Chroma A190201 User manual

3-Way Scanning Box
A190201/A190202
User’s Manual


3-Way Scanning Box
A190201/A190202
User’s Manual
Version 1.0
June 2013

Legal Notices
The information in this document is subject to change without notice.
Chroma ATE INC. makes no warranty of any kind with regard to this manual, including, but not
limited to, the implied warranties of merchantability and fitness for a particular purpose.
Chroma ATE INC. shall not be held liable for errors contained herein or direct, indirect, special,
incidental or consequential damages in connection with the furnishing, performance, or use of
this material.
CHROMA ATE INC.
66 Hwaya 1st Rd., Kueishan Hwaya Technology Park, Taoyuan County 33383, Taiwan
Copyright Notices. Copyright 2013 Chroma ATE INC., all rights reserved. Reproduction,
adaptation, or translation of this document without prior written permission is prohibited,
except as allowed under the copyright laws.
ii

Warranty
All of Chroma’s instruments are warranted against defects in material and workmanship for a
period of one year from date of shipment. Chroma agrees to repair or replace any assembly
or component found to be defective, under normal use during this period. Chroma’s obligation
under this warranty is limited solely to repairing any such instrument, which in Chroma’s sole
opinion proves to be defective within the scope of the warranty when returned to the factory or
to an authorized service center. Purchaser is responsible for the shipping and cost of the
service item to Chroma factory or service center. Shipment should not be made without prior
authorization by Chroma.
This warranty does not apply to any products repaired or altered by persons not authorized by
Chroma, or not in accordance with instructions furnished by Chroma. If the instrument is
defective as a result of misuse, improper repair, or abnormal conditions or operations, repairs
will be billed at cost.
Chroma assumes no responsibility for its product being used in a hazardous or dangerous
manner either alone or in conjunction with other equipment. High voltage used in some
instruments may be dangerous if misused. Special disclaimers apply to these instruments.
Chroma assumes no liability for secondary charges or consequential damages and in any
event, Chroma’s liability for breach of warranty under any contract or otherwise, shall not
exceed the purchase price of the specific instrument shipped and against which a claim is
made.
Any recommendations made by Chroma regarding the use of its products are based upon
tests believed to be reliable; Chroma makes no warranty of the results to be obtained. This
warranty is in lieu of all other warranties, expressed or implied, and no representative or
person is authorized to represent or assume for Chroma any liability in connection with the
sale of our products other than set forth herein.
CHROMA ATE INC.
66 Hwaya 1st Rd., Kueishan Hwaya Technology Park,
Taoyuan County 33383, Taiwan
Tel: 886-3-327-9999
Fax: 886-3-327-2886
e-mail: [email protected]
http://www.chromaate.com
iii

Material Contents Declaration
The recycling label shown on the product indicates the Hazardous Substances contained in
the product as the table listed below.
: See <Table 1>.
: See <Table 2>.
<Table 1>
Hazardous Substances
Lead Mercury Cadmium Hexavalent
Chromium Polybrominated
Biphenyls Polybromodiphenyl
Ethers
Part Name
Pb Hg Cd Cr6+ PBB PBDE
PCBA O O O O O O
CHASSIS O O O O O O
ACCESSORY O O O O O O
PACKAGE O O O O O O
“O” indicates that the level of the specified chemical substance is less than the threshold level
specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
“°” indicates that the level of the specified chemical substance exceeds the threshold level
specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
Disposal
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging your health and
well-being. When replacing old appliances with new one, the retailer is legally obligated to
take back your old appliances for disposal at least for free of charge.
iv

<Table 2>
Hazardous Substances
Lead Mercury Cadmium Hexavalent
Chromium Polybrominated
Biphenyls Polybromodiphenyl
Ethers
Part Name
Pb Hg Cd Cr6+ PBB PBDE
PCBA °O O O O O
CHASSIS °O O O O O
ACCESSORY °O O O O O
PACKAGE O O O O O O
“O” indicates that the level of the specified chemical substance is less than the threshold level
specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
“°” indicates that the level of the specified chemical substance exceeds the threshold level
specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
1. Chroma is not fully transitioned to lead-free solder assembly at this moment; however,
most of the components used are RoHS compliant.
2. The environment-friendly usage period of the product is assumed under the operating
environment specified in each product’s specification.
Disposal
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging your health and
well-being. When replacing old appliances with new one, the retailer is legally obligated to
take back your old appliances for disposal at least for free of charge.
v

Safety Summary
The following general safety precautions must be observed during all phases of operation,
service, and repair of this instrument. Failure to comply with these precautions or specific
WARNINGS given elsewhere in this manual will violate safety standards of design,
manufacture, and intended use of the instrument. Chroma assumes no liability for the
customer’s failure to comply with these requirements.
BEFORE APPLYING POWER
Verify that the power is set to match the rated input of this power supply.
PROTECTIVE GROUNDING
Make sure to connect the protective grounding to prevent an electric
shock before turning on the power.
NECESSITY OF PROTECTIVE GROUNDING
Never cut off the internal or external protective grounding wire, or
disconnect the wiring of protective grounding terminal. Doing so will
cause a potential shock hazard that may bring injury to a person.
FUSES
Only fuses with the required rated current, voltage, and specified type
(normal blow, time delay, etc.) should be used. Do not use repaired
fuses or short-circuited fuse holders. To do so could cause a shock or
fire hazard.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or
fumes. The instrument should be used in an environment of good
ventilation.
DO NOT REMOVE THE COVER OF THE INSTRUMENT
Operating personnel must not remove the cover of the instrument.
Component replacement and internal adjustment can be done only by
qualified service personnel.
WARNING 1. Lethal voltage. The output may up to 6000V voltage.
2. Touching the output terminal on the front or rear panel or connecting
circuit to output when the power is on may result in death.
vi

Safety Symbols
DANGER – High voltage.
Explanation: To avoid injury, death of personnel, or damage to
the instrument, the operator must refer to an explanation in the
instruction manual.
High temperature: This symbol indicates the temperature is now
higher than the acceptable range of human. Do not touch it to
avoid any personal injury.
Protective grounding terminal: To protect against electrical
shock in case of a fault. This symbol indicates that the terminal
must be connected to ground before operation of equipment.
WARNING
The WARNING sign denotes a hazard. It calls attention to a
procedure, practice, or the like, which, if not correctly performed or
adhered to, could result in personal injury. Do not proceed
beyond a WARNING sign until the indicated conditions are fully
understood and met.
CAUTION The CAUTION sign denotes a hazard. It may result in personal
injury or death if not noticed timely. It calls attention to
procedures, practices and conditions.
The Notice sign denotes important information in procedures,
applications or the areas that require special attention. Be sure
to read it carefully.
vii

Unpacking for Check & Inspection
Before shipment this instrument was inspected and found to be free of mechanical and
electrical defects. As soon as the instrument is unpacked, inspect for any damage that may
have occurred in transit. Save all packing materials in case the instrument has to be
returned. If damage is found, please file claim with carrier immediately. Do not return the
instrument to Chroma without prior approval.
A190201/A190202 Standard Package & Accessories
Standard Equipment
A190201 or A190202 x 1
User’s Manual CD x 1
A190201 TA Board
1 pc.
High voltage hazard label x 1
Quick Start Guide x 1
Standard Accessories (Cables)
Power Cord
US Standard
90 Degree Elbow
1 pc
Power Adapter
3PIN to 2PIN
Converter 1 pc
High Voltage
Head + High
Voltage Cable
A190201: 30 pcs.
A190202: 12 pcs.
1.6A fuse
2 pcs.
Cable
BNC-BNC
A190201: 10 pcs.
A190202: 4 pcs.
High Voltage
Head*2+ High
Voltage Cable
A190201: 10 pcs.
A190202: 4 pcs.
Control Cable
1 pc.
TA Board
Note When additional items are required, contact Chroma and provide item’s
description.
viii

Hazard Operations
This scanning box is able to output high voltage via remote control. For safety precaution, it
is necessary to follow the guidelines listed below when performing the control remotely.
yDo not output any unexpected high voltage as it may cause danger.
yOperators and other personnel are not allowed to touch the UUT, test cable and the
probe terminal when there is high voltage output.
yThe remote control is usually conducted using the high voltage bar. However, it can
also use other circuit for control without using the high voltage bar. As the bar is the
switch for high voltage output, it is necessary to keep the connected control cable away
from the high voltage bar and the test cable to avoid causing any danger.
WARNING Do not tie up the high voltage cable with RS232, Handler and GPIB
control cables or other low voltage side wires. If so, it could cause the
product or PC to be down or damaged.
ix

Storage, Freight & Maintenance
Storage
When not in use, please pack the device properly and store in a suitable environment.
Freight
Please pack the device carefully before moving it. If any of the original packing material is
missing, please use suitable alternative material and mark it “fragile” and “keep away from
water” to avoid damaging the product.
This product is a piece of precision test equipment, so please do not drop or hit it.
Maintenance
In case of any malfunction or abnormality, please refer to the manual, or contact our local
distributor for prompt service. Do not touch any parts inside the instrument to avoid any
danger to yourself or damage to the product.
x

xi
Revision History
The following lists the additions, deletions and modifications in this manual at each revision.
Date Version Revised Sections
Jun. 2013 1.0 Complete this manual.


3-Way Scanning Box A190201/A190202 User’s Manual
xiii
Table of Contents
1. Preface..........................................................................................................................1-1
1.1 Overview..............................................................................................................1-1
1.2 Feature ................................................................................................................1-1
2. Specification................................................................................................................2-1
3. Precautions before Use ..............................................................................................3-1
4. Operating......................................................................................................................4-1
4.1 Connecting Rear Panel........................................................................................4-1
4.2 Output Terminals on the Front Panel ...................................................................4-2
4.3 Using the 19020/19020-4 to Control A190201/ A190202....................................4-3
4.4 Setting Output Channel Parameter......................................................................4-4


Preface
1-1
1. Preface
1.1 Overview
The scan input of this 3-Way Scanning Box connects to the Multi-Channel Hipot Tester of
Chroma Model 19020 or 19020-4 (AC 5kV/DC 6kV) to perform multi-channel, multi-dot high
voltage scanning test for UUT’’s primary, secondary or core testing.
1.2 Feature
Fixed test mode
The scanning box can work with the Chroma Model 19020/19020-4 to perform the built-in
scanning test. It can test 10 UUTs (A190201) or 4 UUTs (A190202) simultaneously for
Primary, Secondary or Core scanning tests.


Specification
2-1
2. Specification
Scanner HV INPUT: AC 5kV/ DC 6kV maximum
HV OUTPUT: P/S/C ON/OFF
INTERFACE: Link to 19020/19020-4 scan interface
CAPACITY: Maximum 1 Box
Indicator UNDER TEST LED
P: Primary, S: Secondary, C: Core
Line Input 90Vac ~ 250Vac, 50 or 60 Hz
80Watt Rated Power
Operable Range 0°C to 40°C, Maximum relative humidity 80% for
temperature up to 31°C (88°F).Decreasing linearly to 50%
relative humidity at 40°C (104°F)
Storage Range -10 to 60°C (14 to 140°F), ≤80% RH.
Dimension(WxHxD) 430 x 100 x 600 mm / 16.929 x 3.937 x 23.62 in.
Weight A190201: < 20 kg / < 44lb.
A190202: <14.8kg / <33lb

This manual suits for next models
1
Table of contents
Popular Scanner manuals by other brands

Metrologic
Metrologic MS9590i VoyagerGS Series Installation and user guide

Socket
Socket CF RFID Reader-Scan Card Series 6 user guide

Fujitsu
Fujitsu ScanSnap S1300i Basic operation guide

Epson
Epson Perfection 3490 Photo Start here

C-Pen
C-Pen Connect BT10 quick start guide

Panasonic
Panasonic KV-S1057C operating manual