12. Do not store or use the meter in areas exposed to direct sunlight, at high
temperature or with high relative humidity.
13. To avoid false readings, replace the batteries as soon as the Low Battery
indicator appears.
14. Before use, verify the meter operation by measuring a known voltage.
15. Never touch exposed wiring, connections or any live circuit while taking
any measurements.
16. Keep your body isolated from ground by using dry clothing, rubber shoes,
rubber mats or any approved insulating material.
SPECIFICATIONS
Product dimensions: (L x W x H) 195 x 95 x 52 mm
Weight (inc battery) 425 g
Test leads length (inc probes) 990 mm
Max voltage between input & earth 600V
Fuses F1 400mA/600V, F2 10A/600V
Power PP3 type 9V battery
Maximum display value 1999
Over-range indication “1”
Polarity display “-” for negative polarity
Detects and measures voltages DCV 200m/2/20/200 ± 0.5%, 600 ± 0.8%
ACV 2/20/200 ± 0.8%, 600 ±1.2%
Detects and measures resistance Ohm 200Ω± 0.8%,2k/20k/200k, 2M ±
8%, 20M ± 1%, 200M ± 6%
Detects and measures current DCA2m, 20m ± 8%, 200m± 1.5%, 10± 2%
ACA 20m ± 1%, 200m ± 1.8%, 10± 3%
Detects and measures frequency Hz 20k ± 2%
Detects and measures
capacitance
F 2n, 20n, 200n, 2µ ± 4%,100µ ± 6%
Detects and measures temperature C° -20 to 0 ± 5%, 1-400 ± 2%, 401-1000 ±
2%
Operating temperature 0-40°C
Storage temperature 0°C to 60°C
Auto power-off time 20 min