Cosa Xpress-5B/54 User manual

Ceiling Fan
Xpress-5B/54
Xpress-5B/40
Instruction
Manual
Version: 2019 V1

Warning
Installation and maintenance work shall only be performed by qualified persons, familiar with local
code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing
wiring work according to the wiring diagram.
The unit must be GROUNDED to prevent possible hazard due to insulation failure.
The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby
the suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent
electrocution.
Tighten the blade firmly using a screw driver.
Blades that are detached from the unit during operation will cause serious injuries and property
damages.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure
that the blade is fully static before doing any maintenance work.
1 - 2
4
4 - 6
8 - 9
9 - 10
10
11
11 - 12
12
3

Canopy
Downrod
Coupling Cover
Motor Assembly
Blade
Switch Housing
3
3
DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks
which may result in fire hazards.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the
manufacturer, its service agent or suitably qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a
sufficient strength to withstand 4 times the weight of the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer, its service agent or
suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing
conductor. The earthing terminal in the fan assembly should be such that should any part of the
suspension system fall off, the body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid
from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF”
position.
If this is not done, the unit’s fans will start turning automatically when power resumes, posing a
hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral
oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive
heat or chemical reaction.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors
respectively.
Don’t use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling
fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed by the manufactur-
er, its service agent or suitably qualified persons.
2
Transmitter Kit
Transmitter &
Holder x 1
AAA
AAA
Battery x 2
Blade Holder
Screw x 11
Bolt x 2
Assembly Kit
FAN OFF
2
13
4
6H
1H 3H

4
Green/
Yellow (E)
Washer & Nut
Clevis Pin
Clamp the downrod with the
2 screws on the coupling to
prevent shaking during
operation.
5

7
Brown (L)
Blue (N)
To Motor
Brown (L)
Blue (N)
House Supply Wires
Brown (L)
Blue (N) Green/Yellow (E)
From Motor
Brown (L)
Blue (N)
Green/Yellow (E)
Step 7 - Connect the Connectors from Fan and Receiver. Connect the wires from the
receiver to House’s Supply Wire.
Step 5 - Fix the blade to the motor suing the screws provided.
IMPORTANT : Assemble the blades only after the ceiling fan is mounted on the
hook.
6

Function of Transmitter
9
1 - Speed 1
2 - Speed 2
3 - Speed 3
4 - Speed 4
FAN OFF - Stop the fan
1H - Fan stops after 1hr
3H - Fan stops after 3hr
6H - Fan stops after 6hr
8
The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more
fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
a) Insert the 2 pcs of batteries (provided) into transmitter.
b) Turn on the power supply (wall switch) to the fan.
c) Within 10 sec, press and hold the “1” and “2” button for 3 sec. Once the receiver has
detected the frequency, transmitter will “Beep Beep” twice. Programming process is
completed and fan is ready to use.
If the fan is not responding to the transmitter, repeat Step 1b.
Press and hold
for 3 sec
Transmitter Learning Process
FAN OFF
2
13
4
6H
1H 3H
FAN OFF
2
13
4
6H
1H 3H
The transmitter & receiver is incorporated with last memory function. This function
stores your last setting in memory and the next time you turn on the fan, fan will
operate as the last setting.

10 11
To Fan L Brown
To Fan N Blue
Main
PCB
Red
Yellow
Grey
E
L
N
Motor
Thermal
Fuse
(Inside
Motor)
White
Pink
Motor
Capacitor
Model
No. of Blades
Fan Width
Motor RPM
Voltage
Wattage
Nett Weight
Xpress-5B/54
5
54”
110 - 225
220-240V~ 50Hz
20W - 80W
6.2kg
Xpress-5B/40
5
40”
110 - 230
220-240V~ 50Hz
20W - 80W
6.3kg

12
If you need any technical assistance or faulty report, please contact our customer service
centre at :
Alpha Home Appliances Sdn. Bhd. (390258-H)
Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32,
40460 Shah Alam, Selangor.
Tel : 03-5740 6666 Fax : 03-5740 8220
Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
Tel : 07-353 4833 / 4933 Fax : 07-355 4233
Melaka : 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
Tel : 06-292 6292 / 6293 Fax : 06-292 6296
Ipoh : 16, Jalan Tasek Timur, Taman Tasek Indra, 31400 Ipoh, Perak.
Tel : 05-545 2282 / 547 2282 Fax : 05-547 6282
Penang : 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
Tel : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966
Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
Tel : 09-516 5226 Fax : 09-513 9226
Xpress-5B/54 1372mm (4’ 6”)
Xpress-5B/40 1060mm (3’ 4”)
340mm (1’1”)
400mm (1’4”)
This manual suits for next models
1
Other Cosa Fan manuals
Popular Fan manuals by other brands

Carrier
Carrier CRECOMZR077A00 installation instructions

Inspire
Inspire Vicen Assembly, Use, Maintenance Manual

Adler
Adler AD 7319 user manual

System air
System air BR 355D2 IE3 Installation and operating instructions

WHISPER KOOL
WHISPER KOOL XLT Series installation guide

Princess
Princess 350000 instruction manual

Pro Breeze
Pro Breeze PB-01 instruction manual

Ebmpapst
Ebmpapst A2S130-AB03-15 operating instructions

Three Sixty
Three Sixty Arumi AC Series Owner's and installer's manual

AGI
AGI AIRLANCO C2000 Installation and operation manual

Ebmpapst
Ebmpapst W2E250-EC01-07 operating instructions

Air King
Air King AK150LS Series Specifications