7
3 - USE
Figure 3 - Parameters within the “Users’ Menu”
“USERS’ MENU”
Adjustmentof thegradient of theline asper figu-
re 4. Visible only with climatic adjustment active.
(Seeinstallation andinstruction manual).
Adjustment of “Minimum heating temperature”.
Visible only with climatic adjustment active. (See
installationand instructionmanual).
Adjustment of “Maximum heating temperature”.
Visible only with climatic adjustment active. (See
installationand instructionmanual).
Adjustmentof the parallelism“b”of thelineas per
figure 4. Visible only with climatic adjustment
active.(See installationand instruction manual).
Display of calculated heating temperature (if
climaticadjustment active)ordisplay oftempera-
ture set via the control “7” as per figure 1.
Displayof domestic hotwatertemperature set via
the control “11” as per figure 1.
Displayof lasterror registered.
Display of last block which occurred.
Settingrange: 0.1-5.0
Settingrange:20°C-60°Cforradiantpanels,30°C-60°C
forradiators.
Settingrange: 45°C for radiant panels, 80°Cforradiators.
Onlydisplay.Theregulationiscarriedoutusingthecontrol
“7”asper figure 1.It canadopt valuesrangingbetween-
10°Cand+10°C
Onlydisplay. Itcan adoptvalues ranging between20°C
and80°C
Onlydisplay. Itcan adoptvalues ranging between40°C
and70°C
Only display. It can adopt the values indicated in the
installation and maintenance manual
Only display. It can adopt the values indicated in the
installation and maintenance manual
PARAMETER DESCRIPTION INFORMATION ON DISPLAY “2”
3.7 - Summer mode
To disable the heating functions for a
prolonged period, leaving only the
domestic hot water function, switch the
heatingtemperature tominimum,untilthe
wordingOFFappears,byturningknob “7”
offigure1.
3.8 - Winter mode
In Winter mode, by means of the pump ,
the boiler sends the water to the system
at the temperature set using knob “7” of
figure1.
When the temperature inside the boiler
reaches the temperature set, the burner
starts to modulate the flame so as to
reduce the output to a minimum. If the
temperaturerisesfurther,theburnershuts
down.
Simultaneously, the pump which sends
the water to the system is switched on
andoff by theroom thermostat. Thiscan
be noted, because indicator “6” of figure
1switches on andoffin correspondence
with the on and off of the pump.
Atfirst the pumpmay makeanoise. This
is due to the presence of residual air in
the hydraulic system which will soon
disappearon its own.
Werecommendkeeping the temperature
set using knob “7” at the point shown by
the symbols on the panel for a rational
useof theboiler. Ifit isa particularly cold
Winter and it is difficult to maintain the
desired temperature, turn knob “7” to
graduallyhighervalues.
3.9 - Adjusting the
heating temperature
To set the heating temperature, turn
control knob “7” of figure 1. As soon as
the knob is touched, will blink on
displayandthe temperature being set will
appear on display “2”. As a rule, it is
sufficient to turn control knob “7” to the
half-wayposition.Ifitisaparticularlycold
Winter, progressively increase the
temperatureby rotating control“/”.
3.10 - Adjusting the
heating temperature
with climatic
adjustment
The adjustment of the heating
temperature, in the event that climatic
adjustment has been set, is carried out
by turning control “7” as per figure 1.As
soon as the control is touched, display
“1” show a flashing and display “2”
shows the value in °C of translation on a
parallel with the adjustment curve (see
figure4,detail“b”.Asa rule,it is sufficient
to adjust control “7” to the half-way
position.If the Winterisparticularly rigid,
progressively increase the temperature
using control “7” until the temperature
inside the rooms is satisfactory. If the
comfort produced by the climatic
adjustment is not satisfactory (too hot,
toocold,roomtemperature not constant)