Primary Configuration Kit Capacity
4380 & 34380 11/1901-10146-00
6 FT - 10 FT ADJUSTABLE GARAGE ORGANIZER
INSTALLATION INSTRUCTIONS
What you will need:
Maximum Shelving Load*: 100 lbs/ft
Maximum 40 in. Hang Track Load*: 700 lbs
Maximum System Load*: 1,400 lbs
(See pages 6)
• Please read all instructions carefully.
• Familiarize yourself with all parts (see “PARTS INCLUDED WITH KIT”) and check quantities.
• Follow all safety precautions (see “SAFETY PRECAUTIONS”).
• Follow all manufacturer installation requirements in order to comply with the
advertised weight load specifications.
BEFORE BEGINNING
Primary Configuration
*Static Load Evenly Distributed. Must be installed per manufacturers
specifications or weight load capacity does not apply.
Whichever load reaches
capacity first:

2© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
PARTS INCLUDED WITH KIT
Hang Track
Standard
Standard Extender
Shelf Bracket
Hang Shelf
Hang Shelf
Screw
Toggle
Panhead Screw
Anchor
End Caps
40 in. (3)
48 in. (10)
(4)
(23)
48 in. (2)
72 in. (2)
3/ 16 in. (45)
3/ 16 in. (45)
#12 x 2 in. (45)
1/4 in. (45)
(48)
93583
93585
28192
93582
43717
43719
274
270
688
650
90813
A
B
C
D
E
F
AA
BB
CC
DD
EE
Name Size (Qty) Part Number
AAA
B BB
CCC
D DD
E
F
EE

3© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
FOLLOW INSTRUCTIONS CAREFULLY
Please do not return product to the retail store. For product assistance and warranty
information please call Consumer Affairs at 1-800-874-0008.
Manufacturer Warranty
Manufacturer will replace any missing or damaged part due to manufacturer defect for one
year after purchase. Please have proof of purchase for warranty claims.
• Unit MUST be installed as per the installation instructions begining on
page 7 to satisfy published weight load capacity.
• This unit contains small parts which could be a choking hazard for small
children. Children should be under adult supervision at all times or
serious injury could occur.
• Always unload unit prior to moving the unit. The weight of personal
belongings can cause the unit to become unstable and either tip or
collapse. Serious bodily injury and/or damage to personal belongings
may occur.
• Do not overload unit. If any shelf, top, or bottom of unit bows or bends,
it is overloaded. The shelf, top, or bottom could collapse and cause
serious bodily injury and/or damage to personal belongings.
• Do not drop items on shelves.
SAFETY PRECAUTIONS
WARNING
• Do not climb or step on the unit. The unit may become unstable and
either tip or collapse. Serious bodily injury and/or damage to personal
belongings may occur.
• Do not mount or attach anything to the sides, rear or front of the unit as
this can create a force which can cause the unit to tip. Serious bodily
injury and/or damage to personal belongings may occur.
• Follow proper safety procedures if using power tools and ladders.
• We recommend you protect your work surface during assembly to
prevent scratching or damage to table tops, wood floors, etc.
• We recommend you hand-tighten screws. Use care not to overtighten if
using power tools.

4© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
1MEASURE AND FIT (WIDTH)
This organizer is very versatile. Depending upon your area size, there are several options. Once you understand the basic concept of how the pieces work together, your design options are
numerous. However, it is important to understand what your final organizer will look like before proceeding.
Please study the diagrams on the next page featuring several closet design ideas. Locate the diagram which is CLOSEST to your actual area size. Then, choose the design option you prefer
for your closet. In some cases, Hang Track, shelf, and/or Standards are cut to fit. These pieces should be cut to fit, depending upon your area’s specific size.
Measure wall area width and height to determine if cutting of the Hang Track, shelving, or Standards will be required. In the case of a wall area which is smaller than 80 in., the Hang Track
and possibly the shelves will require cutting. In the case of a wall height which is shorter than 98 in., the Standards may require cutting.
PLEASE NOTE: Any alteration of components voids any advertised performance specifications listed in this manual.

5© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
CONFIGURATION EXAMPLES
10 ft.
40 in. 40 in. 40 in.
10 ft.
40 in. 40 in. 40 in.
10 ft.
40 in. 40 in. 40 in.
Configuration 3
Configuration 4
Configuration 5
A
CUT HANG TRACK, IF NECESSARY
CUTTING WILL ONLY BE REQUIRED FOR SPACES LESS THAN 80 IN. OR 120 IN. WIDE.
If your space is less than 80 in. or 120 in. wide, cutting Hang Track to fit space may be required.
See Hang Track Location Diagrams for guidelines depending on your closet width.
Advertised weight loads in this manual apply to ONLY Configuration 1 (the Primary Configuration) as installed per manufacturers specification and DO NOT APPLY to any other alternative configurations.
6.67 ft.
40 in. 40 in.
6.67 ft.
40 in. 40 in.
Configuration 1: Primary Configuration
Configuration 2

6© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
PARTS NEEDED FOR
PRIMARY CONFIGURATION
Ax2
x9
x4
x18
x2
x2
x48 * Installation hardware varies based on wall type
B
D
E
F
EE
C

7© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
SAFETY PRECAUTIONS
RECOMMENDED INSTALLATION
The following installation is required to satisfy the weight capacity rating indicated for this product. In order for the weight load specifications to be valid, you MUST install the components
in this organizer per the following installation instructions. Before moving on to the system installation instructions, please take the time to review the installation requirements below.
If you are unable to install per the primary configuration installation instructions, alternate installation methods are provided on page 6.
WARNING
A)
B)
C)
Locate studs:
Must hit studs in at least 5 holes.
Use the supplied toggle bolts on the holes indicated here, which are not in studs.
AA
AA AA AA AA
BB
BB BB BB BB
CC
CC CC CC CC
STUD STUD STUD STUDSTUD
TOGGLE TOGGLE TOGGLE TOGGLE TOGGLE

8© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
2MARK HANG TRACK LOCATION
98 in.
A) The Hang Track can be installed at any height, keeping in mind the overall height of your Standards once installed.
B) Measure Hang Track to desired height, use level to assure Hang Track is straight before marking holes and making a level line.
C) When track is at desired height and level, mark each screw hole on the wall using a pencil. Do this for all tracks, spacing according to the size of the space you’re installing in. It is
recomended to install one track before other(s), including drilling any necessary holes.
D) For Configurations 1 and 2, the minimum Hang Track installed height is 98 in.

9© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
3a FOR DRYWALL INSTALLATION
C) Insert a toggle bolt into the predrilled holes in the drywall. Be sure to install the toggle bolt assembly only in the holes where there are no studs.For any marks over a stud, use a
panhead screw directly. This will enhance the security of the Hang Track mounting.
IMPORTANT: SECURE HARDWARE THROUGH EACH HOLE!
* Tighten toggle bolt first, then stud screws
B) Insert the toggle bolts through the holes in the Hang Track where there will not
be studs, then thread the toggle anchor onto the bolt once it is through the track.
STUD = SCREW
DRYWALL = TOGGLE BOLT
TOP
BOTTOM
A
AA
BB
CC
DRILL 1/2 IN. HOLES.
FOR DRYWALL INSTALLATION
A) Locate each pencil mark and drill a 1/2 in. hole for any marks not over a stud. DRILL 1/2 IN. HOLES. NO DRILL FOR STUD MOUNTING.

10 © 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
3b FOR CONCRETE INSTALLATION
DD
B) Insert anchors into 1/4 in. predrilled holes and secure Hang Track with panhead screws.
IMPORTANT: SECURE HARDWARE THROUGH EACH HOLE!
FOR CONCRETE INSTALLATION
A) Locate each pencil mark and drill a 1/4 in. hole at least 2 in. deep using a masonry drill bit.
DRILL 1/4 IN. HOLES.
SCREWS AND ANCHORS ONLY
CC
DRILL 1/4 IN. HOLES.

11© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
4INSTALL STANDARDS ONTO HANG TRACK
Attach Standards to the Hang Track by nesting each Standard into the top groove as shown below. Measure from CENTER of one Standard to CENTER of next Standard. Space Standards NO
MORE than 16 in. apart and a MINIMUM of 2 in. in from end of Hang Track.
Adjust Standards evenly for your specific closet width.
REFERENCE FOR STANDARD POSITIONS
A
B
2 in.
16 in. 16 in. 9 in. 16 in. 9 in. 9 in.
9 in. 16 in.16 in.2 in. 2 in.
13 in. 16 in. 13 in. 13 in. 7 in. 16 in.14 in. 8 in.16 in.2 in. 2 in.
16 in. 4 in. 15 in. 15 in. 4 in. 12 in.16 in. 13 in.14 in.9 in. 2 in.
13 in. 14 in. 14 in. 14 in. 13 in.2 in. 2 in.
16 in. 16 in. 16 in. 16 in.7 in. 8 in.
16 in. 16 in. 9 in. 16 in. 9 in. 9 in.
9 in. 16 in.16 in.2 in. 2 in.
13 in. 16 in. 13 in. 13 in. 7 in. 16 in.14 in. 8 in.16 in.2 in. 2 in.
16 in. 4 in. 15 in. 15 in. 4 in. 12 in.16 in. 13 in.14 in.9 in. 2 in.
13 in. 14 in. 14 in. 14 in. 13 in.2 in. 2 in.
16 in. 16 in. 16 in. 16 in.7 in. 8 in.
16 in. 16 in. 9 in. 16 in. 9 in. 9 in.
9 in. 16 in.16 in.2 in. 2 in.
13 in. 16 in. 13 in. 13 in. 7 in. 16 in.14 in. 8 in.16 in.2 in. 2 in.
16 in. 4 in. 15 in. 15 in. 4 in. 12 in.16 in. 13 in.14 in.
9 in. 2 in.
13 in. 14 in. 14 in. 14 in. 13 in.2 in. 2 in.
16 in. 16 in. 16 in. 16 in.7 in. 8 in.
16 in. 16 in. 9 in. 16 in. 9 in. 9 in.
9 in. 16 in.16 in.2 in. 2 in.
13 in. 16 in. 13 in. 13 in. 7 in. 16 in.14 in. 8 in.16 in.2 in. 2 in.
16 in. 4 in. 15 in. 15 in. 4 in. 12 in.16 in. 13 in.14 in.9 in. 2 in.
13 in. 14 in. 14 in. 14 in. 13 in.2 in. 2 in.
16 in. 16 in. 16 in. 16 in.7 in. 8 in.
16 in. 16 in. 9 in. 16 in. 9 in. 9 in.
9 in. 16 in.16 in.2 in. 2 in.
13 in. 16 in. 13 in. 13 in. 7 in. 16 in.14 in. 8 in.16 in.2 in. 2 in.
16 in. 4 in. 15 in. 15 in. 4 in. 12 in.16 in. 13 in.14 in.9 in. 2 in.
13 in. 14 in. 14 in. 14 in. 13 in.2 in. 2 in.
16 in. 16 in. 16 in. 16 in.7 in. 8 in.
Conguration 1: Primary Conguration
Conguration 2 Conguration 5
Conguration 3
Conguration 4

12 © 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
5SECURE STANDARDS TO WALL
DRYWALL
DRILL 1/2 in. HOLE
AA
BB
A) Make sure each Standard is level, mark the screw holes in the Standards using a pencil. Predrill any necessary holes according to the illustration. Insert anchors if installing on a
concrete wall or toggle bolts if installing on drywall. Secure each Standard to wall using recommended hardware as shown. Use a phillips screw driver to tighten each panhead screw or bolt.
*It is recomended to test fit a 72 in. shelf in upper standards and a 48 in. shelf in the lower standards, measure plumbs, and carefully mark holes
before drilling
A
B
C
B) Attach standards by using standard extenders. Slide the standard extenders
into the slots as shown. Mark holes for drilling making sure the the standards are
level.
CONCRETE
DRILL 1/4 in. HOLES
CC
DD
CC
STUD
C

13© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
6INSTALL BRACKETS
Attach a bracket to each Standard where you expect to place a shelf.
1
2
A
B
C
D
D

14 © 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
7FOR SHELVES THAT REQUIRE CUTTING
Never allow more than a 6 in. overhang.
Place shelf on brackets. Allow an equal overhang (from brackets) on both sides. Measure amount to be cut. Remove shelf and cut with hacksaw or bolt cutter. Do not make cuts where
vertical spacers are on front lip of shelf.
MAX
6 in.

15© 2019 ClosetMaid LLC | Ocala, FL 34471 | 1-800-874-0008 | www.closetmaid.com
8INSTALL SHELVES
B) Rest shelf on each shelf bracket at desired location. Pull shelf forward and allow front to “drop” over nose of shelf brackets
(nose of each shelf bracket will fit between wires). Push shelf backwards so back wire fits into shelf bracket slots. Firmly pull
shelf forward at each bracket location to lock shelf into place.
A) Place shelf caps onto exposed shelf rod ends. E
EE
1
1
2
3
This manual suits for next models
1
Table of contents
Other Closet Maid Rack & Stand manuals

Closet Maid
Closet Maid 2894 User manual

Closet Maid
Closet Maid Portable Garment Rack 1090-31 User manual

Closet Maid
Closet Maid pro GARAGE User manual

Closet Maid
Closet Maid Outdoor Power Equipment Hang-Up 3559 User manual

Closet Maid
Closet Maid Pant Rack 33813 User manual

Closet Maid
Closet Maid In-Cabinet Spice Rack 3180 User manual

Closet Maid
Closet Maid Add-A-Hook 1129 User manual

Closet Maid
Closet Maid 9-Pair Shoe Rack 1039-31 User manual

Closet Maid
Closet Maid Rack Three-Tier 8024 User manual

Closet Maid
Closet Maid 58040 Installation instructions