4.1 - Intended use
and functions of the
appliance
This condensation-type gas appliance,
is designed to be used for central
heating and producing domestic hot
water for civil use.
Fit the boiler to the system according
to the most suitable residual curve
head (see gures 6 and 7).
The maximum output heat is always
guaranteed for the production of
domestic hot water since, on each
request, the heating service switches
off.
Follow the specic procedure in
section 9.13 for the adjustment of the
domestic hot water temperature.
Depending on the model chosen, the
following system types can be created:
A- NOVADENS -- ” “. By means of
this boiler, a system can be created
for the production of instant domestic
hot water and a heating system
with heating elements functioning at
temperatures ranging between 30°C
and 80°C. An example of this type of
system is shown in gure 2.
B- NOVADENS -- “B”. By means of
this boiler, a system can be created
for the production of domestic hot
water using a storage tank, BWR or
equivalent model and a heating system
with heating elements functioning at
temperatures ranging between 30°C
and 80°C. An example of this type of
system is shown in gure 4.
C- NOVADENS -- “C”. By means of
this boiler, a system can be created for
the only heating with heating elements
functioning at temperatures ranging
between 30°C and 80°C. An example
of this type of system is shown in gure
3.
In this model is moreover possible to
connect, also after the installation,
en storage tank model BWR lled
up through one external valve to the
boiler.
D- NOVADENS -- “P”. By means of
this boiler, a system can be created
for the production of instant domestic
hot water and a heating system
with heating elements functioning at
temperatures ranging between 30°C
and 80°C. An example of this type of
system is shown in gure 2.
All the boiler versions described
previously can be connected to a
room thermostat for the setting of
the heating. Or, so as to improve
the quality of the heating service,
it is possible to connect an external
temperature sensor (Climatic heat
adjustment) so as to automatically
set the supply temperature in relation
to the external temperature; the
room thermostat, in this case, can
make a compensation of the room
temperature. The room compensation
can be of an ON /OFF type or two-
stage.
For further information on the Climatic
heat adjustment, refer to section 7.4.
For take advantage of the rendering
characteristics of boiler, it is
advised to connect it to the CR04
cronothermostat, (see chapter
5.14.5), what it will regulate the
temperature of supply to the
radiators in continuous and linear
way, to maintain the temperature
environment planned.
The boiler must be connected to
a heating system and a domestic
hot water supply, with compatible
specications, performance and
power rating.
Before installation, thoroughly ush
the heating and plumbing systems
of any residue or impurities which
might compromise the smooth
running of the boiler.
This boiler is not designed for
outside installation.
Choose a sheltered place where
it is protected from atmospheric
elements including frost.
Refer to gure 9 for minimum
clearance distances for installation
and future maintenance.
4 - FUNCTIONS OF THE APPLIANCE
E- NOVADENS -- “0834”. By means
of this boiler, a system can be created
for the production of instant domestic
hot water and a heating system
with heating elements functioning at
temperatures ranging between 20°C
and 45°C. An example of this type of
system is shown in gure 2.
F- NOVADENS -- “B0834”. By means
of this boiler, a system can be created
for the production of domestic hot
water using a storage tank, BWR or
equivalent model and a heating system
with heating elements functioning at
temperatures ranging between 20°C
and 30°C. An example of this type of
system is shown in gure 4.
G- NOVADENS -- “C0834”. By means
of this boiler, a system can be created
for the only heating with heating
elements functioning at temperatures
ranging between 20°C and 45°C.
An example of this type of system is
shown in gure 3.
In this model is moreover possible to
connect, also after the installation,
en storage tank model BWR lled
up through one external valve to the
boiler.
H- NOVADENS -- “P0834”. By means
of this boiler, a system can be created
for the production of instant domestic
hot water and a heating system
with heating elements functioning at
temperatures ranging between 20°C
and 45°C. An example of this type of
system is shown in gure 2.
In all the boiler versions described
previously, connection of the domestic
hot water service is not indispensable;
if the boiler is required solely for central
heating purposes, it is sufcient to
connect the cold water pipe so as to ll
the heating system and close the tting
of the d.h.w. outlet.
All the NOVADENS -- or NOVADENS
--0834 model boilers, can also be
connected subsequently for the
installation of a B70 C series storage
tank (see gure 5)