Contec AO-1604L-LPE User manual

Ver.1.04
.1.00er.1
AO-1604L-LPE 1
100KSPS 16-bit
4
ch Analog Output Board
for PCI Express (Low Profile)
AO-1604L-LPE
*Specifications, color and design of the products are subject to
change without notice.
This product is a Low Profile PCI Express bus-compliant
interface board used to provide an analog signal output function
on a PC.
This product is multifunction type with 16-bit analog output 4
channels, digital I/O and counter function.
This product carries buffer memory for 1K of data, allowing
sampling to be performed in a variety of trigger / clock conditions.
Windows/Linux driver is bundled with this product.
Possible to be used as a data recording device for MATLAB and
LabVIEW, with dedicated libraries.
High precision analog output 4 channels, each 4 channels
for digital I/O, counter 1 channel
This product has analog output (10µsec, 16-bit, 4 channels),
analog output control signal (LVTTL level 3 channels), digital I/O
(each 4 channels for LVTTL level), counter (32-bit, LVTTL level 1
channel).
The start/end of sampling can be controlled by software, an
external trigger, etc.
You can select from software, an external trigger to control the
start of sampling. You can select from completion of sampling for
a specified number of sessions, an external trigger or software to
control forcibly the end of sampling. The sampling cycle can be
selected from the internal clock or an external clock.
Safety design to adjust output voltage to 0V when power
supply is turned on
To prevent the unstable voltage and the connected device of D/A
converter from fault and malfunctions when the power supply is
turned on, the circuit is designed to adjust output voltage of the
analog output to 0V.
Equipped with buffer memory (1K data) that can be used in
the FIFO or RING format
The block contains buffer memory (1K data) that can be used in
the FIFO or RING format. This allows for background analog
output that does not depend on the operation status of the
software or PC.
Digital filter function included to prevent misdetection due to
chattering on external signals
A digital filter is included to prevent misdetection due to chattering
on the control signal (external trigger input signal, sampling clock
input signal, etc.), digital input signal and counter input signal.
(Except from external clock input signal and counter gate signal)
Support for both of low-profile and standard PCI slots
(interchangeable with a bundled bracket)
This product has each bracket for both low-profile size slot and
standard size slot. If you wish to mount this product in a
standard size slot, replace this with the standard size bracket.
Software-based calibration function
Calibration of analog output can be all performed by software.
Apart from the adjustment information prepared before shipment,
additional adjustment information can be stored according to the
use environment.
Windows/Linux compatible driver libraries are attached.
Using the attached driver library API-PAC(W32) makes it
possible to create applications of Window/Linux. In addition, a
diagnostic program by which the operations of hardware can be
checked is provided.
MATLAB and LabVIEW is supported by a plug-in of
dedicated library VI-DAQ.
Using the dedicated library MATLAB and VI-DAQ makes it
possible to make a LabVIEW application.
Features
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.04
.1.00er.1
AO-1604L-LPE 2
Item
Specification
Analog output
Isolated specification
Non-isolated
Number of output channels
4ch
Output range
Bipolar ±10V
Absolute max. output voltage
±3mA
Output impedance
1Ωor less
Resolution
16bit
Non-Linearity error *1
±5LSB
Conversion speed
10µsec [100KSPS]*2
Buffer memory
1k Word
Conversion start trigger
Software / external trigger
Conversion stop trigger
Number of sampling times / external trigger/software
External start signal
LVTTL level (Rising or falling edge can be selected
by software)
Digital filter (1µsec can be selected by software)
External stop signal
LVTTL level (Rising or falling edge can be selected
by software)
Digital filter (1µsec can be selected by software)
External clock signal
LVTTL level (Rising or falling edge can be selected
by software)
Digital I/O
Number of input channels
Non-isolated input 4ch (TTL level positive logic)
Number of output
channels
Non-isolated output 4ch (TTL level positive logic)
Counter
Number of channels
1ch
Counting system
Up count
Max. count
FFFFFFFFh (Binary data,32bit)
Number of external inputs
2 LVTTL level (Gate/Up)/ch
Gate (High level), Up (Rising edge)
Number of external outputs
1 LVTTL level, Count match output (positive logic,
pulse output)
Response frequency
10MHz (Max.)
Common section
I/O address
64 ports
Interruption level
Errors and various factors, One interrupt request line
as INTA
Used Connector
10250-52A2JL[3M] or equivalent to it
Power consumption 3.3VDC 400mA
12VDC 250mA
Operating condition
0 - 50°C, 10 - 90%RH (No condensation)
Bus specification
PCI Express Base Specification Rev. 1.0a x1
External dimension (mm)
121.69 (L) x 67.90 (H)
Weight
60g
Certification
RoHS,VCCI
*1: The non-linearity error means an error of approximately 0.1% occurs over the maximum
range at 0°C and 50°C ambient temperature.
*2: SPS = Samplings Per Second. The number of data that can be converted in one second
is shown.
Board Dimensions
[mm]
121.69(L)
67.90(H)
The standard outside
dimension(L) is the distance
from the end of the board
to the outer surface of
the slot cover.
Windows version of analog I/O driver API-AIO(WDM)
[Stored on the bundled Disk driver library API-PAC(W32)]
The API-AIO(WDM) is the Windows version driver library
software that provides products in the form of Win32 API
functions (DLL). Various sample programs such as Visual Basic
and Visual C++, etc and diagnostic program *1useful for
checking operation is provided.
For more details on the supported OS, applicable language and
new information, please visit the CONTEC’s Web site.
Linux version of analog I/O driver API-AIO(LNX)
[Stored on the bundled Disk driver library API-PAC(W32)]
The API-AIO(LNX) is the Linux version driver software which
provides device drivers (modules) by shared library and kernel
version. Various sample programs of gcc are provided.
For more details on the supported OS, applicable language and
new information, please visit the CONTEC’s Web site.
Data Acquisition library for MATLAB ML-DAQ
(Available for downloading (free of charge) from the
CONTEC web site.)
This is the library software which allows you to use our analog I/O
device products on MATLAB by the MathWorks. Each function is
offered in accordance with the interface which is integrated in
MATLAB’s Data Acquisition Toolbox.
For more details on the supported OS, applicable language and
new information, please visit the CONTEC’s Web site.
Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the
CONTEC web site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of
LabVIEW's Data Acquisition VI, allowing you to use various
devices without complicated settings.
For more details on the library and download of VI-DAQ, please
visit the CONTEC’s Web site.
Specification
Support Software
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.04
.1.00er.1
AO-1604L-LPE 3
Shield Cable with Two 50-Pin Mini-Ribbon Connector
:PCB50PS-0.5P (0.5m) , PCB50PS-1.5P (1.5m)
Shield Cable with One 50-Pin Mini-Ribbon Connector
:PCA50PS-0.5P (0.5m) , PCA50PS-1.5P (1.5m)
Screw Terminal Unit (M3 terminal block, 50 points)
: EPD-50A *1
BNC Connector Screw Terminal Unit
: ATP-8L *1*2
*1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately.
*2 Capable of using the analog input of up to 8ch, and analog output of up to 2ch.
* Check the CONTEC’s Web site for more information on these options.
Board [AO-1604L-LPE] …1
First step guide …1
Disk *1 [API-PAC(W32)] …1
Standard size bracket …1
Serial number label…1
Warranty Certificate…1
*1 The Disk contains the driver software and User’s Guide.
The on- product interface connector (CN1) is used when
connecting this product and the external devices.
CN1
Interface connector (CN1)
- Connector used
50-pin mini-ribbon connector
10250-52A2JL[mfd.by 3M]
- connector
10150-6000EL[mfd. by 3M]
Compatible
* Please refer to page 2 for more information on the supported cable and accessories.
Pin Assignment of CN1
Analog Output00 - Analog Output03
Analog output signal. The numbers
correspond to channel numbers.
Analog Ground
Analog ground.
AO External Start Trigger Input
External trigger input for starting analog
output sampling.
AO External Stop Trigger Input
External trigger input for stopping analog
output sampling.
AO External Sampling Clock Input
External sampling clock input for analog
output.
Digital Input00 - Digital Input03
Digital input signal.
Digital Output00 - Digital Output03
Digital output signal.
Counter Gate Control Input
Gate control input signal for counter.
Counter Up Clock Input
Count-up clock input signal for counter.
Counter Output
Counter output signal.
Digital Ground
Common digital ground for digital I/O
signals, external trigger inputs, external
sampling clock inputs, and counter I/O
signals.
Reserved
Reserved pin.
N.C.
No connection to this pin.
CAUTION
- Do not connect any of the outputs and power outputs to the
analog or digital ground.
Neither connect outputs to each other. Doing either can
result in a fault.
- digital signals may affect the analog signals. Accordingly,
analog and digital ground should be separated.
- Leave "Reserved" pins unconnected. Connecting these
pins may cause a fault in the product.
Cable & Connector (Option)
Accessories (Option)
Packing List
How to connect the connectors
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de
Ver.1.04
.1.00er.1
AO-1604L-LPE 4
This section shows how to connect the analog output signal by
using a flat cable or a shielded cable.
The following figure shows an example of flat cable connection.
Connect the signal source and ground to the CN1 analog output.
Analog Output 0..3*2
Analog Ground
BOARD CN1 Cable Target
The following figure shows an example of shield cable
connection. Use shielded cable if the distance between the signal
source and product is long or if you want to provide better
protection from noise. For each analog input channel on CN1,
connect the core wire to the signal line and connect the shielding
to ground.
Analog Ground
Shield cable
Analog Output 0..3*2
BOARD CN1 Target
*2 The number of channels depends on each product. The AO-1604L-LPE has four channels.
CAUTION
- When the power supply is turned on, the output voltage of all
channels becomes 0 V.
- If the product or the connected wire receives noise, or the
distance between the product and the target is long, data
may not be outputted properly.
- For analog output signal, the current capacity is ±3mA (Max.).
Check the specification of the connected device before
connecting the product.
- Do not short the analog output signal to analog ground,
digital ground, and/or power line. Doing so may damage
the product.
- Do not connect an analog output signal to any other analog
output, either on the product or on an external device, as this
may cause a fault on the product.
The following sections show examples of how to connect digital
I/O signals, counter I/O signals, and other control I/O signals
(external trigger input signals, sampling clock input signals, etc.).
All the digital I/O signals and control signals are LVTTL level
signals.
Digital Input Connection
10kΩ
Digital Input
Digital Ground
BOARD CN1 Cable Target
Digital Output Connection
Digital Ground
BOARD CN1 Cable Target
Digital Output
IOL=8mA
About the counter input control signal
Counter Gate Control Input (refer to the chapter 3 Connector Pin
Assignment) acts as an input that validate or invalidate the input
of an external clock for the counter. This function enables the
control of an external clock input for the counter. The external
clock for the counter is effective when input is "High", and invalid
when input is "Low". If unconnected, it is a pull-up in the board
(card) and remains "High". Therefore the external clock for the
counter is effective when the counter gate control input is not
connected.
CAUTION
- Do not short the output signals to analog ground, digital
ground, and/or power line. Doing so may damage the
board.
- Do not connect a digital output signal to any other digital
output, either on the board or on an external device, as this
may cause a fault on the board.
4 Digital Input / 4 Digital Output
External Trigger Inputs
Counter Input / Output
PCI Express Bus
CN1
FPGA
DC/DC
converter
4 Analog Outputs
DA
Converter
DA
Converter DA
Converter
DA
Converter
Digital I/O signals, Counter signals and
Control signals Connection
Block Diagram
Analog Output Signal Connection
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de

Other Contec I/O System manuals

Contec AO-1604CI3-PCI User manual

Contec

Contec AO-1604CI3-PCI User manual

Contec DIO-128SLX-USB User manual

Contec

Contec DIO-128SLX-USB User manual

Contec F&eIT Series User manual

Contec

Contec F&eIT Series User manual

Contec ADA16-8/2(LPCI)L User manual

Contec

Contec ADA16-8/2(LPCI)L User manual

Contec PIO-32/32L User manual

Contec

Contec PIO-32/32L User manual

Contec DIO-3232L-PE User manual

Contec

Contec DIO-3232L-PE User manual

Contec DA16-16L User manual

Contec

Contec DA16-16L User manual

Contec COM-4CX-USB User manual

Contec

Contec COM-4CX-USB User manual

Contec CONPROSYS CPS-MM-LC User manual

Contec

Contec CONPROSYS CPS-MM-LC User manual

Contec PIO-32/32RL(PCI)H User manual

Contec

Contec PIO-32/32RL(PCI)H User manual

Contec COM-4CX-USB User manual

Contec

Contec COM-4CX-USB User manual

Contec PO-32L(PCI)H User manual

Contec

Contec PO-32L(PCI)H User manual

Contec PIO-32H(PCI)H User manual

Contec

Contec PIO-32H(PCI)H User manual

Contec AD12-64(PCI) User manual

Contec

Contec AD12-64(PCI) User manual

Contec PIO-64L(PCI)H User manual

Contec

Contec PIO-64L(PCI)H User manual

Contec CPS-MC341-DS1 -111 User manual

Contec

Contec CPS-MC341-DS1 -111 User manual

Contec AO-1604LX-USB User manual

Contec

Contec AO-1604LX-USB User manual

Contec CM-32L Operator's manual

Contec

Contec CM-32L Operator's manual

Contec F&eIT Series User manual

Contec

Contec F&eIT Series User manual

Contec N Series User manual

Contec

Contec N Series User manual

Contec DIO-1616TB-PE User manual

Contec

Contec DIO-1616TB-PE User manual

Contec CONPROSYS nano CPSN-DI-16BCL User manual

Contec

Contec CONPROSYS nano CPSN-DI-16BCL User manual

Contec DIO-4/4(FIT)GY User manual

Contec

Contec DIO-4/4(FIT)GY User manual

Contec DA12-16PCI User manual

Contec

Contec DA12-16PCI User manual

Popular I/O System manuals by other brands

SinoCon KonNad C2000-A2-SMX2800-AC1 user manual

SinoCon

SinoCon KonNad C2000-A2-SMX2800-AC1 user manual

SMC Networks EX500-IE1 Installation & maintenance manual

SMC Networks

SMC Networks EX500-IE1 Installation & maintenance manual

Acces I/O products 104-IDI-48 Series user manual

Acces I/O products

Acces I/O products 104-IDI-48 Series user manual

Allen-Bradley 1719 Ex I/O user manual

Allen-Bradley

Allen-Bradley 1719 Ex I/O user manual

Bosch B308 user manual

Bosch

Bosch B308 user manual

Banner MultiHop Series quick start guide

Banner

Banner MultiHop Series quick start guide

Simply Automated UMI User instructions

Simply Automated

Simply Automated UMI User instructions

Smarteh LONGO LPC-2 user manual

Smarteh

Smarteh LONGO LPC-2 user manual

NCR 7649-K021 Kit instructions

NCR

NCR 7649-K021 Kit instructions

Tyco Software House AS0073-001 datasheet

Tyco

Tyco Software House AS0073-001 datasheet

WEG CFW300-IOADR Installation, configuration and operations guide

WEG

WEG CFW300-IOADR Installation, configuration and operations guide

Panasonic AV-HS04M6 operating instructions

Panasonic

Panasonic AV-HS04M6 operating instructions

Delta Electronics Analog Input/Output Mixed Module DVP06XA-S instruction sheet

Delta Electronics

Delta Electronics Analog Input/Output Mixed Module DVP06XA-S instruction sheet

INTELLIGENT CONTROL IOTRouter ZHC4013 Application guide

INTELLIGENT CONTROL

INTELLIGENT CONTROL IOTRouter ZHC4013 Application guide

National Instruments 9220 CALIBRATION PROCEDURE

National Instruments

National Instruments 9220 CALIBRATION PROCEDURE

Omron NX-ID user manual

Omron

Omron NX-ID user manual

Hitachi HS2160EIO61H user manual

Hitachi

Hitachi HS2160EIO61H user manual

National Instruments FlexRIO NI 6581B Getting started guide

National Instruments

National Instruments FlexRIO NI 6581B Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.