cliMATE MCM230 User manual

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
PRODUCT MANUAL
MCM230
PORTABLE AIR CONDITIONER

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 2
WARNINGS
These instructions should be read by:
The specifying engineer.
The installation engineer.
The user.
The service engineer.
• Failure to follow these instructions may result in risk of personal injury or damage to the
equipment.
• Damage due to a failure to follow these instructions will invalidate the warranty.
• The appliance must be serviced by qualied engineers in compliance with local regulations.
• The appliance must be switched o and disconnected from the power supply before any work
is carried out.
• There are no user controls inside the appliance casing.
• Do not place anything on top of the appliance.
• An air gap of at least 300mm should be allowed at the front and rear of the unit to ensure a
clear airow.
• Do not disconnect the appliance from the supply under load.
• For internal use only. Do not use out of doors.
• Extension cables should be correctly rated for the load,fully unwound and never run through
water or over sharp edges.
• Always transport and store in an upright position.
• Maximum operating temperature 35°C.
• Minimum operating temperature 21°C.
SPECIFICATIONS:
The MCM230 is a Mono-block portable air conditioning unit. It is connected to a 13 Amp. 230Vac. 50Hz power supply
and comes tted with a fused uk moulded plug.
It is recommended that the supply to the machine should be protected by a 30mA RCD

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 3
SET UP AND OPERATION:
• The unit is designed to operate between 21°C and 35°C. Operation outside of these temperatures could cause
compressor failure and will invalidate the warranty. If the temperature in the room is above 35 C it is recommend-
ed that all the doors and windows are opened and the unit run on Fan only to reduce the temperature.
• Site the unit on a rm level surface and apply the castor brakes. Do not operate the machine without engaging
the castor brakes.
• Attach the 400mm exhaust duct and route to a suitable discharge point. Keep the duct as short and straight as
possible. Do not operate the unit if the hose is kinked or puntured. Do not exceed the supplied length of exhaust
duct.
• Should air need to directed to a particular area t the air discharge hoses to the front outlets and extend to the
desired discharge points. Do not exceed 1.25M per hose.
• Check that the water drain tank is correctly located in it's housing and the exible drain hose is inserted into the
tank.
• Connect the unit to a 230Vac 50Hz power supply and check that the 'Power On' lamp is illuminated.
• Turn the 'Fan On' switch to 'I' to start the fans.
• Turn the 'Cooling On' switch to 'I' to start the compressor. It should be noted that the compressor will not start if
the fans are not running or the ambient temperature is below 21°C. The compressor is tted with a start delay
timer and will not run for 3 minutes from activation of the cooling switch. This device is designed to protect the
compressor from repeated start/stop cycles.
• Allow a minimum of 10 minutes for the unit to start cooling.
• During the cooling process the unit will produce condensate (water) which will drain into the water drain tank.
Once this tank lls to a set level it will switch the compressor and fans o and illuminate the 'Tank Full' lamp.
• Before removing the water drain tank, and to avoid any potentially damaging water spillage, switch the fans and
cooling o and allow 5 minutes for any accumulated moisture within the machine to drain into the tank.
• To empty the tank carefully remove it from the machine using the grab handle on the top by lifting and sliding it
forwards. Do not loosen or remove the large screw cap on the front of the tank. Once the tank is emptied replace
it in the housing ensuring it is correctly located and that the exible drain hose is inserted into the tank.
• The machine can now be restarted.
• Ensure the water drain tank is empty prior to transportation.
• Do not remove the water drain tank while the machine is operating.

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 4
OPERATION AND CONTROLS:
Discharge
hoses
Water drain
tank
Locking castors
Exhaust
discharge
Fans on
rocker
switch
Cooling on
rocker switch
Tank full
lamp
Power on
lamp
OPTIONAL THERMOSTAT:
The MCM230 may come with an optional thermostat. To achieve maximum cooling capacity rotate the thermostat
fully anti-clockwise.

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 5
MAINTENANCE:
1. Check and clean the evaporator and condenser heat exchanger coils. Build up of dust and dirt can severly eect
the performance of the machine. Remove the front and rear panels and clean with compressed air.
2. Periodically check the water tank drain mechanism is operating correctly and the drain hose is present and in
good condition.
3. Regularly inspect the mains cable and plug for signs of damage or wear. Do not operate the machine with a
damaged mains cable.
4. Check that the castors are running freely and that the breaking mechanisms are working correctly.
TROUBLESHOOTING GUIDE:
PROBLEM POSSIBLE CAUSE SOLUTION
Machine fails to operate Power Failure
Check power on lamp is illuminated.
Check unit is connected to the power supply.
Check plug fuse for failure and correct 13A
rating
Check Building circuit is not overloaded.
Poor cooling performance.
‘Tank Full’ lamp illuminated Empty water tank.
Cooling not selected Switch cooling on
If tted, Thermostat knob not turned fully anti-
clockwise
Turn knob fully anti-clockwise.
Allow 3 minutes for compressor to start and 10
minutes for cooling.
Coils dirty
Filters dirty. (where tted)
Exhaust hose too long or kinked.
Exhaust outlet restricted or blocked.
Clean coils. See Maintenance.
Clean lters. See Maintenance.
Ensure maximum duct length is not exceeded.
Ensure duct is run as straight as possible and is
venting correctly al it’s exit point.
Air inlet grills obstructed Remove obstruction.
Water leaking.
Clogged drain hose.
Water drain tank missing
Remove blockage.
Replace tank
Tank full and tank mechanism not working
correctly.
Check tank mechanism operates correctly.
Ensure ‘Tank Full’ lamp illuminates when
mechanism is actived.
Drain hose not correctly located in tank. Ensure drain hose is located inside the tank.
Compressor stops working. Input voltage too low.
Water drain tank full
Check line voltage.
Check water drain tank is not full
SHOULD YOU CONTINUE TO EXPERIENCE PROBLEMS PLEASE CONTACT THE SUPPLIER.

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 6
EXPLODED VIEW:
10
12
17
21
28
1
2
3
4
5
6
7
8
9
11
13
14
15
16
18
19
20
23
24
25
28
22
35
30
31
32
33
34
26
27
29

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 7
SPARE PARTS:
ITEM No PART No DESCRIPTION PRICE
1BW0201220 TOP REAR PANEL POA
2FA010124 CONDENSER FAN POA
3BW0201221 CENTRE PANEL POA
4BW0201222 REAR PANEL POA
5FR030211 CONDENSER COIL POA
6FR010122 COMPRESSOR POA
7EL020108 MAINS CABLE POA
8ME040305 TRUNK HANDLE POA
9BW0201223 RIGHT SIDE PANEL POA
10 ME010211 100mm FIXED CASTOR POA
11 BW0201224 BASE PANEL POA
12 ME010212 100mm SWIVEL CASTOR POA
13 BW0201225 LOWER FRONT PANEL POA
14 ME040137 CONDENSATE TANK POA
15 BW0201226 EVAPORATOR PANEL POA
16 FR030111 EVAPORATOR COIL POA
17 EL030145 SPEED CONTROLLER POA
18 BW0201230 GALVANISED DRIPTRAY POA
19 BW0201229 LEFT SIDE PANEL POA
20 FA010317 EVAPORATOR FAN POA
21 BW030201 1500 DUCT C/W PLASTIC COLLAR POA
22 ME040201 CABLE GLAND AND LOCKNUT POA
23 BW0201232 FRONT TOP PANEL POA
24 EL030111 55uf CAPACITOR POA
25 EL020423 MODULAR TERMINAL BLOCK POA
26 EL030704 INDICATOR LIGHT POA
27 EL030109 0/1 ROCKER SWITCH POA
28 EL020415 40A TERMINAL BLOCK POA
29 EL030101 MICROSWITCH POA
30 ME040526 SPRING POA
31 EL020423 MODULAR TERMINAL BLOCK POA
32 EL030403 DIGISTAT XR10 POA
33 BW0201233 ELECTRICS PLATE POA
34 EL030201 SLAVE RELAY POA
35 BW0201228 SWITCH PLATE POA
36 BW030110 EXHAUST DUCT. (NOT SHOWN) POA
37 BW030438 FASCIA LABEL (NOT SHOWN) POA
38 FR020101 3/8 COPPER PIPE (NOT SHOWN) POA
39 FR020301 20g FILTER DRIER (NOT SHOWN) POA
40 FR010302 3/8 INSULATION TUBE (NOT SHOWN) POA

PRODUCT MANUAL MCM230 PORTABLE AIR CONDITIONER
Page 8
Table of contents
Other cliMATE Air Conditioner manuals
Popular Air Conditioner manuals by other brands

York
York J ZJ Series instruction manual

Mitsubishi Electric
Mitsubishi Electric CITY MULTI CMY-Q100VBK installation manual

Toshiba
Toshiba RAS-M07SKV Series owner's manual

Airxcel
Airxcel 48000 Series Operation and maintenance instructions

Engineered Comfort
Engineered Comfort 35FH Series installation instructions

INVENTOR
INVENTOR PFI2VO-09 user manual