DAVI & CIA CS4300C User manual

CS4300C
USER’S MANUAL
MA27-02/B
12/09/2011
www.davicia.com

USER’S MANUAL
MA27-02/B
2
INDEX
Page
1.
1.1.
1. DESCRIP ION
DESCRIP IONDESCRIP ION
DESCRIP ION
3
2.
2.2.
2. INS ALLA ION
INS ALLA IONINS ALLA ION
INS ALLA ION
2.1. Location and setting
2.2. Startup
4
4
4
3.
3.3.
3. OPERA ION
OPERA IONOPERA ION
OPERA ION
3.1. LCD symbol description
3.2. Key functions
3.3. Weighing
3.4. aring
3.5. Hold
3.6. Body Mass Index (BMI)
3.7. Pre- are
5
5
6
6
6
7
7
8
4.
4.4.
4. SE UP
SE UPSE UP
SE UP
4.1. Connecting with PC
4.2. Print function
10
10
11
5.
5.5.
5. MAIN ENANCE
MAIN ENANCEMAIN ENANCE
MAIN ENANCE
AND CLEANING
AND CLEANINGAND CLEANING
AND CLEANING
5.1. Instructions for charge and connect
5.2. Instructions for replacing batteries
5.3. Environmental
5.4. Equipment disposal
12
12
12
12
12
6.
6.6.
6. ROUBLESHOO ING
ROUBLESHOO INGROUBLESHOO ING
ROUBLESHOO ING
13
7.
7.7.
7. ECHNICAL SPECIFICA IO
ECHNICAL SPECIFICA IOECHNICAL SPECIFICA IO
ECHNICAL SPECIFICA IONS
NSNS
NS
14
8.
8.8.
8. WARRAN Y CER IFICA E
WARRAN Y CER IFICA EWARRAN Y CER IFICA E
WARRAN Y CER IFICA E
15
9.
9.9.
9. CE DECLARA ION OF CONFORMI Y
CE DECLARA ION OF CONFORMI YCE DECLARA ION OF CONFORMI Y
CE DECLARA ION OF CONFORMI Y
16

USER’S MANUAL
MA27-02/B
3
1. DESCRIPTION
(1) Gripping handles
(2) Folding arm rests
(3) Seating surface
(4) Locking castors
(5) Foot rests
(6) Display unit at rear
1
2
3
4
5
6

USER’S MANUAL
MA27-02/B
4
2. INSTALLATION
Before putting the device into use, please read with care the information given in the Operating Instructions.
hey contain important instructions for installation, proper use and maintenance of the device.
he manufacturer shall not be liable for damages arising out of failure to heed the following instructions:
o When using electrical components under increased safety requirements, always comply with the appropriate
regulations.
o Improper installation will render the warranty null and void.
o Ensure the voltage marked on the power supply unit, matches your main power supply.
o his device is designed for use indoors.
o Observe the permissible ambient temperatures for use.
o he device meets the requirements for electromagnetic compatibility. Do not exceed the maximum values
specified in the applicable standards.
2.
2.2.
2.1
11
1. LOCA ION AND SE ING
. LOCA ION AND SE ING. LOCA ION AND SE ING
. LOCA ION AND SE ING
We strongly recommend you use this device on flat and hard surface. Any soft surface, like carpet will cause
inaccuracy.
2.
2.2.
2.2
22
2. S AR UP
. S AR UP. S AR UP
. S AR UP
o Connect the equipment to the power supply using the AC adaptor.
o Press the ON/OFF button in the indicator.
o Wait until “0” appears on display.

USER’S MANUAL
MA27-02/B
5
3. OPERATION
Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please
read the following important guidelines:
o Always be sure that the display shows `Zero` before use, if it does not then please press the ZERO key.
o he equipment is designed to detect when a stable weight is achieved, your reading should be taken at this
point.
3.1
3.13.1
3.1.
. .
. LCD SYMBOL DESCRIP ION
LCD SYMBOL DESCRIP IONLCD SYMBOL DESCRIP ION
LCD SYMBOL DESCRIP ION
Display
DisplayDisplay
Display
Description
DescriptionDescription
Description
[→ 0 ←] Zero symbol: If the scale does not show exactly zero value although the scale pan is
unloaded, press the [
[[
[→0
00
0←]
] ]
] key. After a short waiting time, the scale will be zeroed again.
Stable symbol: If the display shows the stabilization display [ο], the scale is in the stable
condition. When the scale is in the unstable condition, the stabilization display [ο]
disappears.
- Minor weight: Weight under zero.
LOW Low Battery: Battery need to change or replace.
BMI
Calculated value of the body mass index (BMI).
HOLD
Hold function / saving function is active.
PRE-TARE
Initially set tare value is active.
NET
he net weight is displayed.
WEIGHT
he present weight value is displayed.
P
RE
-
ARE Indication
kg
NE WEIGH Indication
3
WEIGH Indication
HOLD Indication
Stable symbol
Minor weight
Zero symbol
Low Battery

USER’S MANUAL
MA27-02/B
6
3.2
3.23.2
3.2.
. .
. KEY FUNC IONS
KEY FUNC IONSKEY FUNC IONS
KEY FUNC IONS
Designation
Designation Designation
Designation
Function
Function Function
Function
ON/OFF-switch urn ON/OFF the scale
PRIN button Data transmission via interface(Print-out the results)
BMI button Determine Body Mass Index
HOLD button o hold weighing result on the display / determine stable weighing value
ZERO setting key o reset the display to 0.0kg display / Zero the scale (±2% of full capacity)
M1-5 button o store 5 pre-tare values
PRE- ARE button Setup target weight for tare before weighing
ARE button are weight during weighing process
CLEAR button o clear the wrong entry while entering digits
EN ER-key o confirm the performing functions
Numeric keys Numerical value Entering digits
3.3
3.33.3
3.3.
. .
. WEIGHING
WEIGHINGWEIGHING
WEIGHING
Switch on the scale with the [ON/OFF]
[ON/OFF] [ON/OFF]
[ON/OFF] key. he diagnostic scale self-check is performed and then the software
version is displayed. he scale is ready for weighing when the “0,00 kg
0,00 kg0,00 kg
0,00 kg” weight display is shown.
NO E: If “0,00 kg” won’t display on the screen, press [
[[
[
→
0
00
0
←
]
]]
] key to zero the scale, [
[[
[
→
0
00
0
←
]
] ]
] can be used any time
to zero the scale.
Place a person in the middle of the scale. Wait until the stability display (ο) is shown and then read the weighing
result.
DIREC ION: If a person is heavier than the weighing range, the display will show the “Err” symbol (= overload).
3.4
3.43.4
3.4.
. .
. ARING
ARINGARING
ARING
are allows the user to zero the instrument to cancel the weight of a container/ clothes from the reading of the
instrument, thus giving the true weight of the product/ person being tested.
o urn on the scale using [ON/OFF]
[ON/OFF][ON/OFF]
[ON/OFF] key.

USER’S MANUAL
MA27-02/B
7
o When“0,00 kg
0,00 kg0,00 kg
0,00 kg” displays on the screen and scale beeps twice, place the object (clothes) to be tared on the tray.
o Press [ ARE]
[ ARE][ ARE]
[ ARE] key after the weight stabilizes and stable sign appears on the display.
o Display will return to “0,00 kg
0,00 kg0,00 kg
0,00 kg”
o Place the item/ baby to be weighed (without removing the tare object). he weighing result is the Net weight
of the item / baby.
o o delete the saved tare value, remove the tare object from the tread platform and press [ ARE]
[ ARE][ ARE]
[ ARE] key.
3.5
3.53.5
3.5.
. .
. HOLD
HOLDHOLD
HOLD
he scale is provided with the integrated hold function (determination of average value). It enables people to be
weighed accurately although they are not still on the scale plate.
NO E: Determination of average value is not possible when a person moves too much.
o Switch on the scale with the [ON/OFF]
[ON/OFF][ON/OFF]
[ON/OFF] key. he scale self-check diagnostic is performed. he scale is ready
for weighing when the “0,00 kg
0,00 kg0,00 kg
0,00 kg” weight display is shown.
o Place a person in the centre of the scale plate.
o Press the [HOLD]
[HOLD][HOLD]
[HOLD] key. When the triangle is flashing on the display, the scale takes some measuring values and
then the calculated average value is displayed.
o Remove the object/ baby from the scale platform. he object/ baby’s weight reading will remain on the
display.
o Press the [HOLD]
[HOLD][HOLD]
[HOLD] key again to return the scale to the normal weighing mode.
o HOLD function can be activated before or after putting the weight on the platform. In case of weighing babies
that move a lot, it is recommended to press [HOLD]
[HOLD][HOLD]
[HOLD] key before the person moves on the platform.
3.6
3.63.6
3.6.
. .
. BODY MASS INDEX (BMI)
BODY MASS INDEX (BMI)BODY MASS INDEX (BMI)
BODY MASS INDEX (BMI)
For BMI calculation, height is needed, therefore it is recommended to measure the height of subject before
starting weighing procedure.
o urn ON the scale using [ON/OFF]
[ON/OFF][ON/OFF]
[ON/OFF] key.
o Proceed to weigh as normal.
o After the weight is stable and stable sign displays on the screen press [BMI]
[BMI][BMI]
[BMI] key.
o Display will change to “0,00 kg
0,00 kg0,00 kg
0,00 kg”.
o Key-in the height of the person using numeric keys (0~9). Example: 186cm (the height should be in
centimeters).
o Press [EN ER]
[EN ER][EN ER]
[EN ER] to confirm, the Display will show the B.M.I. of the person.
o Press [BMI]
[BMI][BMI]
[BMI] again to return to normal mode.
Categories of BMI
Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO, 2000 EK IV
and WHO 2004 (WHO - World Health Organization).

USER’S MANUAL
MA27-02/B
8
3.7
3.73.7
3.7.
. .
. PRE
PREPRE
PRE-
--
- ARE
AREARE
ARE
he scale can store 5 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead
Weight or Enter weight using 0~9 keys:
Using Dead Weight
Description
DescriptionDescription
Description
Example
ExampleExample
Example
Press M1-5 key after loading the weight; the display will show blinking m sign.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight. For example:
Press 1 to assign position-1 to preset tare weight.
he display will blink and makea beep sound.
NO E: You can assign any other position (from 1~5) to pre-tare weight.
Enter Weight Using 0-9 Keys
Description
DescriptionDescription
Description
Example
ExampleExample
Example
Press PRE- ARE key, and the extreme left digit will blink.
Enter PRE- ARE weight using 0~9 keys. For example: 10kg
Press EN ER key to confirm the pre-tare weight; the display will show the minus
sign on left of the pre-tare weight value.
Press M1-5 key; the blinking m sign will appear on the display.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight.

USER’S MANUAL
MA27-02/B
9
he instrument will make flash and beep sound and will display the saved Pre-
are Weight.
Recall Pre- are Value:
Description
DescriptionDescription
Description
Ex
ExEx
Example
ampleample
ample
Long press PRE- ARE key for 3 seconds; the display will show the blinking m sign.
Press numeral key 1 ~ 5 to choose pre
Press numeral key 1 ~ 5 to choose prePress numeral key 1 ~ 5 to choose pre
Press numeral key 1 ~ 5 to choose pre-
--
-tare value
tare valuetare value
tare value
Press EN ER key to confirm the pre-tare weight; the instrument will
automatically perform tare function.
Press PRE- ARE key to return to Normal Mode.

USER’S MANUAL
MA27-02/B
10
4. SETUP
Switch ON the scale and long press [ZERO]
[ZERO][ZERO]
[ZERO] key for 3 seconds. First “SE UP” and then “A.OFF” will display
successively.
Auto-off time setup
his enables operator to select the auto turn OFF time of the device.
Auto off time:
Auto off time:Auto off time:
Auto off time: 120 sec/180 sec/240 sec/300 sec/Off
Buzzer on/off setup
his enables operator to select beep sound ON/OFF.
Buzzer:
Buzzer:Buzzer:
Buzzer: On/Off
NO E: o confirm the settings, please press HOLD when “END” displays on the display.
4.1
4.14.1
4.1.
. .
. CONNEC I
CONNEC ICONNEC I
CONNEC ING WI H PC
NG WI H PCNG WI H PC
NG WI H PC
he equipment can be connected to PC to transfer the weighing results.
1. Start Hyper erminal
Start Hyper erminal program from clicking: Start Menu → Programs → Accessories → Communication →
Hyper erminal.
2. New Connection Description
Give new connection a name then click OK.
3. Select Your COM Port
Click Connect to select your COM port. Usually there’s only one option for select. hen click OK.
4. Port Settings
Click Bits per second to set up rate at 9600, Data bits at 8, Parity at None, Stop bits at 1 and Flow control at
Hardware. hen click OK to complete your setting.
5. Output Data
When the patient has been weighed and BMI calculated, simply press the PRIN key to output data from scale
to PC or an Optional Printer.
Parameters of RS232 interface
Set parameters of the scale interface on the connected device. It is not possible to change the scale parameters.
o Baud rate: 9600 bps

USER’S MANUAL
MA27-02/B
11
o Parity check: None
o Data length: 8 bits
o Stop bit: 1 bit
o Handshake: R S/C S
o Data code: ASCII.
4.2
4.24.2
4.2.
. .
. PRIN FUNC ION
PRIN FUNC IONPRIN FUNC ION
PRIN FUNC ION
he Weighing, BMI and Height results can be printed-out for records using RS232 interface cable (included in
accessory kit), which is connected with the round plug at the back terminal.
After weighing and calculating BMI simply press PRIN
PRINPRIN
PRIN key to print out the results.
he format presented below is the standard format of results print-out and cannot be changed.

USER’S MANUAL
MA27-02/B
12
5. MAINTENANCE AND CLEANING
he scale does not require any routine maintenance. However, we recommend checking the scale’s accuracy at
regular intervals. he regularity of these checks is dependent on the level of use and the state of the scale.
o We would recommend using alcohol based wipes or similar when cleaning the scale.
o Please do not use large amounts of water when cleaning the scale as this will cause damage to the scale’s
electronics, you should also refrain from using corrosive liquids or high pressure washers.
o Always disconnect the scale from the main power supply before cleaning.
5.1
5.15.1
5.1.
. .
. INS RUC IONS FOR CHARGE AND CONNEC
INS RUC IONS FOR CHARGE AND CONNECINS RUC IONS FOR CHARGE AND CONNEC
INS RUC IONS FOR CHARGE AND CONNEC
If “Lo” is displayed on the LCD, you should charge scale with AC adaptor.
Locate adaptor plug at the rear of indicator.
Locate adaptor plug at the rear of indicator.Locate adaptor plug at the rear of indicator.
Locate adaptor plug at the rear of indicator.
CAU ION:
Always connect the AC adaptor to the indicator before connecting to the main power supply. Please
disconnect the adaptor from main power supply before indicator.
5.2
5.25.2
5.2.
. .
. INS RUC IONS FOR REPLACING BA ERIES
INS RUC IONS FOR REPLACING BA ERIESINS RUC IONS FOR REPLACING BA ERIES
INS RUC IONS FOR REPLACING BA ERIES
o Remove the battery cover
o ake the battery housing out
o Replace new batteries
o Make sure batteries are well installed
o Reinstall the battery housing
1. Reinstall the battery cover
5.3
5.35.3
5.3.
. .
. ENVIRONMEN AL
ENVIRONMEN ALENVIRONMEN AL
ENVIRONMEN AL
All batteries contain toxic compounds; disposal of batteries should be delegated to a competent organization,
complying with the deposit of Poisonous Waste Regulation 1972.
Please do not incinerate batteries.
he optimum operating temperature for the scale is 5ºC to +35ºC; although it will operate at higher and lower
temperatures the scale’s battery life will adversely be affected.
5.
5.5.
5.4
44
4. EQUIPMEN DISPOSAL
. EQUIPMEN DISPOSAL. EQUIPMEN DISPOSAL
. EQUIPMEN DISPOSAL
All electrical and electronic products should be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the
government or the local authorities.
his crossed-out wheeled bin symbol on the product means the product is covered
by the European Directive 2002/96/EC.
he correct disposal and separate collection of the equipment will help prevent
potential negative consequences for the environment and human health. It is a
precondition for reuse and recycling of used electrical and electronic equipment.

USER’S MANUAL
MA27-02/B
13
6. TROUBLESHOOTING
Error Message
Error MessageError Message
Error Message
Reason
ReasonReason
Reason
Action
ActionAction
Action
Low Battery: his warning shows
that the voltage of battery is too
low to use
Please replace a new battery or plug the AC
adaptor for operation
Overload: he total load exceeds
the maximum capacity of the scale
Please reduce the loading and try again
Counting error (too high): Indicates
that the signal from the load cell is
too high
his error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.
Counting error (too low): Indicates
that the signal from the load cell is
too low
his error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.
Zero count over calibration zero
range +10% while power on
Please recalibrate the instrument
Zero count under calibration zero
range -10% while power on
Please recalibrate the instrument
EEPROM Error: Indicates that
there is a fault with the scale’s
software
his error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.

USER’S MANUAL
MA27-02/B
14
7. TECHNICAL SPECIFICATIONS
Model: CS4300C
Capacity: 300 kg x 100 g
LCD Display: 1.0 inch LCD display with 5 and 1/2 digits
Max. external dimensions: 1100 x 800 x 600 mm
Power supply: AC adapter 15V 300mA / Rechargeable Battery
Key Functions: ON/OFF,ZERO, PRIN , BMI, HOLD, PRE- ARE, ARE, CLEAR, EN ER, 0~9, M1-5
Operation temperature: 5ºC / 35ºC

USER’S MANUAL
MA27-02/B
15
. WARRANTY CERTIFICATE
We provide a 1
11
1-
--
-year
yearyear
year guarantee from the date of purchase. he guarantee covers manufacturing defects or
defects occurring as a result of normal use and operation.
It excludes all removable parts such as batteries, wires, power supply devices, etc. Faults falling within the
guarantee period shall be rectified free of charge upon presentation of the purchase receipt for the appliance. No
other rights can be taken into consideration.
Return shipment is at the customer's expense if the appliance is anywhere other than at the customer's
headquarters.
In the event of damage during shipment, guarantee rights will be granted only if the appliance is shipped in the
original packaging. You are therefore recommended to keep the original packaging.
Following expiry of the guarantee period, all services requested will be dealt with by our specialist technicians at
the user's expense.

USER’S MANUAL
MA27-02/B
16
9. CE DECLARATION OF CONFORMITY
CE DECLARATION OF CONFORMITY
FABRICANTE PRODUCTO: DAVI & CIA S.L.
PRODUCT MANUFACTURER:
DIRECCIÓN: C/ Murcia, 35, Nave G
ADDRESS Polí ono Industrial Can Calderón
E08830 Sant Boi de Llobre at
BARCELONA - ESPAÑA
DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO:
DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT
Marca DAVI & CIA
Brand
Nombre CS4300C
Name
Tipo EQUIPO ELECTRONICO
Type Electronic equipment
Fi alidad Prevista Equipo pesapersonas.
Intended Use Wei hin equipment.
CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS:
CONFORMS WITH THE RE UISITES OF THE DIRECTIVES
EC Directive 2004/108/EC Directiva de Compatibilidad Electroma nética (Electromagnetic
Compatibility Directive)
EC Directive 2006/95/EC Directiva de Baja tensión (Low Voltaje Directive).
EC Directive 93/42/EEC Aplicable únicamente a las básculas con aprobación médica
(Applies only to scales with medical approval).
FECHA: 12 de Diciembre de 2010 DATE: 12
th
December 2 1
Nombre:
Name
J.Masana
Firmado:
Signed
Cargo:
Function
Gere te
DAVI & CIA

USER’S MANUAL
MA27-02/B
17
his manual and other support documents are available on the web
www.davicia.com
www.davicia.comwww.davicia.com
www.davicia.com
C/ Murcia, 35 Nave G Pol.industrial Can Calderón.
E 08830 Sant Boi de Llobregat. Barcelona. Spain
el. +34 93 654 32 32
Fax. +34 93 654 16 62
www.davicia.com
Table of contents