4
W415-0162 / E / 03.05.04
4 NUTS
SHIPPING
BRACKET
CS600: Maximum input is 35,000 BTU/hr for natu-
ral gas and 31,500 BTU/hr for propane. This stove is
approved for bedroom and bed-sitting room installa-
tions.
CDVS600: TOP VENT / REAR VENT
VERTICAL TERMINATION: Maximum in-
put is 35,000 BTU/hr for natural gas and 31,500 BTU/hr
for propane. Maximum output for natural gas is 27,300
BTU/hratan efficiency of 78%. Maximumoutputforpro-
pane is 24,570 BTU/hr at an efficiency of 78%. Maxi-
mumA.F.U.E.(annualfuel utilization efficiency) rating is
72% for natural gas and 71% for propane.
REAR VENTHORIZONTAL TERMINA-
TION: Maximum input is 21,000 BTU/hr for natural
and propane gas. This application requires changing
the main burner orifice.
Thisstoveisnotapprovedfor closet or recessedinstal-
lations. It is approved for bathroom, bedroom and bed-
sittingroom installations.
This stove may be installed in an aftermarket perma-
nently located, manufactured(mobile)home, where not
prohibited by local codes.
Change in flame appearance from "HI" to "LO" is more evi-
dentinnaturalgasthanin propane. Expansion /contraction
noises during heating up and cooling down cycles are nor-
mal and to be expected.
Thisapplianceisonlyforusewiththetypeofgasindicated
on the rating plate. (See page 14). This appliance is not
convertible for use with other gases, unless a certified kit
is used.
INSTALLER: It is your responsiblity to check off the
appropriate box on the rating plate according to the
model, venting and gas type of the unit.
Do not use abrasive cleaners to clean these parts. Buff
lightly with a clean dry cloth.
The glass is 3/16" ceramic glass available from your
Continental/ Wolf SteelLtd.dealer.DONOTSUBSTITUTE
MATERIALS. Clean the glass after the first 10 hours of op-
eration with a recommended gas fireplace glass cleaner.
Thereafter clean as required. DO NOT CLEAN GLASS
WHEN HOT! If the glass is not kept clean permanent dis-
colouration and / or blemishes may result.
Toavoidthestovebeingdamaged during shipping, aship-
ping bracket has been used and must be unbolted before
the stove can be installed.
1. Removethefournutsholdingthe shipping bracket tothe
bottom of the stove.
2. Lift the stove up and away from the skid to clear the
threaded bolts sticking through the bracket. Set down on a
flat surface. The stove top is not secured to the unit.
3. Discard the nuts, bracket and the skid. FIGURE 1
THIS GAS STOVE SHOULD BE INSTALLED ANDSERVICED
BY A QUALIFIED INSTALLER to conform with local codes.
Installationpracticesvaryfromregiontoregionand itisimportant
toknow the specificsthatapplyto your area,
forexample:in MassachusettsState:
• The fireplace damper must be removed or welded in the open
position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed plumber
or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN1-B149
Installation Code in Canada or to the National Fuel Gas Code,
ANSIZ223.1,andNFPA54intheUnitedStates. Mobile home
installationmustconform with local codes. Intheabsenceof
localcodes,install to the current standardforgasequipped
mobilehousingCAN/CSA Z240 MH Series inCanadaorthe
manufactured home construction and safety standard, Title 24
CFR, part 3280, or the Fire Safety Criteria for manufactured
homeinstallations,SitesandCommunityStandard ANSI/NFPA
501A in the United States.
Purge all gas lines with the glass door of the stove removed.
Assure that a continuous gas flow is at the burner before re-
installing the door.
Under extreme vent configurations, allow several minutes (5-
15) for the flame to stabilize after ignition.
It is recommended that all horizontal runs have a ¼ inch rise
per foot.
Objects placed in front of the stove must be kept a minimum
of 48" away from the front face of the unit.
The stove and its individual shutoff valve must be disconnected
fromthegassupplypipingsystemduringanypressuretestingof
thatsystemattestpressuresinexcessof1/2psig(3.5kPa).The
stove must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testingofthegassupplypiping systemattestpressuresequalto
or less than ½ psig (3.5 kPa).
The stove, when installed with a blower, must be electrically
connectedandgrounded in accordance with localcodes.Inthe
absence of local codes, use the current CSA C22.1 CANADIAN
ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996
NATIONAL ELECTRICAL CODE intheUnitedStates.Theblower
powercordmustbeconnectedintoaproperlygroundedreceptacle.
The grounding prong must not be removed from the cord plug.
FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-
FIREDTOASSUREITS OPERATIONANDQUALITY!
Minimuminletgassupplypressureis4.5incheswatercolumnfor
natural gas and 11 inches water column for propane. Maximum
inletgaspressureis7incheswatercolumnfornaturalgasand13
incheswatercolumnforpropane.Whenthevalveissetto"HI",the
manifoldpressureunderflowconditionsis3.5incheswatercolumn
fornaturalgasand10incheswatercolumnforpropane.Whenthe
fireplaceisinstalledatelevationsabove4,500ft,andintheabsence
ofspecificrecommendationsfromthelocalauthorityhavingjuris-
diction,thecertifiedhighaltitudeinputratingshallbereducedatthe
rateof4%foreachadditional1,000ft.
GENERAL INSTRUCTIONS
GENERAL INFORMATION
CARE OF GLASS, AND PLATED PARTS
SHIPPING BRACKET