

Campini Corel TS9510 User manual

Popular Thermostat manuals by other brands

VDH ALFA 33 DP user manual

VDH

VDH ALFA 33 DP user manual

Furrion FACW10SA-BL quick start guide

Furrion

Furrion FACW10SA-BL quick start guide

CLIVET HID-TConnect quick guide

CLIVET

CLIVET HID-TConnect quick guide

Johnson Controls KONOzw Operation guideline

Johnson Controls

Johnson Controls KONOzw Operation guideline

Ideal Boilers touch quick start guide

Ideal Boilers

Ideal Boilers touch quick start guide

Regin RCFM-230D Instruction

Regin

Regin RCFM-230D Instruction

Honeywell Q682B manual

Honeywell

Honeywell Q682B manual

Sangamo CHPWIFI user manual

Sangamo

Sangamo CHPWIFI user manual

HOTOWELL HTW-91-WT416-X8 manual

HOTOWELL

HOTOWELL HTW-91-WT416-X8 manual

HAI RC-1000 user guide

HAI

HAI RC-1000 user guide

Tekmar 530 user manual

Tekmar

Tekmar 530 user manual

Giacomini KPM10 manual

Giacomini

Giacomini KPM10 manual

White Rodgers 1F86-344 Installation and operation instructions

White Rodgers

White Rodgers 1F86-344 Installation and operation instructions

RCS TBZ48A installation guide

RCS

RCS TBZ48A installation guide

Honeywell T7351 user guide

Honeywell

Honeywell T7351 user guide

Bryant T2SNAC01 installation instructions

Bryant

Bryant T2SNAC01 installation instructions

ComfortNET CTK01 Installation and start-up instructions

ComfortNET

ComfortNET CTK01 Installation and start-up instructions

Nexans MILLITEMP CDFR-003 User's manual & installation instructions

Nexans

Nexans MILLITEMP CDFR-003 User's manual & installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.