19ENGLISH |
GENERAL INFORMATION
Original instructions for use.
This manual must always accompany this device and it must
be kept in an accessible place so that the users and those re-
sponsible for its maintenance can consult it.
It is recommended that the installer/user should carefully
read the specications and the information contained in the
present manual before using the product in order toavoid
damage, the improper use of the equipment or the forfeiture
of the guarantee.
This product must not be used bychildren or bypersons with
a reduced physical, sensory or mental capacity,or bythose
who lack experience or knowledge, if they havenot received
the necessary supervision and instruction. Caremust be tak-
en toavoid children playing with the device.
The manufacturer does not accept any responsibility in
the event of accidents or damage caused bynegligence or
non-compliance with the instructions contained in this bro-
chure or in conditions which dier from those set out below.
Also it does not accept any responsibility for damage caused
bythe improper use of the pump.
Donot place any weights or other boxes on top of the pack-
age.
SAFETY REGULATIONS
In this manual symbols with the following meaning have
been used.
This symbol warns that non-compliance with
the specications brings with it the risk of
electric shocks.
This symbol warns that non-compliance with
the specications brings with it the risk of
harm topersons or damage toproperty.
BEFORE INSTALLING AND USING THE PRODUCT
:
• carefully read this manual in all its parts;
• check that the data on the registration plateare those
wanted and suitable for the device;
• installation and maintenance must be carried out byqual-
ied personnel responsible for establishing the electrical
connections in accordance with the local rules of installa-
tion;
• the manufacturer does not accept any responsibility for
damage caused bymaintenance or repairs carried out by
unqualied personnel and /or byspare parts which are not
original;
• the use of spare parts which are not original, tampering or
misuse will result in the forfeiture of the guarantee.
DURING THE INITIAL INSTALLATION AND IN
CASE OF MAINTENANCE MAKE SURE THAT:
• The power supply has been switched o.
• The power supply is provided with safeguards and in par-
ticular a highly sensitive circuit breaker (30 mA in class A)
in order toprotect from alternating, pulsating unipolar,
continuous and high frequency currents due tofaults. In
addition check that the earthing complies with the re-
quired local standards.
• Beforeremoving the lid of the inverter or starting proce-
dures on it the power supply must be disconnected before
waiting atleast ve minutes so that the capacitors have
the time tolose their charge through the incorporated dis-
charge resistors.
WARNING: when the DOMUS is out of ser-
vice (red LED ashing) it is still electrically
charged. Before any form of intervention on
the pump or on the inverter it is obligatoryto
disconnect the power supply tothe pump.
Emergency Stop
• Whilst the DOMUS is in operation it is possible tocarry out
an emergency stop bypressing the I/OON switch.
• In the applications with two units in parallel it is only the
MASTER inverter which blocks the system.
During both the rst installation and mainte-
nance ensure THERE IS NO POWER in the line.
During both the rst installation and mainte-
nance ensure the plant is UNPRESSURED.
DO NOT OPEN THE COVERS OF THE INVERTER
except the cover of the connectors.