Product Overview
The ChamSys 10Scene Wall Mount can be used in conjunction with the QuickQ
Rack or SnakeSys Gateway to allow triggering of 10 Scene’s via its simple front
panel interface.
In it’s out of box configuration the 10Scene wall mount will toggle on/off the 10
Scenes or Executes from the Execute Window of its connected device. Is it
possible in software to change the default configuration to allow the 10Scene to
toggle on/off the 10 playbacks or QuickQ or MagicQ.
When used with a QuickQ Rack the 10Scene Wall Mount buttons duplicate the
functionality of the 10Scene buttons on the front panel of the QuickQ Rack
allowing for remote activation away from the Rack.
Installation
The 10Scene is available as the U.S. fit version (300-054) or EU fit version (300-
055) and fits into a standard U.S. Single Gang or EU Single Gang electrical back
box respectively. 10Scene uses its own 10Scene protocol for communication
between wall mounts and the controller. The recommended installation cable to
be used is standard Cat5e or Cat6 networking cable, the unit is not supplied with
any cable. 10Scene wall mounts are powered over the 10Scene protocol, no
external power supply is required.
System Configuration Options
10Scene wall mounts can be daisy chained together up to 10 per cable run.
QuickQ Rack has 4 10Scene ports, allowing a total of up to 40 10Scene wall
mounts to be connected to the rack. SnakeSys Gateway interfaces have 2 10Scene
ports, allowing up to 20 10Scene wall mounts to be connected to them.
10Scene Wall Mount’s
10Scene Wall Mount’s
QuickQ Rack
Cat5 Cable
Cat5 Cable
DMX to Fixtures

Connections
10Scene wall plates feature a 7 pin push lock cable connector which is wired
using the below table. 10Scene Wall mounts should be wired before connecting
to QuickQ Rack/Gateway Interface.
Pin
Name
Description
Recommended wiring
1
POWER +
Positive power in/out
CAT5e Orange pair IN (twisted together
2
POWER +
Positive power in/out
CAT5e Orange pair OUT (twisted together)
3
10Scene H
10Scene signal High in/out
CAT5e Blue/white wire IN/OUT
4
10Scene L
10Scene signal Low in/out
CAT5e Blue wire IN/OUT
5
10Scene 0V
10Scene 0V (NOT USED)
NOT USED
6
POWER -
Negative power in/out
CAT5e Brown pair IN (twisted together)
7
POWER-
Negative power in/out
CAT5e Brown pair OUT (twisted together)
When looking at the rear of the 10Scene Pin 7 is at the
top and Pin 1 at the bottom.
Pin 7
Pin 1
If daisy chaining, twist 10Scene High IN and the OUT wires together and connect to Pin 3,
and twist 10Scene Low IN and the OUT wires together and connect to Pin 4.

QuickQ Rack/Gateway 10Scene Wiring
The 10Scene connector is common to the QuickQ Rack and the Gateway, is a 5-
way terminal connector, with Pin 1 on the left, shown below.
Pin
Name
Description
Recommended wiring
1
POWER +
Positive power output to 10Scene
Wall plates
CAT5e Orange pair (twisted
together)
2
TRIG IN
Trigger input
5V logic or close contact to POWER -
Not used for 10Scene
3
10Scene H
10Scene signal High
CAT5e Blue/white wire
4
10Scene L
10Scene signal Low
CAT5e Blue wire
5
POWER -
Negative power output to 10Scene
Wall plates
CAT5e Brown pair (twisted
together)
Pin 1
Pin 5
When 10Scene Wall Mounts are first connected to QuickQ Rack or Gateway the front
panel LEDs of each 10Scene will flash briefly indicating the unit is powered and
connected.

10Scene Controls
The front panel interface contains 10 10Scene buttons, these
have dual colour LEDs used to indicate when a Scene has been
stored to a button and when a Scene is active.
When a button LED is Blue this indicates a Scene has been
stored, but is not active, when in Red this indicates the Scene is
active.
Buttons can be labelled using the provided paper legends with
the 10Scene Wall Mounts.
10Scene Programming
10Scene Wall mounts do not hold any programming themselves; they are a remote
trigger for QuickQ Racks or ChamSys systems using the Gateway interface.
For Information on Programming the QuickQ Rack please refer to the QuickQ Manual.

FCC Part 15 Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference; and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause interference with radio and
television reception. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Use the cables marked with VW-1 for interconnecting, for US and Canada,
the wires shall be additional marked CL2. 2.
The product shall be supplied by a PS2 limited or LPS source
You may also consult your local ChamSys Ltd dealer or an experienced radio/TV
technician for assistance.
NOTICE: The FCC regulations provide that any changes or modifications not expressly
approved by ChamSys Ltd could void the user’s authority to operate the equipment.

Disposal and Recycling of unwanted consoles
Please be aware that ChamSys products must be disposed of in accordance with the
WEEE disposal and recycling regulations
(http://ec.europa.eu/environment/waste/weee/index_en.htm).
ChamSys products must not be disposed of through normal household waste.
For non-UK customers please contact your local distributor.
For UK customers, please contact us on +44 (0)23 8023 8666, or email
support@chamsys.co.uk.
WEEE Producer registration number WEE/FF5605UX.
10Scene Warranty
10Scene Wall Mounts come with a two-year parts and labour warranty which covers the
device for component/material failure. This warranty does not cover physical damage
caused by damage in transit or damage to components caused by factors such as liquid
damage/spills onto the console.
For Warranty claims please contact the dealer you purchased the console from. If you
are based outside of the UK please contact your local dealer. Your local dealer can be
located here: www.chamsys.co.uk/contact
This manual suits for next models
1
Table of contents
Popular Rack & Stand manuals by other brands

delight
delight 39691 Installation

ERGO-INNOVATE
ERGO-INNOVATE EI6152 instruction manual

Workrite Ergonomics
Workrite Ergonomics CONF-2SDS-WOPB-S Assembly/installation instructions

SMS
SMS Icon WL 3D Installation and adjustment manual

BluDot
BluDot 2D 3D Coat Rack Assembly notes

Thule
Thule 300R quick start guide