ref. : 080 11226
080 11227
Page 9/10
This document is the property of COMANEX and cannot be disclosed or communicated without his prior consent
Comanex
) TROUBLE SHOOTING:
If after switch ON there isn’t any picture on the video monitor, check all the connections.
Problem Cause Remedy
The green light of the video
monitor is switched off
Check the good working of the switch.
Check the power is adapted (50/60Hz).
supply is switched off
Control the power (2 0 VAC).
Check the power cable of the control
console.
Check the good working of the switch.
Check the fuse 250V/2A.
video monitor
power on the video camera
Check that the video cable is well
connected to the BNC bulkhead of the
power supply.
The umbilical is damaged or in
short circuit
Check the continuity of the umbilical.
Check that pins 1 and 2 of the Jupiter
connectors aren’t cut or in short circuit.
Check that the power is available on the
BNC bulkhead marked TO CAMERA on
the power supply.
Check video monitor adjustments
Check the camera isn’t in front of an
object or a plain coloured (black or
white) wall in front of the camera.
bright light source (sun).
Check Pal standard on the video monitor.
Adjust the video monitor.