CAN FL1400 Quick start guide

CAN S.r.l.
Via Nazionale 65,
25080 - Puegnago del Garda (BS) ITALY
T. +39 0365 555909
F. +39 0365 651822
www.cansrl.com
DE
HANDBUCH FÜR INSTALLATION,
GEBRAUCH UND WARTUNG
serie FL
IT
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
EN
INSTALLATION, USE AND
MAINTENANCE INSTRUCTION MANUAL
FR
MANUEL D’INSTRUCTIONS D’INSTALLATION-
D’UTILISATION-ET D’ENTRETIEN
ES
MANUAL DE INSTRUCCIONES
INSTALACIÓN-USO-MANTENIMIENTO

2
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
Thank you for having purchased our cooking device CAN S.r.l.
This is a quality appliance, made in Italy, capable of reliably and safely keeping you company on your
vacation and leisure time, always guaranteeing high level performance.
Installation and use of the device are simple and straightforward.
Please read this manual carefully: this will allow you to install and use your appliance correctly, always
keeping it in perfect working order for years. The instructions in this booklet only apply to the Country
of destination. The gas supply systems must meet current national standards.
The following symbols have been used in the manual to make it easier to read:
SAFETY-RELATED WARNINGS FOR INSTALLERS AND USERS
Failure to comply with these warnings can cause material damage and jeopardise operation of
the appliance.
GENERAL INFORMATION
Additional information for installers and users.
CAN S.r.l., as manufacturer of the appliance, reserves the right to make changes to its products and to
this manual considered appropriate, without being obliged to give prior notice. The drawings, installation
diagrams and tables in the manual are to be considered indicative and exclusively for explanatory purposes.
CAN S.r.l. prohibits fully or partially copying or reproducing the contents of this manual or forwarding it to
third parties without consent of the Manufacturer.
revision index
Edition 05/2018 Revision 00

3
ENGLISH
DECLARATION OF CONFORMITY
CAN S.r.l.
Italian company with headquarters at:
Via Nazionale, 65 – 25080, Puegnago del Garda ( BS) – ITALY
VAT NO. 03607980988 – REA BS548442
DECLARES THAT
the products called
GAS HOB UNITS COMBINED WITH RECESSED SINK
FL SERIES – TYPE: FL13XX – FL14XX – FL17XX
Meet all the essential requirements of the GAD Directive – 2009/142/EEC of 30/11/2009 and also the
subsequent GAR regulation - 2016/426/EU of 09/03/2016, as well as the following regulations:
• EC regulation 1935/2004
• EU Regulation no.65/2014 – “ENERGY LABEL”
• EU Regulation no.66/2014 – “ECODESIGN”
Our devices are also manufactured in compliance with all relevant harmonised technical standards for the
sector, in particular:
• EN 30-1-1: 2008 + A3 02/2013
• EN 30-2-1: 2015
We hereby declare that all the products of the FL SERIES, are built according to the specifications of the
samples described in:
TYPE no. 51CO4387 TEST CERTIFICATE issued by IMQ S.p.a.
as notified body, with identification number 0051
The undersigned, Lorenzo Bellini, as director of the company CAN S.r.l., assumes full responsibility for the
truthfulness of the declarations herein.
Puegnago del Garda, 26/03/2018
Signature: Lorenzo Bellini

4
ENGLISH
TABLE OF CONTENTS
TECHNICAL DATA SHEET: FL1323 - FL1324 6
TECHNICAL DATA SHEET: FL1400 - FL1401 - FL1402 -
FL1410 8
TECHNICAL DATA SHEET: FL1765- FL1766 - FL1770 -
FL1780 10
INSTRUCTIONS FOR THE INSTALLER
GENERAL SAFETY WARNINGS 12
INTENDED USE 13
OBLIGATIONS AND PROHIBITIONS 13
OBLIGATIONS 13
PROHIBITIONS 13
IDENTIFICATION OF THE APPLIANCE 14
RECEPTION OF THE APPLIANCE 15
CONTROL AND HANDLING 15
DISPOSING OF THE PACKAGING 15
INSTALLATION ROOM 16
FEATURES OF INSTALLATION ROOM 16
FLUE GAS EXHAUST 16
INSTALLATION ON SUPPORT STRUCTURE 17
RECESSED HOLE 17
SAFETY DISTANCES 18
POSITIONING THE APPLIANCE 19
GAS CONNECTION 20
GAS CATEGORIES 20
CONNECTION PIPE REQUIREMENTS 20
GAS CONNECTION PROCEDURE 21
ELECTRICAL CONNECTION (ONLY FOR IGN VERSION) 21
TROUBLESHOOTING AFTER INSTALLATION 22
GENERAL PRELIMINARY INFORMATION

5
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
INSTRUCTIONS FOR USE
SPARE PARTS
DESCRIPTION 23
SAFETY WARNINGS DURING USE 27
USE 27
LIGHTING THE BURNERS 28
ADJUSTING THE FLAME 29
COOKING OR WARMING UP FOOD 29
SWITCHING OFF THE BURNER 30
OPERATING FAULTS 30
WHAT TO DO IN CASE OF MALFUNCTIONING 30
MAINTENANCE AND CLEANING 31
LONG IDLE PERIODS 32
WASTE DISPOSAL 32
WARRANTY 32
SPARE PARTS - FL13XX 33
SPARE PARTS - FL14XX 34
SPARE PARTS - FL17XX 35

6
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
TECHNICAL DATA SHEET: FL1323 - FL1324
FL1323
FL1324

7
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
Dimensions Width 530 mm
Depth 340 mm
Height 48 mm (hob area)
150 mm (sink area)
Weight 3.6 kg
Hob Unit
(straight valves with
bypass Ø 0.36 mm)
1 x burner SEMIRAPID (SR):
Pn 1.75 kW – injector ø 0.65 mm – consumption 127.0 g/h
Device Class
(EN 30-1-1 4.3)
CLASS 3 – Combined recessed hob unit
Device Category
(EN 30-1-1 5.1.1.2) CATEGORY I
Admitted Gases
family
(EN 437)
(EN 30-1-1 4.2.2.4)
GAS OF THE THIRD FAMILY
▪I3 B/P
▪I3+
Gas Supply CATEGORY I3 B/P
▪Butane (G30) 30 mbar
▪Propane (G31) 30 mbar
CATEGORY I3+
▪Butane (G30) 28-30 mbar
▪Propane (G31) 37 mbar
Electric Connection
(only for IGN version with
electronic lighting)
ELECTRIC CONNECTION IN EXTRA-LOW VOLTAGE - 12V / DC
Lighting
(different lighting systems
according to product
specifications)
▪STD (MANUAL) – using external igniter
▪IGN (ELECTRONIC) - 12 V/DC GENERATOR - SPARK - 10Kv @ 30 pF
▪PZ (PIEZOELECTRIC) – Mechanically/manually operated piezoelectric igniter
inserted in hob unit
Gas Connection Galvanised steel train: Ø 8 mm - 0.5 mm thick
smooth end piece (30 mm) suitable for press fitting connecting with rigid / flexible hose
Gas Capillaries Copper capillary pipes: ø 4 mm – 1 mm thick
Materials ▪Stainless steel AISI 304
▪Glass
▪Chromium-plated iron
▪Zama
▪Brass
▪Copper
▪Galvanised steel
▪Aluminium alloy
▪Enamelled steel
▪Epdm
Declaration of
Conformity
(Directive 2009/142/EC
and GAR 2016/426/EC)
▪no asbestos
▪suitable materials according to chapters 2 and 3 (Annex I - 2016/426/EC)
▪there are no welds with melting point lower than 450°C
▪flammable materials were not used
▪the materials are suitable according to the requirements of chapter 3.7
TECHNICAL DATA SHEET: FL1323 - FL1324

8
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
TECHNICAL DATA SHEET: FL1400 - FL1401 - FL1402 -
FL1410
FL1400
FL1410
FL1401
FL1402

9
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
Dimensions Width 716 mm
Depth 340 mm
Height 48 mm (hob area)
150 mm (sink area)
Weight 5.5 kg
Hob Unit
(straight valves with
bypass Ø 0.36 mm)
1 x AUXILIARY burner (AUX)
Pn 1.00 kW – injector ø 0.50 mm – consumption 72.50 g/h
1 x burner SEMIRAPID (SR):
Pn 1.75 kW – injector ø 0.65 mm – consumption 127.0 g/h
Device Class
(EN 30-1-1 4.3)
CLASS 3 – Combined recessed hob unit
Device Category
(EN 30-1-1 5.1.1.2) CATEGORY I
Admitted Gases family
(EN 437)
(EN 30-1-1 4.2.2.4)
GAS OF THE THIRD FAMILY
▪I3 B/P
▪I3+
Gas Supply CATEGORY I3 B/P
▪Butane (G30) 30 mbar
▪Propane (G31) 30 mbar
CATEGORY I3+
▪Butane (G30) 28-30 mbar
▪Propane (G31) 37 mbar
Electric Connection
(only for IGN version with
electronic lighting)
ELECTRIC CONNECTION IN EXTRA-LOW VOLTAGE - 12V / DC
Lighting
(different lighting systems
according to product
specifications)
▪STD (MANUAL) – using external igniter
▪IGN (ELECTRONIC) - 12 V/DC GENERATOR - SPARK - 10Kv @ 30 pF
▪PZ (PIEZOELECTRIC) – Mechanically/manually operated piezoelectric igniter
inserted in hob unit
Gas Connection Galvanised steel train: Ø 8 mm - 0.5 mm thick
smooth end piece (30 mm) suitable for press fitting connecting with rigid / flexible hose
Gas Capillaries Copper capillary pipes: ø 4 mm – 1 mm thick
Materials ▪Stainless steel AISI 304
▪Glass
▪Enamelled steel
▪Zama
▪Brass
▪Copper
▪Galvanised steel
▪Aluminium alloy
▪Epdm
Declaration of
Conformity
(Directive 2009/142/EC
and GAR 2016/426/EC)
▪no asbestos
▪suitable materials according to chapters 2 and 3 (Annex I - 2016/426/EC)
▪there are no welds with melting point lower than 450°C
▪flammable materials were not used
▪the materials are suitable according to the requirements of chapter 3.7
TECHNICAL DATA SHEET: FL1400 - FL1401 - FL1402 - FL1410

10
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
TECHNICAL DATA SHEET: FL1765- FL1766 - FL1770 -
FL1780
FL1765
FL1766
FL1770
FL1780

11
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
Dimensions Width 765 mm
Depth 355 mm
Height 48 mm (hob area)
150 mm (sink area)
Weight 5.0 kg
Hob Unit
(straight valves with
bypass Ø 0.36 mm)
1 x AUXILIARY burner (AUX)
Pn 1.00 kW – injector ø 0.50 mm – consumption 72.50 g/h
1 x burner SEMIRAPID (SR):
Pn 1.75 kW – injector ø 0.65 mm – consumption 127.0 g/h
Device Class
(EN 30-1-1 4.3)
CLASS 3 – Combined recessed hob unit
Device Category
(EN 30-1-1 5.1.1.2) CATEGORY I
Admitted Gases family
(EN 437)
(EN 30-1-1 4.2.2.4)
GAS OF THE THIRD FAMILY
▪I3 B/P
▪I3+
Gas Supply CATEGORY I3 B/P
▪Butane (G30) 30 mbar
▪Propane (G31) 30 mbar
CATEGORY I3+
▪Butane (G30) 28-30 mbar
▪Propane (G31) 37 mbar
Electric Connection
(only for IGN version with
electronic lighting)
ELECTRIC CONNECTION IN EXTRA-LOW VOLTAGE - 12V / DC
Lighting
(different lighting systems
according to product
specifications)
▪STD (MANUAL) – using external igniter
▪IGN (ELECTRONIC) - 12 V/DC GENERATOR - SPARK - 10Kv @ 30 pF
▪PZ (PIEZOELECTRIC) – Mechanically/manually operated piezoelectric igniter
inserted in hob unit
Gas Connection Galvanised steel train: Ø 8 mm - 0.5 mm thick
smooth end piece (30 mm) suitable for press fitting connecting with rigid / flexible hose
Gas Capillaries Copper capillary pipes: ø 4 mm – 0.5 mm thick
Materials ▪Stainless steel AISI 304
▪Glass
▪Chromium-plated steel
▪Zama
▪Brass
▪Copper
▪Galvanised steel
▪Aluminium alloy
▪Enamelled steel
▪Epdm
Declaration of
Conformity
(Directive 2009/142/EC
and GAR 2016/426/EC)
▪no asbestos
▪suitable materials according to chapters 2 and 3 (Annex I - 2016/426/EC)
▪there are no welds with melting point lower than 450°C
▪flammable materials were not used
▪the materials are suitable according to the requirements of chapter 3.7
TECHNICAL DATA SHEET: FL1765- FL1766 - FL1770 - FL1780

12
ENGLISH
GENERAL PRELIMINARY INFORMATION
Read these instructions carefully before installing and/or using the appliance.
This installation, use and maintenance instruction manual is an integral part of the appliance. Keep this
documentation in a place which all users may have access for future consultation. If the appliance is
transferred or sold, make sure that this booklet is also delivered to the new user in order to know its
installation, use and safety prescriptions.
GENERAL SAFETY WARNINGS
ATTENTION!
CAN S.r.l. will not be held liable for any use other than that indicated. Do not use this appliance
as a space heater.
ATTENTION!
Do not modify the appliance, unless the change is authorised and carried out by the
Manufacturer or by his authorised technicians.
ATTENTION!
CAN S.r.l. will not be held liable for personal harm or property damage caused by failure to
comply with the above-mentioned provisions or resulting from tampering with even a single
part of the appliance and using non-original spare parts.
ATTENTION!
Wear the proper personal protective equipment during installation. Also follow the applicable
safety standards.
ATTENTION!
Gas and electric appliances must only be installed by qualified and certified professionals.
ATTENTION!
Make sure that the type of gas and pressure match the specifications of the appliance. The
specifications are shown on the data plate.
ATTENTION!
Pay the utmost attention to standards regarding ventilation of the installation rooms, currently
in force in the country of use.
ATTENTION!
If it is not possible to assemble the device according to the instructions herein, contact
CAN S.r.l.
ATTENTION!
Only replace failed or faulty components with original spare parts CAN S.r.l.
ATTENTION!
Do not close the glass lid when the burners are lit or still hot.

13
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
ATTENTION!
Do not allow the cooking vessels to come into contact with the glass lids, the hinges or other
plastic components while the device is in use.
INTENDED USE
The appliance is intended to cook and warm up food. Any other use must be considered improper.
CAN S.r.l. will not be held liable for any use other than that indicated.
▪Do not use the appliance outdoors.
▪Do not use this appliance as a space heater.
ATTENTION!
Use of a gas fired appliance produces heat and humidity in the room it is installed in. Always
guarantee proper ventilation of the rooms keeping air vents/intakes or windows open. If this
is not enough, install a mechanical ventilation/extraction device of combustion products (e.g.
extractor hood).
ATTENTION!
The appliance is equipped with a glass lid. Glass lids can shatter if overheated or struck by
sharp objects. Always open the lid before lighting any burner, making sure to switch off the
burners and let them cool off a few minutes before reclosing the glass lid at the end of each
operating cycle.
OBLIGATIONS AND PROHIBITIONS
OBLIGATIONS
▪The appliance’s installation site must have a regulation ventilation system, according to standards
in the sector, be in good maintenance condition and proper working order, as well as appropriately
dimensioned for the purpose.
▪Follow the instructions in chapter "Instructions for the installer" when installing the appliance.
Installation must only be carried out by qualified technical personnel.
▪The appliance must only be used with the types of gas indicated in paragraph "Gas categories".
▪When operating the appliance, only use suitable pots and pans (refer to the specific paragraph)
on the appropriate pan supports supplied with the hob units. Make sure that these devices remain
perfectly horizontal and parallel to the hob, so that they do not tip over and risk causing burns and
scalding for the users. Burn hazard.
▪Always monitor the hob unit while operating and especially when cooking very greasy dishes or fried
food.
PROHIBITIONS
▪Do not install the appliance if damaged upon reception.
▪Never leave the appliance unattended while running.
▪Do not allow the appliance to be used by children younger than 14 years old or persons with reduced
physical, mental or sensory capabilities or without adequate knowledge.
▪The cooking areas and nearby surfaces become very hot. Do not touch high temperature surfaces.
Burn hazard.
▪Do not close the lid of the appliance while running.
▪Do not use vessels which are damaged, of an inappropriate size and/or which protrude beyond the
edges of the hob unit or are positioned improperly.

14
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
▪Do not heat empty pans or without a sufficient amount of cooking fluid.
▪Do not expose the appliance to air draughts. The burners could go out.
▪Do not force the knobs if blocked. Contact the Technical Assistance Service.
▪Do not place anything on top of the hob unit.
▪Do not modify or tamper with the appliance in any way.
▪Do not place heat sensitive or flammable objects (e.g. mitts, curtains, alcoholic beverages, etc.) near
the appliance.
IDENTIFICATION OF THE APPLIANCE
There is an identification label at the bottom of the appliance bearing:
▪serial number information,
▪typological/functional features,
▪certification data and CE marking.
The CE marking certifies that the product meets the requirements of EU regulation 2016/426
on appliances burning gaseous fuels.
ATTENTION!
The identification plate must not be removed.
1
9
3 11
10
8 7
425 6
pos.element
1Manufacturer Logo
2Manufacturer Address
3Name of appliance family
4Series and type
5Model
6EC certification serial number
7Operating pressures - Type-approval parameters - Countries
8Total power and consumption
9Barcode - Production serial number
10 Production data
11 CE marking applied by manufacturer

15
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
RECEPTION OF THE APPLIANCE
The appliance is delivered to the customer in a cardboard box (A), protected by shaped polystyrene shells
(B) to avoid damage during transport and storage.
In addition to the appliance, the box also contains:
▪the installation, use and maintenance manual (C),
▪a fixing kit (D) including screws and accessories for installation of the appliance on the support structure.
AB
D
C
CAN S.r.l.
Via Nazionale 65,
25080 - Puegnago del Garda (BS) ITALY
T. +39 0365 555909
F. +39 0365 651822
www.cansrl.com
DE
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
serie FL
IT
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
EN
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
FR
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
ES
MANUALE DI ISTRUZIONI
INSTALLAZIONE-USO-MANUTENZIONE
CONTROL AND HANDLING
Upon reception of the appliance, proceed to unpack it.
After having removed all the packaging material and protective film, check for any faults.
Should any faults be discovered, do not install the appliance and contact your Dealer within 8 days from
the date of purchase, reporting the data on the identification label of the appliance and the problems
encountered.
ATTENTION!
Do not leave unattended or release the packaging or parts of it into the environment because
they are potentially hazardous (risk of suffocation for children and animals).
Lift the appliance by hand to move it to the installation site.
ATTENTION!
During handling, make sure not to damage the appliance, persons, animals or objects in the
immediate vicinity.
DISPOSING OF THE PACKAGING
The materials used for packaging are recyclable and must be collected according to local standards on
separate waste collection.
ATTENTION!
Separate the different materials making up the packaging and dispose of them in compliance
with standards in force in the Country of installation.

16
ENGLISH
INSTRUCTIONS FOR THE INSTALLER
ATTENTION!
Installation and all the interventions on the appliance described in this instruction manual
must be carried out by qualified technical personnel and in compliance with standards in
force.
ATTENTION!
The gas connection systems and the installation rooms must be suitable and meet the safety
standards in force in the Country of use.
ATTENTION!
During installation, maintenance or repair operations, always close the main gas valves, so
that the gas supply line to the hob unit is "GAS FREE" and there is no risk of fire/explosion or
poisoning/suffocation.
ATTENTION!
Make sure the power line is also disconnected to avoid the risk of the installer being
electrocuted.
▪Do not install or use the appliance if damaged.
▪Respect the minimum distance from the walls and other equipment (see paragraph “Safety distances”).
▪The appliance is not connected to a combustion product extractor device. The user must make sure
that the appliance is installed in an environment with a high ventilation rate.
INSTALLATION ROOM
FEATURES OF INSTALLATION ROOM
The appliance was not designed to work outdoors. It is not allowed to install the appliance
outdoors and directly exposed to the elements.
The appliance must be installed indoors, in a room suitable for the purpose. The room was meet the safety
standards in force in the Country of use.
ATTENTION!
The installation rooms must have a continuous air exchange or at least such to guarantee normal
and correct gas combustion (according to standard UNI 7131 or other technical standards of
reference in the sectors of use, for example EN721 - EN1645-1 - EN1646-1 - EN1949 - EN ISO 10293).
FLUE GAS EXHAUST
The appliance is not equipped with an extraction/exhaust system of flue gas and combustion products.
Always check that there are proper ventilation vents in the room.
If a hood is installed above the hob unit, see the installation instructions of the hood which shows
the correct distance to be respected.

17
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
INSTALLATION ON SUPPORT STRUCTURE
The appliance must be mounted on a support structure, made of material resistant to heat and with all of
the sturdiness requirements indicated by the technical sector standards (for example EN14749). The work
table must be perfectly horizontal and perpendicular to all surrounding vertical panelling. The area in the
vicinity of the appliance could get very hot. Pay the utmost attention when placing sockets, other household
appliances, power cables, piping and any other heat sensitive or flammable material in this space.
ATTENTION!
The appliance must be installed in a room without air draughts which can have a negative
effect on combustion. The chosen installation position must also prevent the accumulation of
unburnt gases.
Comply with the sizes indicated in this manual. Any deviation could cause the temperature to rise excessively.
The surrounding surfaces must be able to withstand temperature rises admitted by standard EN30-1-1 and in
compliance with the design of this unit. All combustible material, such as curtains and shelves, must be kept
far away from the appliance. Check the admissible temperature of the materials used for the surrounding
surfaces to guarantee their compliance with the requirements of EN30-1-1.
RECESSED HOLE
The support structure must be provided with a suitable recessed hole. See the following table for the size
of the hole in reference to the purchased model:
sizes of recessed hole
model a
[mm]
b
[mm]
FL1323 520 320
FL1324 520 320
FL1400 700 320
FL1401 700 320
FL1402 700 320
FL1410 700 320
FL1765 740 325
FL1766 740 325
FL1770 740 325
FL1780 740 325
Details C
85 mm
R10
128 mm
R32
R70
FL13XX
85 mm
135 mm
R10
R32
R70
FL14XX
A
B
5 mm
8 mm
C
FL13XX - FL14XX

18
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
SAFETY DISTANCES
The appliance must be kept a certain distance away from side and upper walls. Consult the following table:
dimensions and minimum safety distances for installation
If the appliance is recessed above an oven or another
powered household appliance, a separation panel
must also be provided as indicated in point 1.
Remember to prepare adequate holes in the
furniture for passage of the gas pipe, water pipes
and electrical power of the appliance, if present.
model a
[mm]
b
[mm]
c
[mm]
d
[mm]
e
[mm]
FL1323 50 55 520 650 110
FL1324 50 55 520 650 110
FL1400 50 55 700 650 110
FL1401 50 55 700 650 110
FL1402 50 55 700 650 110
FL1410 50 55 700 650 110
FL1765 50 55 740 650 105
FL1766 50 55 740 650 105
FL1770 50 55 740 650 105
FL1780 50 55 740 650 105
max
150 mm
DAB
C
D
E
1
A
5 mm
B
FL17XX
R10
82 mm
R32
R40
R90
85 mm
5 mm
145 mm
FL17XX
D
Detail D

19
ENGLISHENGLISH
Installation, use and maintenance instruction manual ▪Ed. 05/2018 Rev. 00
POSITIONING THE APPLIANCE
Proceed as follows to position the appliance on the support structure:
step action
1 Position the gasket (sold separately) on the edges of the metal moulding or sealant paste (if present).
2 Position appliance on the recessed hole and push it onto the support structure.
3Secure the appliance using the fixing screws provided in the specific kit and screw them into the holes made
at the four corners of the metal moulding.
Note: make sure that the appliance is positioned properly in the slot before performing the final fixing.
ATTENTION!
There must be an opening below the hob of at least 50 x 50 mm for passage of the gas and
electrical connections.
EQUIPMENT REQUIRED
4 x 4 x
2
1
3

20
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK ▪ FL series
GAS CONNECTION
ATTENTION!
Before performing the connection, make sure that the gas system and the installation rooms
are suitable for the purpose and comply with standards in force in the Country of installation.
Refer to the specific technical standards regarding conformity of gas systems (LPG) for the
household (UNI CIG 7131 e 7129), nautical ( UNI EN ISO 10239) and recreational vehicles
sectors (UNI EN 1949).
Before connecting gas, check that:
▪the supply line is free from obstructions and has sufficient flow rate to guarantee correct operation
of the appliance;
▪there is a suitable pressure regulator/reducer compliant with the gas categories used on the appliance
immediately downstream of the gas cylinder or container feeding the system;
▪a gas shut-off valve or a valve disconnecting the system is installed on the supply line, downstream of
the regulator and immediately upstream of the appliance intended to connect, in a place which can
easily be accessed and inspected. (Please note: this valve must always be shut during installation and
maintenance on the appliance).
ATTENTION!
Make sure that the type of gas which will feed the appliance is among those allowed and listed
in the instruction booklet (see paragraph “Gas categories”).
GAS CATEGORIES
The appliance was designed for correct operation only with the types of gas categories and operating
pressures listed below:
gas category and country of
destination
name of gas operating pressure
I3B/P (30)
AT-BE-DE-DK-FI-GB-NL-NO-PT-SE-SI
Butane (G30)
Propane (G31)
30 mbar
30 mbar
I3+ (28-30/37)
BE-CH-ES-FR-GB-IE-IT-PT-SI
Butane (G30)
Propane (G31)
28 - 30 mbar
37 mbar
CONNECTION PIPE REQUIREMENTS
ATTENTION!
The appliance must be connected to the gas pipeline by means of a suitable connection pipe
making use of certified sealed fittings the type most suitable for the application.
It is possible to use flexible connection hoses. They must:
▪always be able to be inspected,
▪be protected against contact with hot parts (e.g. burner cups),
▪be protected from the movable parts of the recessing (drawers, doors, etc.),
▪have a length which complies with the technical standards for each sector of reference.
Avoid any type of mechanical stress on the flexible hoses during installation and use (protection against
traction, twisting, crushing, etc.).
ATTENTION!
Perform maintenance and periodically replace the flexible hose within the expiration date
written on the sheath. Do not use expired or damaged flexible hoses by any means.
This manual suits for next models
9
Table of contents
Other CAN Hob manuals