INSTALLATION GUIDE
HOW TO POSITION AND PROGRAM THE FLASH PROGRAMMER 2S
PRODUCT FUNCTIONS
•Centralised programming for two heating zones
using two temperature modes:
- Comfort temperature
- Reduced temperature
•Manual override function in comfort and reduced mode for each room.
PRINCIPLE OF OPERATION
•Convectors equipped with a suitable electromechanical thermostat:
Reduced temperature obtained by supplying a resistance, which overrides the sensing element of the
thermostat.
•Convectors equipped with a suitable electronic thermostat:
Reduced temperature achieved by delivering an alternating signal (coding adopted by all designers since
January 1994)
TECHNICAL CHARACTERISTICS
•Time switch: Electronic clock with day and week programs.
•Power backup: By lithium battery, backup guarantee for a total of 3 years minimum against mains failure
(battery life: 10 years)
•Program increments: 1 minute
•Number of zones: 2
•Total maximum current rating: 0.5A
•Dimensions: 167mm x 84mm x 44mm
INSTALLATION
1Unscrew the time switch fixing
screw
2 Separate the base plate from
the casing using a screwdriver
3Surface-Mounted base with 2off
screw fixings Ø3mm maximum
4Electrical connections (see page 2)
IMPORTANT Insert the flying
lead from the display panel into the
socket on the circuit board as shown
5Put outer casing back on
6Put back in and tighten the
time switch fixing screw 1