CUE touchCUE-S User manual

User Manual
Mini Touch Panels
Version 03

User Manual Mini Touch Panels
UM002_03, 13.03.2001
Copyright © CUE, s.r.o. Praha, Czech Republic 1990 - 2001.
All rights reserved. Specifications are subject to change without prior notice.

User Manual Mini Touch Panels
www.cue.cz
Page 3 of 30
Table of Contents
1. Introduction....................................................................................................................................... 4
1.1. Overview ................................................................................................................................................... 4
1.2. Models....................................................................................................................................................... 4
1.3. Features.................................................................................................................................................... 4
2. Mounting the Mini Touch Panels.................................................................................................... 5
2.1. Desktop Models......................................................................................................................................... 5
2.2. Table Built-in Model................................................................................................................................... 6
2.3. Wall Mounted Model.................................................................................................................................. 7
2.4. Rack-mount Model .................................................................................................................................... 7
3. Cleaning the Mini Touch Panels..................................................................................................... 8
4. Connecting the Wired Models......................................................................................................... 9
4.1. Overview ................................................................................................................................................... 9
4.2. Desktop and Table Built-in Models............................................................................................................ 9
4.3. Wall Mounted Model.................................................................................................................................. 9
4.4. Connection to the Assistant or Assistant-S.............................................................................................. 10
4.5. Multiple Mini Touch Panels in a RS-485 Bus Installation......................................................................... 10
4.6. Connection for Service Functions............................................................................................................ 10
5. Using and Connecting the Wireless RF Model............................................................................ 11
5.1. Overview ................................................................................................................................................. 11
5.2. Power Switch........................................................................................................................................... 12
5.3. Charging.................................................................................................................................................. 12
5.4. Connection for Service Functions............................................................................................................ 13
6. Setting the Display Contrast......................................................................................................... 14
7. CUEshell Description..................................................................................................................... 15
7.1. Overview ................................................................................................................................................. 15
7.2. Main Screen............................................................................................................................................ 15
7.3. System Functions Screen........................................................................................................................ 16
8. Loader Description......................................................................................................................... 19
8.1. Overview ................................................................................................................................................. 19
8.2. Loader Functions..................................................................................................................................... 19
9. Troubleshooting............................................................................................................................. 22
10.Specifications ................................................................................................................................. 23
10.1. General.............................................................................................................................................. 23
10.2. Desktop Model touchCUE-S.............................................................................................................. 23
10.3. Desktop Model touchCUE-S 99......................................................................................................... 23
10.4. Table Built-in Model........................................................................................................................... 23
10.5. Wall Mounted Model.......................................................................................................................... 24
10.6. Rack-mount Model............................................................................................................................. 24
10.7. Wireless RF Model ............................................................................................................................ 24
11.Mechanical Drawings..................................................................................................................... 25
11.1. Model touchCUE-S and touchCUE-SRF .......................................................................................... 25
11.2. Desktop Model touchCUE-S 99......................................................................................................... 26
11.3. Table Built-in Model........................................................................................................................... 27
11.4. Wall Mounted Model.......................................................................................................................... 28
11.5. Rack-mount Model............................................................................................................................. 29

User Manual Mini Touch Panels
www.cue.cz
Page 4 of 30
1. Introduction
1.1. Overview.........................................................................................
The mini touch panel is a stand-alone device with 6” color LCD flat screen, which displays control
buttons with a description. The requested function is selected using a finger touch of a button on the
screen. Its most important advantage is a display of only the buttons that are needed at a time.
All mini touch panel models are full compatible with Cue control units. All AV equipment, entire
environment including lights, projection screens, window blinds, air-conditioning etc. can be controlled
by just a touch of a finger. Each individual screen button is associated with sequences stored in a
control unit.
User application screen layouts containing buttons, bargraphs, logos, drawings etc. are prepared on
PC and downloaded into the touch panel. The user application can be developed using Cue Design
Director.
1.2. Models ............................................................................................
Model Product code Description
touchCUE-S CS0142 Wired desktop model in plastic enclosure.
touchCUE-S 99 CS0157 Wired desktop model in wood enclosure.
touchCUE-S /t CS0143 Wired table built-in model.
touchCUE-S /w CS0158 Wired wall mounted model.
touchCUE-S /r CS0144 Wired 19” rack-mount model.
touchCUE-SRF CS0177 Wireless RF hand-held or desktop model in plastic enclosure.
1.3. Features..........................................................................................
The main features of the mini touch panels are
•5.8” diagonal color CSTN LCD display, 16 colors
•Screen resolution 320 x 240 pixels
•High resolution analog resistive touch panel
•Connection RS-485 or wireless RF communication

User Manual Mini Touch Panels
www.cue.cz
Page 5 of 30
2. Mounting the Mini Touch Panels
2.1. Desktop Models..............................................................................
2.1.1. Overview
Desktop models can be placed on any flat surface. Don’t forget to prepare rightful bushing for the
cable incl. standard connector. Minimum diameter of the bushing for Sub-D, 9-pin, male connector is
35 mm.
2.1.2. Screen Angle Adjusting
Adjust screen angle from 0oto 70oby hand (see pictures).
max. 10 N
0
o
to 70
o
touchCUE-S or touchCUE-SRF side view
0oto 70o
max. 10 N
touchCUE-S 99 side view
In case you are not satisfied with display mechanism toughness, change carefully toughness using
Imbus screw driver 4 mm. The toughness setting screw is located on the bottom panel of touchCUE-S
or on the back side of touchCUE-S 99 (see pictures). Power for screen angle adjusting can be max. 10
N measured on the top edge of display part. If you set higher toughness, you can damage the display
mechanism.
Toughness setting
Imbus screw 4 mm
touchCUE-S or touchCUE-SRF bottom view
Toughness setting
Imbus screw 4 mm
touchCUE-S 99 bottom view

User Manual Mini Touch Panels
www.cue.cz
Page 6 of 30
2.2. Table Built-in Model.......................................................................
Steps are
1. Cut out the surface using dimensions shown in figure below.
2. Place the touch panel into the cutout.
3. Fix two fixing holders to touch panel case by using four shorter screws.
4. Fix the touch panel to surface bottom side by using two longer screws.
46 mm
Free space for cables and cooling
67 mm
Fixing holder
192 mm
127 mm
Cut out
132 mm
210 mm
Minimal space for panel

User Manual Mini Touch Panels
www.cue.cz
Page 7 of 30
2.3. Wall Mounted Model ......................................................................
A wall mounted model allows to install a mini touch panel to the wall. A recommended distance from
the floor is 1 500 mm. The wall mounted model has two parts - the built-in case and the front panel
with the display.
In advance of the mini touch panel installation only the built-in case must be installed into the wall.
Steps are
1. Prepare the necessary space in the wall. Space dimensions are approx. width 230 mm, height 140
mm and depth 80 mm.
2. Insert the built-in case into the prepared space and fix the right position using the standard wall or
plaster material.
Very important note: the position must be with ±
±±
±0.0Otolerance in horizontal level and the
front side of the wall built-in case must be on equal level with the surface of the plaster.
Now you can install the front panel with the display. Steps are
1. Insert the front panel into the built-in case.
2. Line up the top right and bottom left screws, then line up the bottom right and top left screws.
3. Tighten all the screws.
95 mm
35.5 mm
Built-in case
Front panel
with display
Panel screws
Hole for the cable
Wall Wall Plaster
Built-in case
20 mm
Cable channel in the wall
Recommended
1 500 mm from the floor
2.4. Rack-mount Model.........................................................................
Steps are
1. Insert the touch panel into the 19” rack. Necessary rack space is 3 units.
2. Line up the top right and bottom left screws, then line up the bottom right and top left screws.
3. Tighten all the screws.

User Manual Mini Touch Panels
www.cue.cz
Page 8 of 30
3. Cleaning the Mini Touch Panels
You should clean the mini touch panel screen overlay after each day’s use.
Materials required are
1. Two clean, soft texture cloths (cotton).
2. Spray bottle of cleaning solution without alcohol (window cleaner).
3. Stainless steel parts of mini touch panels should be cleaned using special cleaning solution, for
example 3M Stainless Steel Cleaner & Polish, SS9100 2648 3.
Steps are
1. Turn the mini touch panel off.
2. Spray a small amount of the cleaning solution onto one of the cloths.
3. Clean the mini touch panel overlay with the damp cloth.
4. Wipe the mini touch panel overlay with the dry cloth.

User Manual Mini Touch Panels
www.cue.cz
Page 9 of 30
4. Connecting the Wired Models
4.1. Overview.........................................................................................
A wired mini touch panel uses a connector or a screw terminal for data (RS-485) and power supply.
Using this connector or terminal the panels can be connected to
1. Assistant or Assistant-S using a Control Panel Cable 485 or user made cable.
2. RS-485 bus installation. For more details see RS-485 Connection User Manual.
The power consumption of the mini touch panel is max. 0.4 A. Up to four mini touch panels can be
powered from the Assistant or Assistant-S, for more touch panels power supply see RS-485
Connection User Manual.
After switching the power supply off a minimum pause of 5 seconds is necessary before switching the
power supply of the touch panel unit on again.
4.2. Desktop and Table Built-in Models...............................................
Desktop and table built-in models use a standard cable 3 m length with Sub-D, 9-pin, male connector
for data and power. Connect the Sub-D, 9-pin connector to the system and fix it firmly with the screws
on the plug.
1 5
6 9
Sub-D, 9 pin, male connector pinouts
Pin 1: ground
Pin 2: - B (RS-485 signal)
Pin 3: + A (RS-485 signal)
Pin 4: not used
Pin 5: ground
Pin 6: not used
Pin 7: not used
Pin 8: not used
Pin 9: power supply + 24 VDC
4.3. Wall Mounted Model ......................................................................
A wall mounted model uses a screw terminal located on the back side of the front panel part. An user
made cable is necessary for a connection to the system.
1234 4 pin screw terminal pinouts
Pin 1: power supply + 24 VDC
Pin 2: + A (RS-485 signal)
Pin 3: - B (RS-485 signal)
Pin 4: ground

User Manual Mini Touch Panels
www.cue.cz
Page 10 of 30
4.4. Connection to the Assistant or Assistant-S.................................
Control Panel Cable RS-485
1 432
OUT RS-485INE
Assistant or Assistant-S
4.5. Multiple Mini Touch Panels in a RS-485 Bus Installation............
OUT RS-485INE
Assistant or Assistant-S
1 432
User made cable
4.6. Connection for Service Functions................................................
There must be connection between mini touch panel and Assistant or Assistant-S described above.
Your PC serial port must be connected to the HOST COMPUTER connector on the Assistant or
Assistant-S using the Control Cable 9-pin.
HOSTCOMPUTER MEMORY CARD PCMCIA STANDARD IR SERIAL I/O ANALOG GENERAL I/O
TEST RESETDATA OPT.
POWERAUXILIARY
1 3 42 1 3 42 5 7 86 9 10 11 12 13 14 15 16 +12 -12 +55 7 86 9 1 3 42 1 3 42 5 7 86
Control Cable 9-pin

User Manual Mini Touch Panels
www.cue.cz
Page 11 of 30
5. Using and Connecting the Wireless RF Model
5.1. Overview.........................................................................................
The wireless RF model touchCUE-SRF uses a radio frequency communication and must be used with
a base unit rfbaseCUE. The base unit links the RF communication to the RS-485 bus. More details
about using and connecting of the rfbaseCUE see in the User Manual rfbaseCUE.
touchCUE-SRF
rfbaseCUE
+ - A B
RS 485
1 A
POWER
DATA
rfbaseCUE
B-
A+
Ground
+ 24 VDC
1 432
RS-485 bus connection

User Manual Mini Touch Panels
www.cue.cz
Page 12 of 30
5.2. Power Switch..................................................................................
The power switch is located on the bottom side of touchCUE-SRF.
Power switch
OFF
ON
touchCUE-SRF
bottom view
5.3. Charging.........................................................................................
The CUEcharger-F must be used for charging. Connect the CUEcharger-F to the touchCUE-SRF
using a RJ-12 cable. The connector RJ-12 is located on the bottom side of the touchCUE-SRF.
Charging time is max. 2 hours. Fast charging is automatically terminated after reaching full capacity
and red LED labeled CHARGE on the CUEcharger-F will switch off.
Power switch
Connector RJ-12
OFF
ON CHARGE POWER
touchCUE-SRF
bottom view
CUEcharger-F
RJ-12 cable
230 VAC socket

User Manual Mini Touch Panels
www.cue.cz
Page 13 of 30
5.4. Connection for Service Functions................................................
Your PC serial port must be connected to the RJ-12 connector using the touchCUE-SRF to PC cable
adapter. This adapter allows to connect the CUEcharger-F at the same time.
touchCUE-SRF to PC
cable adapter
Power switch
Connector RJ-12
OFF
ON CHARGE POWER
touchCUE-SRF
bottom view
CUEcharger-F
Sub-D, 9-pin male to female cable
RJ-12 cableRJ-12 cable
230 VAC socket

User Manual Mini Touch Panels
www.cue.cz
Page 14 of 30
6. Setting the Display Contrast
All mini touch panel models allow to set a LCD display contrast.
All desktop models have two contrast buttons on the right side of the movable display part. Table
built-in model, wall mounted model and 19” rack mount model have two contrast buttons on the front
panel. See picture.
By keeping the CONTRAST UP button, the display contrast is increasing. By keeping the CONTRAST
DOWN button, the display contrast is decreasing.
CONTRAST UP
CONTRAST DOWN
CONTRAST UP
CONTRAST DOWN
CONTRAST UP
CONTRAST DOWN
Model touchCUE-S and touchCUE-SRF Desktop model touchCUE-S 99
Table built-in model
CONTRAST UP
CONTRAST DOWN
CONTRAST UP
CONTRAST DOWN
Wall mounted model
19" rack-mount model

User Manual Mini Touch Panels
www.cue.cz
Page 15 of 30
7. CUEshell Description
7.1. Overview.........................................................................................
This description is valid for firmware versions as described in the following table.
Model Design Director 2.x Design Director 3.x
All wired models Firmware version 1.11 or higher Firmware version 3.01 or higher
Wireless model touchCUE-SRF Not supported Firmware version 3.01 or higher
The CUEshell is a system software that allows an user access to mini touch panel basic system
functions. When the system functions are not requested the CUEshell loads and starts an user
application.
The CUEshell can start the user layout description (*.wdf) created with Cue Design Director.
If an error occurs during the system starting the system opens its System Functions Screen and the
error message is displayed.
7.2. Main Screen....................................................................................
When the mini touch panel is switched on the Main Screen of the CUEshell is displayed.
This screen displays the system version and loads an user application after about 5 seconds.
If the screen is touched anywhere during this period the user application isn’t started and the System
Functions Screen or Password Screen is displayed. The Password screen asks you to enter password
to enter the System Functions Screen – details see below, OPERATOR – SETTINGS – Shell Protect
Enter Password to display CUEshell
0CUEshell
789
456
123
RUN

User Manual Mini Touch Panels
www.cue.cz
Page 16 of 30
7.3. System Functions Screen .............................................................
CUEshell
OPERATOR
CALIBRATE
DOWNLOAD
RUN
When the Main Screen is touched anywhere the user application is not started and the System
Function Screen is displayed.
•Button RUN starts the user application.
•Button CALIBRATE activates calibration of the mini touch panel display.
•Button DOWNLOAD starts change of the user application.
•Button OPERATOR enters the system page Operator.
7.3.1. Starting User Application
The button RUN starts the user application. If an error occurs during loading of the application the
error message is displayed and the screen remains active.
7.3.2. Calibrating
The button CALIBRATE is disabled at this time. Please use CALIBRATE button from the Loader as
described above.
7.3.3. Downloading User Application
To download a new user layout application connect mini touch panel as described in the section
Connection for Service Functions.
Steps are
1. Enter System Function Screen of CUEshell.
2. Press button DOWNLOAD. Download of Layout screen is displayed.
Important warning
Before pressing the button DOWNLOAD, make sure you have the layout file (*.wdf) on your PC.
If you do not download any application, you will lose the current layout application.
3. Press button DOWNLOAD.
4. Select Tools - Download touchCUE in Cue Design Director or in Cue Programming Director
software. The PC displays Open File dialog.
5. Browse user application and click Open button to start transfer. The PC displays Download File
dialog with information about download process.
6. After end of download the System Functions Screen is displayed on the mini touch panel.
7. Press RUN button to start new user application.

User Manual Mini Touch Panels
www.cue.cz
Page 17 of 30
Notes
•It is possible to download user application up to 2MB.
•It is possible to discard download by pressing the button CANCEL on PC or on mini touch panel.
7.3.4. Operator Functions
The button OPERATOR displays the screen Operator.
O P E R A T O R
0EXIT
789
456
123
SERVICE
SETTINGS
CALIBRATE
SETTINGS
The button SETTINGS displays a new screen with following functions. The password is "1234".
S E T T I N G S
OK
- 1 +
Shell Protect On Clock . . .
Cancel
About . . .
Unit Address
- 0 +
ScrSaver [min]
•Shell protect
This button allows you to lock all shell function by password to avoid unauthorized erasing of
firmware, user application or touch panel calibration values. If you set Shell Protect “On”, the
message “WARNING – CUEshell will be protected” is displayed for a moment before exit
SETTINGS screen (OK button). This message gives you the chance to return to SETTINGS
screen without Shell Protect password.
The Shell Protect password is part of firmware so cannot be changed by user. It is set to
"41433553".
•Unit Address
It is used for display and change of the unit address. When you use more panels connected to
control unit you must set a different unit address for each panel.
You can set an address from 1 to 9.
•ScrSaver [min]
This function displays and changes the delay of the system screen and a back light saver.
You can enter delay from 1 to 90 minutes. When you set delay to 0 the screen saver is disabled.

User Manual Mini Touch Panels
www.cue.cz
Page 18 of 30
•Clock
This button is disabled at this time. In the future version of mini touch panel it will be possible to
correct the system clock and date.
•About
This button displays the system software version, the touchAPI version number and the control
unit firmware version if present.
•Cancel
This button discards all changes and enables return to the Operator Screen.
•OK
This button saves all changes and enables return to the Operator Screen.
CALIBRATE
The button CALIBRATE allows to access to the calibration test of the touch screen. No password is
required.
SERVICE
The button SERVICE enters the service mode. The password is "61214118". This mode is for qualified
service people only.

User Manual Mini Touch Panels
www.cue.cz
Page 19 of 30
8. Loader Description
8.1. Overview.........................................................................................
The Loader is a system software that allows an user access to mini touch panel basic system
functions. After power on the mini touch panel loader version is displayed and after approx. 1 second,
the system starts.
8.2. Loader Functions...........................................................................
To access the loader functions
1. Switch panel off.
2. Press and hold the touch sensor in the center.
3. Switch panel on.
4. Release the finger after loader functions screen or Password screen is displayed.
The Password screen asks you for the password if Shell Protect is set “On” - details see above,
OPERATOR – SETTINGS – Shell Protect
123
789
456
Enter Password or 1111 to continue
If you enter the proper password, following screen will be displayed.
NEW FIRMWARE DOWNLOAD
CALIBRATE RUN
•Button NEW FIRMWARE starts change of the system firmware.
•Button DOWNLOAD starts change of the user application.
•Button CALIBRATE activates calibration of the mini touch panel.
•Button RUN starts the system.

User Manual Mini Touch Panels
www.cue.cz
Page 20 of 30
8.2.1. Downloading New Firmware
To download a new firmware connect mini touch panel as described in the section Connection for
Service Functions. After that activate the loader functions screen as described above and press the
button NEW FIRMWARE. New screen is displayed.
EXIT
ERASE CODE FLASH AND CONTINUE
Press the button EXIT to return to the loader functions screen.
Important warning
Before pressing the button ERASE CODE FLASH AND CONTINUE, make sure you have firmware file
(*.bin) on your PC.
If you do not download any firmware, you will lose the functionality of the panel.
If you have firmware file (*.bin) on your PC, press button ERASE CODE FLASH AND CONTINUE to
download new firmware.
Actual firmware version is a part of Cue Director software (version 2.01a or higher) and it is available
on Cue’s web site (www.cue.cz). After erasing Code Flash Memory, the panel asks for data. Please
start Cue Design Director or Cue Programming Director, select menu Tools-Download touchCUE and
browse appropriate *.bin file. After downloading new firmware the panel returns to the loader functions
screen.
8.2.2. Downloading User Application
To download a new user layout application connect mini touch panel as described in the section
Connection for Service Functions. After that activate the loader functions screen as described above
and press the button DOWNLOAD. New screen is displayed.
DOWNLOAD
EXIT
Download of Layout
This manual suits for next models
11
Table of contents