Thank you for your trust and support in choosing our Evaporative Air Cooler. Please read this manual
carefully before using it. The Evaporative Air Cooler comes with the most advanced evaporative cooling
technology and modern management. It will make your life easier and more comfortable.
When the wind blows on your sweaty body, you will feel cool. This is the same principle at work. The
Circulating Pump continuously sucks water and equally distributes water to the CELDEK cooling pads via
the water distributor. When affected by the outside hot dry air, water evaporates from the cooling pads
contributing to a temperature drop by 5-12 degrees. Thus it produces fresh, cooler, and clean air.
1. Cooler must be placed in well-ventilated and dry place to ensure 100% fresh air is brought in.
2. Cooler must have enough air exhaust. 3600m3/h airflow requires up to 0.8m2 of exhaust area with
natural exhaust. Exhaust capacity should not be less than 85% of airflow with mechanical exhaust.
Mechanical exhaust system can be combined with natural exhaust.
3. Debug the cooler when operating for the first time. Ensure that the operating electric current is at the
rated current range.
4. Keep away any source of fire when assembling or operating the cooler.
5. Ensure the supply voltage is within the rated +/-10V range otherwise it will damage the cooler – cooler
may fail to start completely or cooler will start and stop frequently.
6. Keep the wall controller and control lines away from equipments with strong electromagnetic
interference or EMI – e.g. equipment with frequency speed controller, SCR temperature and speed
controller, high frequency heating circuit or super high power motor etc. It is better not to keep them in
the same power lines. If you must, please make sure distance between equipments is more than 30 cm.
7. This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities,
as well as lack of experience and knowledge unless there is supervision or instruction concerning use of
appliance by a person responsible for their safety. Children must be supervised to ensure the appliance is
not played with.
8. If the supply cord is damaged, replacement must be coursed through the manufacturer, its service agent
or similarly qualified persons in order to avoid any hazard.
1. Check if the supply voltage and supply frequency are the same as the rated ones. The proper voltage is
110±10V.
2. Make sure water to be used is clean with a steady hydraulic pressure, 0.2~0.6MPa(1.5~6kgf/cm2) if
connected directly to water source.
3. A globe-valve is needed near the intake hose and an extra hose connector is needed for cleaning.
4. Circuit breaker should be added on the feed circuit to protect the cooler, the wire net, and the safety of
people.
1. Take two sets of assembled frames (see Pic 1)
2. Use ST5x25 bolts to stabilize the assembled frame to the bottom of the water tank. Lock the bolts
securely with Phillips screwdriver. Pay close attention to the hole in the tank while installing (see Pic 2)
1. FOREWORD
2. PRINCIPLE AT WORK
5. GUIDE FOR INSTALLATION AND UNINSTALLATION OF TRUCKLES AND HORSE
3. ATTENTION
4. INSPECTION AND PREPARATION BEFORE ASSEMBLING
6. GUIDE FOR INSTALLATION AND UNINSTALLATION OF SIDE PANEL