manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Adapter
  8. •
  9. CTC Union IMC-100M-PH12 User manual

CTC Union IMC-100M-PH12 User manual

This manual suits for next models

1

Popular Adapter manuals by other brands

Mini Gadgets BB2Outlet user manual

Mini Gadgets

Mini Gadgets BB2Outlet user manual

LSI LSISAS3442E-R Quick installation guide

LSI

LSI LSISAS3442E-R Quick installation guide

Moeller BBA -16 Series installation instructions

Moeller

Moeller BBA -16 Series installation instructions

Acer MWA3 quick start guide

Acer

Acer MWA3 quick start guide

Connect Tech ADG095 user guide

Connect Tech

Connect Tech ADG095 user guide

cable matters 604002 user manual

cable matters

cable matters 604002 user manual

Solwise PL-85PEW Easy start

Solwise

Solwise PL-85PEW Easy start

HP Photosmart 7100 user guide

HP

HP Photosmart 7100 user guide

HP E2494A installation guide

HP

HP E2494A installation guide

StarTech.com USB150WN1X1 quick start guide

StarTech.com

StarTech.com USB150WN1X1 quick start guide

Lindy 43198 user manual

Lindy

Lindy 43198 user manual

A&D AD-8527 instruction manual

A&D

A&D AD-8527 instruction manual

Motorola WU830G user guide

Motorola

Motorola WU830G user guide

Hawking HUF2 Specifications

Hawking

Hawking HUF2 Specifications

Allen-Bradley E3 Plus installation instructions

Allen-Bradley

Allen-Bradley E3 Plus installation instructions

Trust BT-2210Tp manual

Trust

Trust BT-2210Tp manual

HP NC7170 overview

HP

HP NC7170 overview

Uconnect BLE-485C user manual

Uconnect

Uconnect BLE-485C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Introduction
IMC-100M-PH(E)12 are Fast Ethernet PoE (Power over Ethernet)
managed media converters that support conversion between
electrical 10/100Base-TX and optical 100Base-FX Ethernet. Housed in
rugged DIN rail or wall mountable enclosures, these converters are
designed for harsh environments, such as industrial networking and
intelligent transportation systems (ITS) and are also suitable for
many military and utility market applications where environmental
conditions exceed commercial product specifications.
Features
Redundant dual DC inputs 12/24/48VDC and built-in very high
efficient power booster
Constant and regulated PoE output voltage at 55VDC
Provides IEEE 802.3at PoE output (30W)
IP30 rugged metal housing
Wide temperature range -20°C ~75°C (IMC-100M-PHE12)
Supports many advanced Ethernet L2 functions
Industrial grade EMS, EMI, EN 50121-4, EN61000-6-2,
EN61000-6-4
Specifications
Optical Interface
Standards: IEEE 802.3u
Speed: 100M
Connector: SC or ST
Multimode (2km) 50/125um, 62.5/125um
Single mode (30km or 50km) 9/125um
Wavelength: 1310nm (S/M or M/M)
Ethernet Interface
Standards: IEEE802.3, 802.3u,
Connector: RJ-45 (shielded)
Auto MDI/MDI-X
Speed: 10/100M (Auto)
Duplex: Full/Half (Auto)
Link Fault Pass Through (LFP)
Jumbo Frames: 9K bytes
Power over Ethernet
1 PoE Enabled port
PoE configuration & monitoring
Supports IEEE802.3af 15.4W PoE & IEEE802.3at 30W PoE+
Positive (VCC+) pins 1, 2; Negative (VCC-) pins 3, 6
Data: 1, 2, 3, 6 pins
Quick Installation Guide
IMC-100M-PH12
IMC-100M-PHE12
Industrial Grade Fast Ethernet PoE+ Managed Media Converters
Specifications (cont.)
Power
Absolute Range: 9.6VDC~57VDC
Reverse Polarity Protection: Yes
Dual Power Inputs: Yes
Connector: Removable terminal block
Consumption:
Items
Input Voltage
Total Power
Consumption
Device Power
Consumption
PoE
Budget
Boost
Efficiency
12VDC
34.4W
3.9W
30W
98.4%
24VDC
34.9W
4.5W
30W
98.7%
48VDC
35.4W
4.7W
30W
97.7%
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 106 mm (D) x 62.5 mm (W) x 134.8 mm (H)
Mounting: DIN-Rail, Wall Mount (Kits included)
Weight: 655g
Environmental
Operating Temperature: -10°C~60°C-IMC-100M-PH12
-20°C~75°C-IMC-100M-PHE12
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC, FCC Part 15 Subpart
B Class A, CE EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength:
300A/m, Criteria A
Safety: UL60950-1 (Pending)
Shock: EN60068-2-27
Freefall: EN60068-2-32
Vibration: EN60068-2-6
MTBF (MIL-HDBK-217): 410,235 hours
[email protected]
V1.0
- 2 -
- 1 -
www.ctcu.com
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
T+886-2-26591021
F+886-2-26590237
E[email protected]
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60 Zhouzi St., Neihu District, Taipei 114
Taiwan
© 2014 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
Connectors
LAN and Fiber Connection
IMC-100M-PH(E)12 media converters have one electrical LAN
port and one fiber port on the front panel. The LAN port that
utilizes shielded RJ-45 connectors supports 10/100M; while the
fiber port support fixed speed 100M.
PoE Port
The LAN port supports PoE (Power over Ethernet) per
IEEE802.3af (15.4W) or IEEE802.3at (30W) for connection to
standard PoE PD (Power Devices) such as IP Cameras, Access
Points, IP Phones, Digital Signage, etc. PoE eliminates the need to
run separate power to these devices thereby simplifying
deployment and reducing expenses.
The LAN port may also connect to any non-PoE device for
normal Ethernet transmission without any damage to the non-
PoE device or to this device.
RJ-45 Ethernet Port Pinouts
Figure 3. RJ-45 Ethernet Port Pinouts
‘Default’ Push Button
The ‘Default’ push-button provides the following two functions:
Function
Press
and hold
for~
Description
Reset
3~8
seconds
Using a ball-point pen, press the ‘Default’
button and hold for 3~8 seconds then
release. The converter will clear all unsaved
settings and will be restarted.
Return to
factory
defaults
10
seconds
or longer
Using a ball-point pen, press the ‘Default’
button and hold for 10 seconds (or longer)
then release. DO NOT POWER OFF and allow
the device to again fully reboot (about 25
seconds). Then, all factory defaults have
been returned.
LED Indicators
LED
Color
Definition
PWR1/
PWR2
Green
Power is connected and active at the
PWR1/PWR2 input terminal connection.
Off
Power is not connected.
Fault
Amber
Fiber link loss, TP link loss or either one
power loss
Off
Normal operation with no power, fiber or
TP faults.
Fiber
LINK/ACT
Green
Fiber port has optical link.
Blinking
Blinking when there is data traffic.
Off
No optical link.
Fiber
Speed
Green
The fiber connected speed is 100M.
LAN
LINK/ACT
Green
LAN port has a link.
Blinking
Blinking when there is Ethernet traffic.
Off
No Ethernet link.
LAN Speed
Green
The UTP (LAN) speed is 100M.
Off
The UTP (LAN) speed is 10M.
PoE
Green
The respective LAN port has successfully
negotiated PoE and is supplying output
power to the remote connected PD.
Blinking
One of the PoE faults (overload, short
circuit, port failure at startup) occurs.
Blinking
twice
The remote PD device performs power
reset.
Off
PD is not connected or output power is not
provided.
RJ-45 Ethernet & PoE Pin Assignments
Pin
No.
RJ-45 Ethernet
100Base-TX
PoE Output
1
RX+
V+
2
RX-
V+
3
TX+
V-
4
-
5
-
6
TX-
V-
7
-
8
-
Power and Alarm
Power
(PWR1, PWR2)
There are input connectors for two power
sources on the terminal block. Only one
power source is required for normal
operation. The second power source input
may be provided for redundancy.
Alarm
The alarm relay contact can be wired into an
alarm circuit which senses an alarm condition
when the contact is broken. The alarm relay
is normally closed when there is no alarm
condition (See Figure 5). The alarm
conditions are user programmable through
management to include power and link
faults. Please note that the alarm relay
contact can only support 1A current at
24VDC. Do not apply voltage and current that
exceed these specifications.
Installation
The converter comes with both wall mount and DIN rail
hardware brackets. When installing the DIN rail bracket, be sure
to correctly align the orientation pin.
Figure 6. DIN Rail Figure 7. Wall Mount
The converter with DIN Rail bracket has a steel spring in the
upper rail of the bracket. This spring is compressed for mounting
and un-mounting by applying downward force.
Figure 8. Mounting Figure 9.Un-mounting
Application
Figure 1. IMC-100M-PH(E)12 Front Panel
- 5 -
Figure 4. Terminal Block
- 3 -
- 4 -
www.ctcu.com
- 6 -
Fault
Figure 5. Alarm
Relay Circuit
Normally Closed
(NC)