manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DELANY
  6. •
  7. Bathroom Fixture
  8. •
  9. DELANY SideArm User manual

DELANY SideArm User manual

Battery
Compartment
Wrench
4 “C” Alkaline Batteries
Collar Wrench
Collar
Gasket
SideArm
Instructions Manual
The SideArm sends out a continuous infrared beam that is reflected back by the
presence in front of the urinal or water closet.
SideArm for Water Closet
SideArm for Urinal
Collar Nut
Collar Gasket
--
+
-
++
Object Lock Sensor
User-In-View LED (Green)
-+
-
+
Object Lock Sensor
User-In-View LED (Green)
--
++
--
++
ACTIVATION
2
Remove Battery Compartment
Install Battery Compartment
INSTALLATION
1) As a precaution, it is recommended to turn
the water off at the control stop.
2) Remove Handle: With flat-jawed wrench or
collar wrench provided, unscrew the handle
nut and completely remove handle assembly.
Note: Be careful water that may be in handle
assembly.
3) Slide SideArm operating through grey collar
and gasket and into handle pad opening.
4) Tighten SideArm handle nut until it is snug.
Note: It is recommended that the handle not be
discarded, but saved it reuse is wished.
3. Using the allen-key, close and secure the battery compartment.
The last 3 turns of the locking screw will activate the SideArm's
electronics, so that it is ready to go.
Note: The range on the sensor is factory pre-set. For special
circumstances, it can be adjusted. To do so please see the
instructions below.
The SideArm has a 7 minute start-up sequence, during which the
"Object Lock Sensor" will continuously flash, while an object is in
front the sensor. It will be a green L.E.D., that is referred to as the
"User-Detection" light. After the start-up sequence is finished and
during the use, the there is 5 second delay before the User-
Detection light flashes. It will flash 3 times only. The 5 second
delay is designed to prevent false flushes.
1. With an allen-key (one supplied in box), remove the battery
compartment.
2. Load batteries into the battery compartment tray (note the proper
alignment of batteries in tray) and slide back into place.
COURTESY MANUAL FLUSH BUTTON
(Allows manual activation of
flush when needed—Toilet
model only).
VISUAL INDICATOR GUIDE
--
+
-
++
Use battery compartment wrench to remove
battery compartment tray.
Pull cover off by rotating battery side forward
and out.
Sensor Adjustor Tool comes in a built in storage
pocket.Replace after use.
TO CHANGE ACTIVATION DISTANCE FOR THE OBJECT LOCK SENSOR:
1 Remove battery compartment tray as shown at left.
2 Remove cover and sensor adjustor tool as shown at left.
3 Replace battery compartment in AutoFlush to activate unit.
4 Press sensor range reset button shown on next page (the green L.E.D.will flash continuously when it has an object in
view for the seven minute reset period).
5 Stand at desired activation distance.
6 Use sensor adjuster tool and turn Distance Adjustment Screw all the way down and then turn slowly up until green
L.E.D. begins to flash.
7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door, stepping out of sensor path and making
sure green L.E.D. is not flashing. If sensor locks onto door or wall,unit will not flush properly. Shorten activation distance.
8 Remove battery compartment,replace sensor adjustor tool and cover. Replace battery compartment tray to reactivate
AutoFlush unit.
9 After 7 minute start-up sequence, the green L.E.D. will flash only 3 times when a user is in view
(after a 5 second delay).
ADJUSTING THE SENSOR RANGE:
User-Detection L.E.D.: This green flashing light will
flash 3 times when an object comes in front during
operation. (It flashes continuously during the 7 minute start
sequence.
Object Lock Sensor
Low Battery Indicator L.E.D.:
This is a yellow light that flashes to
indicate that the 4 "C" batteries are low
and need to be replaced.
.
1
ON
2 3
1
ON
2 3 1
ON
2 3 1
ON
2 3 1
ON
2 3 1
ON
2 3
1
ON
2 3
- +
Object Lock
Range of Detection
Distance Adjustment Screw Near Far
Modes of
Operation
Switches Normal
Flushes after
each use
Water
Saver
Flushes after
every other use
Sensor Range Reset Button
Courtesy Manual
Flush Button
(Toilet Model Only)
Sanitary
Flushes before
and after
each use
Stadium
Flushes every
3 minutes with
continuous use
Audio
Tone sounds
when batteries
need to be
replaced
ON
OFF
Allows manual activation
of flush when needed.
Distance
Adjustment
Urinal Model Only
Operates
in Normal
Mode Only
Flushes after
each use
ON
1
Audio
Tone sounds
when batteries
need to be
replaced
ON
OFF
Toilet Model Only
Use Sensor
Adjuster
Tool
Battery LED (Yellow) Flashing LED = Change Batteries
Object Lock Sensor
User-In-View LED (Green) Flashes 3 Times = User acknowledged & ready
to operate per mode setting.
SWITCH
NO.3
DOES
NOT
AFFECT
NO.'S
1 & 2.
Urinal Model Only
TROUBLE SHOOTING GUIDE
PROBLEM CAUSE SOLUTION TO PROBLEM
Green L.E.D.(light) flashes 3 times
when there are no users
Green L.E.D.(light) flashes
continuously when Object Lock Sensor is
activated by a user
Orange L.E.D.(light) flashes
Not enough water to fixture or too
much water to fixture
Valve will not operate
Valve does not shut off
Valve does not flush even after Object
Lock Sensor has been adjusted
Front of Object Lock Sensor is covered or Object Lock
Sensor is set too far out,registering the opposite wall or
door as a user
activated) or Sensor Range Reset Button has been
depressed
Batteries need replacing
Diaphragm damaged or valve control stop
improperly adjusted
Object Lock Sensor range set to close to AutoFlush,batteries
are dead, or water supply
is turned off
Dirt or debris preventing diaphragm from
functioning properly
Dead batteries
Remove item covering sensor or adjust Object Lock
Sensor activation distance.(See Appendix B.Adjusting
the AutoFlush)
Green L.E.D.(light) will flash only 3 times
acknowledging a user is in view after the 7 minute
start up mode
Replace batteries
Replace diaphragm and/or adjust valve control stop
Adjust Object Lock Sensor—Replace batteries—Turn
water on.
Remove dirt or debris,consult valve manufacturer’s
directions
Replace batteries.
Delany Products
www.delanyproducts.com
(434) 296 0166 1565 Avon Street,
Charlottesville, VA 22902
(434) 296-0166 1565 Avon Street, Charlottesville, VA 22902
Unit is in 7 minute start up mode (when first

Popular Bathroom Fixture manuals by other brands

Gessi 39809 installation manual

Gessi

Gessi 39809 installation manual

Laufen LIS CU2 8.9266.4.000.000.1 manual

Laufen

Laufen LIS CU2 8.9266.4.000.000.1 manual

Robern CURATED CARTESIAN VANITY manual

Robern

Robern CURATED CARTESIAN VANITY manual

Symmons DS Creations 0600-TB-18 installation guide

Symmons

Symmons DS Creations 0600-TB-18 installation guide

Felton AXISS AXRSCC installation guide

Felton

Felton AXISS AXRSCC installation guide

Lennox DL-700 installation guide

Lennox

Lennox DL-700 installation guide

KAWAJUN SH-028-2 quick start guide

KAWAJUN

KAWAJUN SH-028-2 quick start guide

PolyJohn HandStand 2 user manual

PolyJohn

PolyJohn HandStand 2 user manual

ZUCCHETTI NUDE ZNU646 Instruction for the installation

ZUCCHETTI

ZUCCHETTI NUDE ZNU646 Instruction for the installation

Moen TL5265 Series installation guide

Moen

Moen TL5265 Series installation guide

Royal Prestige FrescaPure 2000 manual

Royal Prestige

Royal Prestige FrescaPure 2000 manual

BERNSTEIN 805S Assembly instructions

BERNSTEIN

BERNSTEIN 805S Assembly instructions

MARIMEX UNO 14 instructions

MARIMEX

MARIMEX UNO 14 instructions

Samo AMERICA B6805 Assembly instruction

Samo

Samo AMERICA B6805 Assembly instruction

Symmons 229-TP Operation & maintenance manual

Symmons

Symmons 229-TP Operation & maintenance manual

Axor 460/300 3jet 35281 Series Instructions for use/assembly instructions

Axor

Axor 460/300 3jet 35281 Series Instructions for use/assembly instructions

Hans Grohe AXOR ShowerHeaven 720 10625800 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe AXOR ShowerHeaven 720 10625800 Instructions for use/assembly instructions

Laufen INO 8.1230.0 manual

Laufen

Laufen INO 8.1230.0 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.