Important Information
Always consult your physician before starting
any bright light therapy regimen.
Read all instructions before using the Day-Light
Safety Precautions
1. As with any electrical device, do not use the Day-Light in or near water.
2. Do not overuse the Day-Light. Recommended usage is 20-30 minutes each morning. Overuse
may cause irritability, excessive energy, or diculty falling asleep at bedtime.
3. It is not necessary to stare into the light. Feel free to read, work, eat or talk on the phone
during your light therapy session.
4. During the rst few uses, your Day-Light may give o an odor; this is harmless. This will not
aect the use of your Day-Light and will quickly disappear.
5. Do not leave your Day-Light on for more than 60 minutes in Therapy mode. Always use in a
well-ventilated area away from other heat sources and ensure that the air vents are not
blocked when the product is in use.
6. DO NOT attempt to open or access the electrical components of the lamp. There are NO user
serviceable parts.
Day-Light Lamp (Model DL93011)
User Guide
SAVE THESE INSTRUCTIONS
The Day-Light is intended for household use only.
Disclaimer
The Day-Light is an innovative light supply
system and is not a listed medical device in
the USA.
LAMP HEAD
THERMAL VENTS
ANGLE ADJUSTMENT BUTTON
LIGHT SETTING & ON/OFF SWITCH
ARM ASSEMBLY
HEIGHT ADJUSTMENT BUTTON
COMPONENT POWER CORD
WEIGHTED BASE
Your Day-Light includes the following components:
• Lamp Head
• Adjustable Height Arm Assembly
• Weighted Lamp Base
• Component power cord
Day-Light User Guide
Day-Light Benets
The Day-Light brings the light of a
springtime morning into your home or
oce. Use your Day-Light to help relieve
the Winter Blues.
Daily use during the fall, winter and early
spring to help keep your mood and
energy level up, while pleasantly
brightening your day.
DL93011 SPECIFICATIONS
Safety: UL & C-UL Listed
Electrical: 120 VAC, 60Hz, 1.5A
Enclosure Size: 15.75” x 13” x 3.1” / 40 cm x 33 cm x 8 cm
Product Height: Max - 28.75”/ 73 cm - Min - 25” / 63.5 cm
Product Weight: 9.35 lbs / 4.24 kg
Light Source: 192 LED bulbs, UV Free, 4,000 Kelvin
Light Settings: 1) 10,000 LUX at 12”
2) 5,000 LUX at 12”
Warranty: Five-year limited
• #2 Philips Screwdriver
• 1 Philips Screw
• User Guide
2
Thank you for purchasing the Day-Light!
This bright light system was designed following the highest quality and safety standards.
For details on correct assembly and proper use of your Day-Light, please read this manual in
its entirety. Additional product information may found at www.carex.com.
3
www.carex.com
Before Using your Day-Light
Task light, reading lamp, or simply for glare-free ambient
light, your Day-Light can be used for much more than
light therapy.
1. Check contents to ensure all parts are enclosed and
in good condition.
2. Review this guide in its entirety.
3. Assemble the lamp and test the light tubes.
Complete your Warranty Registration online at
www.carex.com to ensure you are registered. Contact
your dealer if any product parts are missing or damaged.
Assembling the Day-Light
1. Attach the Weighted Lamp Base (1a - 1e) to the
Adjustable Height Arm using the screw and
screwdriver.
2. Lay the Lamp Head with the lens down on a solid non-
skid surface that will not damage the lens.
3. Slide the assembled Arm and Base (3a) into the Lamp
Head.
WARNING: The locking tab (3b) must be fully engaged
as shown to prevent the Arm and Base from detaching
from the Lamp Head and causing possible injury.
4. Fully insert the component plug (4a) and secure the
cord using the 3 clips on the back of the Arm. Plug
into a standard 120 VAC grounded outlet.
1a
FRONT
1c
1e
3a
3b
4a
Day-Light User Guide
1b
1d
Adjusting the Light Mode
High Intensity Setting - Therapy Mode
Slide the switch “UP” and the Day-Light emits 10,000
LUX of light at 12" -14” from the lamp. Do not use for
more than 60 minutes per session in Therapy mode.
Low Intensity Setting – Task/Ambient Mode
Slide the switch “DOWN” and 5,000 LUX will be emitted
at 12" - 14” from the lamp.
NOTE: After switching the Day-Light on, it takes about 30
seconds before reaching full intensity.
Adjusting Light Angle and Height
For optimum light therapy , adjust the lamp so that:
• Lamp head is angled at about 15° from vertical;
• Eyes face the approximate center of the lamp.
Angle of the Light
To set the angle of the lamp at about press the silver
button at the top of the Arm, while supporting the Lamp
Head. Release the button at the desired angle.
Height of the Light
Press the lower silver button, while supporting the Lamp
Head. Lift or lower the Lamp Head to the desired height
and release the button.
NOTE: Face toward the Day-Light with eyes open during
therapy - it is not necessary nor recommended to look
directly into the light.
Eyes should be
positioned approximately
at the center of the lamp 15⁰
3b
Day-Light Lamp (Model DL93011)
User Guide
The Winter Blues
Timing and Duration of Session
For best results use your Day-Light soon after
waking, preferably before 9 a.m. Begin with a 30
minute session and read, eat breakfast, etc. during
therapy.
Benets usually take a few days to appear. Since
each persons response varies, 30 minutes may not
produce the desired level of therapeutic response
or may cause unwanted side eects. Studies have
shown that up to 85% of those who try bright light
therapy have a clinical response.
Based on your response, tailor the session time, up
or down, in ve minute increments to nd the
optimal session length. We recommend that your
don’t use therapy mode for more than 60 minutes
per session.
You may also add a short session (15-20 min.) later
in the day, if experiencing a slump in energy.
However, using the Day-Light for therapy after 8
p.m. is not recommended as it may delay your
onset of sleep.
Adjusting to Light Intensity
Some users prefer to adjust to the brightness
before therapy sessions. Turn the lamp on just
before sitting in front of the lamp, so your eyes can
adjust to the bright light.
Daily Use
If you miss a session(s) or discontinue use of the
Day-Light, your body may return to its usual
wintertime doldrums. Benets should reappear a
few days after resuming use.
Increasing evidence demonstrates that using bright
light therapy lamps may also help alleviate jet lag,
shift work adjustment, improve sleeping patterns
and ease low energy.
Waking Up to the Day-Light
You can also wake up to the Day-Light by using a
properly rated lighting timer.
Symptoms of Overuse
There are rarely negative side eects of using light
therapy, but it is possible to overuse the Day-Light.
If you experience increased irritability, excessive
energy, and/or any discomfort during or after use,
decrease the session length or move the light
further away from you.
Helpful Resource
For a personalized prole of your Day-Light needs,
we recommend completing the free online user
assessments found at www.cet.org.
Carex Health Brands Canada
111 Morris Drive, Unit 11
Dartmouth, NS, B3B 1M2
1-800-387-0896
Carex Health Brands (USA)
921 E. Amidon Street
Sioux Falls, SD, 57104
1-800-526-8051
4

This manual suits for next models

3

Popular Home Lighting manuals by other brands

LUCCI FORREST installation instructions

LUCCI

LUCCI FORREST installation instructions

Safavieh Lighting LIT4377A quick start guide

Safavieh Lighting

Safavieh Lighting LIT4377A quick start guide

LUCCI JAXON installation instructions

LUCCI

LUCCI JAXON installation instructions

URBAN OUTFITTERS MABELLE Assembly instructions

URBAN OUTFITTERS

URBAN OUTFITTERS MABELLE Assembly instructions

Dale Tiffany TT13061 Assembly instructions

Dale Tiffany

Dale Tiffany TT13061 Assembly instructions

BALTENSWEILER TOPOLED T operating instructions

BALTENSWEILER

BALTENSWEILER TOPOLED T operating instructions

Safavieh Lighting BIJOU TBL4267A manual

Safavieh Lighting

Safavieh Lighting BIJOU TBL4267A manual

Orion Stl 12-1189/1 Mounting and safety instructions

Orion

Orion Stl 12-1189/1 Mounting and safety instructions

Contardi ONGO XL Instructions for installation, use and maintenance

Contardi

Contardi ONGO XL Instructions for installation, use and maintenance

Eurolux T20B Installation

Eurolux

Eurolux T20B Installation

JONATHAN Y JYL4026 manual

JONATHAN Y

JONATHAN Y JYL4026 manual

Adesso 5121-22 Assembly instruction

Adesso

Adesso 5121-22 Assembly instruction

Zafferano Poldina Pro XXL Instructions for use

Zafferano

Zafferano Poldina Pro XXL Instructions for use

FLOS KELVIN EDGE manual

FLOS

FLOS KELVIN EDGE manual

Safavieh Lighting TBL4176A quick start guide

Safavieh Lighting

Safavieh Lighting TBL4176A quick start guide

SLV 155780 85 Series instruction manual

SLV

SLV 155780 85 Series instruction manual

Philips 69068-87-16 Specifications

Philips

Philips 69068-87-16 Specifications

JONATHAN Y Modernist JYL3542A manual

JONATHAN Y

JONATHAN Y Modernist JYL3542A manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.