4 Copyright © 2019, Critical Link LLC
60-000047-1A
Figure 3 Open Dialog
7. Select the “MityCAM-120MXS” camera from the list and press OK.
a. It may take approximately 5 seconds for the camera to connect with the GenTL Viewer
software.
8. To do a multi-image capture, live video, perform the following steps:
a. Select one of the “Pixel Formats”, each of these controls the bit-depth of the image and
how the pixel data will be converted to color/greyscale.
Available options are:
Mono8 for 120MXSM, data is scaled to 8 bits per pixel
Mono12p for 120MXSM, data is scaled to 12 bits per pixel
BayerRG8 for 120MXSC, data is scaled to 8 bits per pixel color image
BayerRG12p for 120MXSC, data is scaled to 12 bits per pixel color image
BayerRG8IR for 120MXSI, data is scaled to 8 bits per pixel color image + IR
BayerRG12pIR for 120MXSI, data is scaled to 12 bits per pixel color image +IR
b. The Exposure and Frame Rate can be changed.
c. Acquisition Mode needs to be set to Continuous for live video or Multi-frame for burst
captures.
d. Press the play button to start captures.