DAAB DB407 User manual

For automatic control unit DAAB EP104
with software version 4.07
INSTRUCTION MANUAL
DAAB OUTPUT CARD DB407
FAAC Nordic AB
www.faac.se
Revision: 11

2
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
2
Technical data
Dimensions (WxHxD) 44x90x24 mm
Temperature range 0 to 50°C
Indications 6x LEDs
Outputs 1x triac output 0.75A, 24-230VAC
5x relay outputs max 6A resistive load per relay output at 230VAC or 2A
at 24VDC
Degree of protection e circuit board is intended for internal installation in an enclosure
Safety instructions
See operating manual for automatic control unit EP104.
General description
Add-in card to obtain 6x outputs on EP104. All the outputs have programmable function. Output functions are set on
EP104.
If output o4 is used, the supply voltage must be of AC type, alternating current, as this output is of the triac type. Note that
i2 is common to o3 and o4.
e status of the outputs indicated by LEDs installed at the top of the card. A lit LED indicates closed function.
Installation
1. Discharge any static charge in your body by touching an earthed connection before starting installation.
2. Disconnect power to EP104
3. Screw the DB407 board into place on the spacers on the EP104 using two M4x6 screws.
4. Connect cable to "OUTPUT" cable.
5. Connect the board as described in Connection.
Contact for
connection of DB407

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
3
Connection
If extra low voltage is used together with low voltage, cables connected to groups i1, o1, o2 and i2, o3, o4 and i3, o5, o6
must be secured with cable ties as close to the terminal as possible.
Connection must be performed by a qualied electrician.
}
L/+
N/-
o1 o2 i1 o3 o4 i2 o5 o6 i3
i1 i2 i3
}
}
L/+
N/-
L/+
N/-
230VAC/24VDC
NB AC only if o4 is used
230VAC/24VDC
230VAC/24VDC
DB407
If o4 is used for AC and o3 is to be used for DC, o3 can control an interposing relay
When the board has been installed and connected, the power supply to EP104 can be switched
on.

4
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
4
Functions using add-in card DB407
With DB410 installed there is access to ve programmable relay outputs and one triac output. ese outputs are grouped
into three groups with two common positions. Note that the positions located closest to the printed circuit board on each
terminal are the common positions. ese positions are marked i1, i2 and i3. e outputs are the upper terminal positions.
Functions of programmable outputs 1 - 6
e instructions are identical for all six programmable outputs, apart from the channel number – output 1 has
channel number o1nn, output 2 has channel number o2nn, etc. e settings below are for output 1.
Activate programmable output 1 by setting o100 to the desired function. A value of 0 means that the output is
disabled (open) regardless of the settings of other channels.
If you set the value to 1, the output can be used as a trac light signal based on the position indication. Movement
and warning time signals are also available with this setting. e value 2 is for presence detection in the vehicle loop,
the value 3 is for motor locks, and the value four turns the output into an alarm output.
Channel o110 Open position
Set to 1 for a constant signal in the open position.
Channel o111 Mid position
Set 1 to obtain constant signal in mid position.
Channel o112 Closed position
Set 1 to obtain constant signal in closed position.
Example for a green light: o110 = 1, o111 = 0, o112 = 0.
Example for a red light: o110 = 0, o111 = 1, o112 = 1.
Channel o113 Movement
Use this channel to specify function during movement. e function will be active as soon as the door starts moving.
See the channel reference for the available options. Only output 4 is able to send a ashing signal.
Channel o120 Warning time before start
Settable time 0.00 – 9.59 minutes, where 0.0 means closed. Which function is to be warned is selected in o121.
Channel o121 Warning function in combination with channel o120
Set value 1 to obtain constant signal before automatic close, 2 to obtain constant signal before park and automatic
close, 3 to obtain constant signal before close signal, park and automatic close, 4 for signal before all control signals.
Channel o122 Function during warning
Select 1 if the output signal is to be disabled during storing in any output.
Select 2 if the output is to continue to indicate position or movement regardless of warning.
Channel o130 Delay for alarms specied in o131 and o132. e alarm is delayed by the set time of 0.00 – 9.59
minutes. e factory setting is 0.00.
Channel o131-o142 Alarm in dierent conditions
If it is set to 1, the output gives a signal when the condition, according to the channel specication, has been fullled
for longer than the time set in o130.
Select the output to be normally open or normally closed by setting channel o183 to:
e value 1 is for normally open (NO) and the value 2 is for normally closed (NC).
Channel o191 Function when LOOP1, LOOP2 or PHOTO are activated:
Used to set the presence detection required from the vehicle loop. See the channel reference for the available options.
Function of programmable output 4
In principle, programmable output 4 is the same as outputs 1, 2, 3, 5 and 6, except that it is a triac output. e settings
are the same for outputs 1 to 6, except that the alternative for ashing signal only exists for output 4. See the channel
reference for the channel settings.

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
5
• Fence alarm
Outputs o1 or 2 are available for fence alarms. Note that i1+i1 are two common inputs for o1 and o2. If there is a
voltage drop, these outputs are open, NO. Remember that the outputs must be connected so that the fence alarm is
activated if a cable is detached, there is a break in a cable or the EP104 loses its power supply. Specify the following
settings to use output 1 for fence alarm.
o100 = 1, Position indication.
o110 = 1, Signal in open position.
o111 = 1, Signal in mid position.
o113 = 3, Signal in opening/closing movement.
o114 = Delay in switch-o, at least 1 second according to alarm manufacturer's instructions.
o120 = Warning test before start, according to the alarm manufacturer's instructions.
o121 = 4, Constant signal before all movements.
o122 = 2, Output signal as congured in o110-o113.

6
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
6
• Channel list, o-channels
Programmable output 1
No. Name Range Factory Setting
o100 Function of output 1 0 - 4 1
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o110 – o122
2 Presence detection/Direction sensing. Signal as congured in o191
3Lock
4 Alarm output Signal as congured in o130 – o142
o110 Open position 0 - 1 1
0 Disabled
1 Constant signal
o111 Mid position 0 - 1 0
0 Disabled
1 Constant signal
o112 Closed position 0 - 1 0
0 Disabled
1 Constant signal
o113 Movement 0 - 4 4
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o110, o111 and o112.
o114 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o120 Warning time before start 0.00-9.59 minutes 0.00
o121 Warning function in combination with o120 1 - 4 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
o122 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Output signal as congured in o110-o113

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
7
No. Name Range Factory Setting
o130* Alarm if there is an error as congured in o131-o139. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o131* Alarm for faulty safety edge. Time as in o130. 0 - 1 0
0 Disabled
1 Constant signal
o132* Alarm for critical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o133* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o134* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o135* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o136* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o137* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o138* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o139* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o142* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o183 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o100 is set to 4.

8
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
8
o191 Function when LOOP2, LOOP2 or PHOTO
activated
01 - 14 01
01 Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02 Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03 Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either
LOOP1 or LOOP2 is clear.
04 Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05 Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO
or LOOP1 is clear.
06 Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO
or LOOP2 is clear.
07 Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08 Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either
LOOP1 or LOOP2 is clear.
09 Direction sensing Signal when rst LOOP1 and then LOOP2 are activated. e signal remains
until LOOP2 is clear.
10 Direction sensing Signal when rst LOOP1 and then PHOTO are activated. e signal remains
until PHOTO is clear.
11 Direction sensing Signal when rst LOOP2 and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
12 Direction sensing Signal when rst LOOP2 and then PHOTO are activated. e signal remains
until PHOTO is clear.
13 Direction sensing Signal when rst PHOTO and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
14 Direction sensing Signal when rst PHOTO and then LOOP2 are activated. e signal remains
until LOOP2 is clear.

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
9
Programmable output 2
No. Name Range Factory Setting
o200 Function of output 2 0 - 4 1
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o210 – o222
2 Presence detection/Direction sensing. Signal as congured in o291
3Lock
4 Alarm output Signal as congured in o230 – o242
o210 Open position 0 - 1 0
0 Disabled
1 Constant signal
o211 Mid position 0 - 1 0
0 Disabled
1 Constant signal
o212 Closed position 0 - 1 1
0 Disabled
1 Constant signal
o213 Movement 0 - 4 4
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o210, o211 and o212.
o214 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o220 Warning time before start 0.00-9.59 minutes 0.00
o221 Warning function in combination with o220 1 - 4 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
o222 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Output signal as congured in o210-o213

10
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
10
No. Name Range Factory Setting
o230* Alarm if there is an error as congured in o231-o239. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o231* Alarm for faulty safety edge. Time as in o230. 0 - 1 0
0 Constant signal
1Active
o232* Alarm for uncritical error message in display 0 - 1 0
0 Constant signal
1Active
o233* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o234* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o235* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o236* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o237* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o238* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o239* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o242* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o283 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o200 is set to 4.

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
11
o291 Function when SL.1, SL.2 or photocell/loop activated 01 - 14 01
01 Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02 Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03 Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either LOOP1
or LOOP2 is clear.
04 Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05 Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO or
LOOP1 is clear.
06 Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO or
LOOP2 is clear.
07 Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08 Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either LOOP1
or LOOP2 is clear.
09 Direction sensing Signal when rst LOOP1 and then LOOP2 are activated. e signal remains until
LOOP2 is clear.
10 Direction sensing Signal when rst LOOP1 and then PHOTO are activated. e signal remains
until PHOTO is clear.
11 Direction sensing Signal when rst LOOP2 and then LOOP1 are activated. e signal remains until
LOOP1 is clear.
12 Direction sensing Signal when rst LOOP2 and then PHOTO are activated. e signal remains
until PHOTO is clear.
13 Direction sensing Signal when rst PHOTO and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
14 Direction sensing Signal when rst PHOTO and then LOOP2 are activated. e signal remains
until LOOP2 is clear.

12
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
12
Programmable output 3
No. Name Range Factory Setting
o300 Function of output 3 0 - 4 1
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o310 – o322
2 Presence detection/Direction sensing. Signal as congured in o391
3Lock
4 Alarm output Signal as congured in o330 – o342
o310 Open position 0 - 1 1
0 Disabled
1 Constant signal
o311 Mid position 0 - 1 0
0 Disabled
1 Constant signal
o312 Closed position 0 - 1 0
0 Disabled
1 Constant signal
o313 Movement 0 - 4 4
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o310, o311 and o312.
o314 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o320 Warning time before start 0.00-9.59 minutes 0.00
o321 Warning function in combination with o320 1 - 4 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
o322 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Signal as congured in o310-o313

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
13
No. Name Range Factory Setting
o330* Alarm if there is an error as congured in o331-o339. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o331* Alarm for faulty safety edge. Time as in o330. 0 - 1 0
0 Disabled
1 Constant signal
o332* Alarm for critical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o333* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o334* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o335* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o336* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o337* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o338* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o339* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o342* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o383 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o300 is set to 4.

14
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
14
o391 Function when SL.1, SL.2 or photocell/loop activated 01 - 14 01
01 Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02 Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03 Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either LOOP1
or LOOP2 is clear.
04 Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05 Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO or
LOOP1 is clear.
06 Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO or
LOOP2 is clear.
07 Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08 Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either LOOP1
or LOOP2 is clear.
09 Direction sensing Signal when rst LOOP1 and then LOOP2 are activated. e signal remains until
LOOP2 is clear.
10 Direction sensing Signal when rst LOOP1 and then PHOTO are activated. e signal remains
until PHOTO is clear.
11 Direction sensing Signal when rst LOOP2 and then LOOP1 are activated. e signal remains until
LOOP1 is clear.
12 Direction sensing Signal when rst LOOP2 and then PHOTO are activated. e signal remains
until PHOTO is clear.
13 Direction sensing Signal when rst PHOTO and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
14 Direction sensing Signal when rst PHOTO and then LOOP2 are activated. e signal remains
until LOOP2 is clear.

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
15
Programmable output 4
No. Name Range Factory Setting
o400 Function of output 4 0 - 4 0
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o410 – o422
2 Presence detection/Direction sensing. Signal as congured in o491
3Lock
4 Alarm output Signal as congured in o430 – o442
o410 Open position 0 - 2 0
0 Disabled
1 Constant signal
2 Flashing signal
o411 Mid position 0 - 2 1
0 Disabled
1 Constant signal
2 Flashing signal
o412 Closed position 0 - 2 1
0 Disabled
1 Constant signal
2 Flashing signal
o413 Movement 0 - 7 0
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o410, o411 and o412.
5 Flashing signal in the opening movement
6 Flashing signal in the closing movement
7 Flashing signal in the opening and closing movement
o414 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o420 Warning time before start 0.00-9.59 minutes 0.00
o421 Warning function in combination with o420 1 - 8 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
5 Flashing signal before automatic closing
6 Flashing signal before park and automatic closing
7 Flashing signal before close signal, park and automatic closing
8 Flashing signal before all signals

16
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
16
No. Name Range Factory Setting
o422 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Output signal as congured in o410-o413
o423 Flashing frequency 0.1-2.0 seconds 0.5
o430* Alarm if there is an error as congured in o431-o439. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o431* Alarm for faulty safety edge. Time as in o430. 0 - 1 0
0 Constant signal
1Active
o432* Alarm for critical error message in display 0 - 1 0
0 Constant signal
1Active
o433* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o434* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o435* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o436* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o437* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o438* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o439* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o442* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o483 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o400 is set to 4.

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
17
o491 Function when LOOP2, LOOP2 or PHOTO activated 01 - 14 01
01 Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02 Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03 Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either LOOP1
or LOOP2 is clear.
04 Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05 Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO or
LOOP1 is clear.
06 Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO or
LOOP2 is clear.
07 Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08 Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either LOOP1
or LOOP2 is clear.
09 Direction sensing Signal when rst LOOP1 and then LOOP2 are activated. e signal remains until
LOOP2 is clear.
10 Direction sensing Signal when rst LOOP1 and then PHOTO are activated. e signal remains
until PHOTO is clear.
11 Direction sensing Signal when rst LOOP2 and then LOOP1 are activated. e signal remains until
LOOP1 is clear.
12 Direction sensing Signal when rst LOOP2 and then PHOTO are activated. e signal remains
until PHOTO is clear.
13 Direction sensing Signal when rst PHOTO and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
14 Direction sensing Signal when rst PHOTO and then LOOP2 are activated. e signal remains
until LOOP2 is clear.

18
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
18
Programmable output 5
No. Name Range Factory Setting
o500 Function of output 1 0 - 4 0
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o510 – o522
2 Presence detection/Direction sensing. Signal as congured in o591
3Lock
4 Alarm output Signal as congured in o530 – o542
o510 Open position 0 - 1 0
0 Disabled
1 Constant signal
o511 Mid position 0 - 1 0
0 Disabled
1 Constant signal
o512 Closed position 0 - 1 0
0 Disabled
1 Constant signal
o513 Movement 0 - 4 4
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o510, o511 and o512.
o514 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o520 Warning time before start 0.00-9.59 minutes 0.00
o521 Warning function in combination with o520 1 - 4 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
o522 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Output signal as congured in o510-o513

DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
19
No. Name Range Factory Setting
o530* Alarm if there is an error as congured in o531-o539. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o531* Alarm for faulty safety edge. Time as in o530. 0 - 1 0
0 Disabled
1 Constant signal
o532* Alarm for critical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o533* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o534* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o535* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o536* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o537* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o538* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o539* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o542* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o583 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o500 is set to 4.

20
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
20
o591 Function when LOOP2, LOOP2 or PHOTO activated 01 - 14 01
01 Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02 Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03 Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either
LOOP1 or LOOP2 is clear.
04 Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05 Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO
or LOOP1 is clear.
06 Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO
or LOOP2 is clear.
07 Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08 Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either
LOOP1 or LOOP2 is clear.
09 Direction sensing Signal when rst LOOP1 and then LOOP2 are activated. e signal remains
until LOOP2 is clear.
10 Direction sensing Signal when rst LOOP1 and then PHOTO are activated. e signal remains
until PHOTO is clear.
11 Direction sensing Signal when rst LOOP2 and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
12 Direction sensing Signal when rst LOOP2 and then PHOTO are activated. e signal remains
until PHOTO is clear.
13 Direction sensing Signal when rst PHOTO and then LOOP1 are activated. e signal remains
until LOOP1 is clear.
14 Direction sensing Signal when rst PHOTO and then LOOP2 are activated. e signal remains
until LOOP2 is clear.
Table of contents
Other DAAB I/O System manuals
Popular I/O System manuals by other brands

ADLINK Technology
ADLINK Technology HSLink HSL-DI32 user guide

Interlogix
Interlogix ITI SuperBus 2000 installation instructions

Janus
Janus C4 I/O Blade installation guide

MG
MG M2BS-8U1 instruction manual

Beijer Electronics
Beijer Electronics G Series quick start guide

Behringer
Behringer Digital Snake S16 quick start guide