PR-0490C 2022/04 Printing We reserve the right to change the specification without prior notice.
PSV-15 Series
➀
➁
➂
➃
➅
➆
➄
(Vacuum)
TYPE
Set pressure range
Withstand pressure
Fluid
Power supply voltage
Response time
Repeatability
Current consumption
Temperature characteristic
Lead wire
Weight
Environment
Enclosure
Ambient temp. range
Ambient humidity range
Withstand voltage
Insulation resistance
Vibration
Shock
-101 ~ 0 kPa
300 kPa
5ms or less
±1% F.S.
IP 40
Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute,
two hours each direction of X, Y and Z
50MΩ (at 500V DC, between case and lead wire)
Ø4 Oil-resistance cable (PVC) - 24 AWG (0.22mm2) - 3 cores
Approx. 50g (with 1 meter lead wire)
980m/s2 (100G), 3 times each in direction of X, Y and Z
1000V AC in 1-min (between case and lead wire)
±3% F.S. of detected pressure (25°C) at temp. Range of 0~50 °C
Operation/Storage : 35 ~ 85% RH ( No condensation)
Operation : 0 ~ 50°C, Storage : -20 ~ 60°C ( No condensation or freezing)
1NPN or 1PNP output : 21mA max., 2 NPN output : 35mAmax.
12 to 24V DC ±10%, Ripple (P-P) 10% or less
Filtered air, Non-corrosive/Non-flammable gas
PSV-15
D. DIMENSIONS
E. HOW TO SET PRESSURE
Do not use corrosive or flammable gas or liquid with this product.
Please use within the operating pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage
to the pressure sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can cause
malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and/or cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure switch should avoid power source line and high voltage line. If use in the same circuit, noise may cause malfunction.
For your safety, please read the following before using.
A. SPECIFICATIONS
B. CIRCUIT WIRING DIAGRAM
C. ORDERING INFORMATION
Output method
Hysteresis
Setting points
Operation indicating Lamp
1~10% of setting pressure (Adjustable)
Red LED turn on
1 Point 2 Points
3% F.S.or less (Fixed)
Out 1=Red; Out 2=Green
CHARACTERISTICS
CONNECT DIAGRAM
NPN open collector 30V 80mA PNP open collector 80mA NPN open collector 30V 80mA
Switch
main
circuit
Switch
main
circuit
Switch
main
circuit
Red
Brown
Black Load
Blue
DC(+)
DC(-)
OUT DC 12~24V
30V,80mA Red
Brown
Blue
Black
Brown
Blue
Black
White
DC(+)
DC(-)
Load
OUT
80mA
Load
Load
OUT1
OUT2
DC 12~24V
Red
Green
DC(+)
30V,80mA
30V,80mA
DC(-)
DC 12~24V
PSV-15-01 PSV-15-02 PSV-15-03
MODEL
Pressure Range
V:Vacuum (-101 ~ 0 kPa)
Output Specifications
01:NPN output
02:PNP output
03:2 NPN output
Cable Length/Connector
1 :With 1 meter cable
C:With M8 4Pin male connector
PSV -15-01-C
31
42
(1) Brown (+)
(2) White (OUT2)
(3) Blue (-)
(4) Black (OUT1)
Indicator
15.1
23
37.3
300
L : 01 : 1000mm
03 : 3000mm
L
QD PINOUT
Unit:mm
Remove dust cover to make any adjustments. Replace dust cover when finished to prevent foreign object from entering.
Pressure setting trimmer (SET) is for setting the output (ON) pressure. Rotate SET trimmer counter-clockwise to
increase (Pressure or vacuum) the ON point. Rotate clockwise will decrease the setting pressure.
Hysteresis setting trimmer (HYS) is for changing the hysteresis. Rotate trimmer counter-clockwise to increase the range
1~10%.
Use appropriate size screwdriver for the setting trimmers. Gently turn the screwdriver to make adjustments. Do not force
the trimmer when it comes to a stop to prevent damage to the setting trimmer.
Remove dust cover to make any adjustments. Replace dust cover when finished to prevent foreign object from entering.
Pressure setting trimmer (SET 1, SET 2) is for setting the output (ON) pressure. Rotate SET trimmer counter-clockwise
to increase (Pressure or vacuum) the ON point. Rotate clockwise will decrease the setting pressure.
Hysteresis for models with two outputs is 3% fixed.
PSV-15-01,02
PSV-15-01,02 PSV-15-03
PSV-15-03
Pressure setting trimmer 1
Pressure setting trimmer 2
Dust cover
Output Indicators
Out 1:Red LED
Out 2:Green LED SET1SET2
SET 2
SET 1
Pressure setting trimmer
Output indicator (Red LED)
Hysteresis setting trimmer
HYS Dust cover
SET
HYS
SET
PAP
22