DeviceNet Remote I/O Communication Module RTU-DNET
DVP-PLC Application Manual 9
No. Item Unit Explanation
5 Length of input data
of special module Word The length of input data of the special module connected to
RTU-DNET
6 Length of output
data of special
module Word The length of output data of the special module connected to
RTU-DNET
7 Length of input I/O
data Byte
The sum of the length of the status word of RTU-DNET and the
input data of the special module connected to it. One input
channel of the special module occupies 2 bytes. 8 points of the
digital input are counted as 1 byte.
8 Length of output I/O
data Byte
The sum of the length of the control word of RTU-DNET and
theoutput data of the special module connected to it. One output
channel of the special module occupies 2 bytes. 8 points of the
digital output are counted as 1 byte.
9 Number of special
modules Unit The number of special modules connected to RTU-DNET.
Range: 0 ~ 8
10 Diagnostic interval
time Sec The interval when RTU-DNET executes diagnosis.
Range: 1 ~ 65, Default: 5 secs
11 Special module
offline treatment N/A How RTU-DNET will react when the special module connected
to it is offline. You can choose “Ignored”, “Alarm” or “Stop
DeviceNet IO”. Default: Alarm
12 Special module erro
treatment N/A How RTU-DNET will react when it detacts errors. You can
choose “Ignored”, “Alarm” or “Stop DeviceNet IO”. Default:
Alarm
13 Reset RTU-DNET N/A Reset the configuration of RTU-DNET to default settings.
14 Add control word
and status word to
I/O data N/A
For you to decide whether to add control word and status word
to I/O data. When you choose not to do it, the I/O data in
RTU-DNET and DeviceNet master will not include control word
and status word. If you choose to add them in, the I/O data in
RTU-DNET and DeviceNet master will include control word and
status word.
15 Work mode N/A
For you to set up the work mode of the special module
connected to RTU-DNET. When set to “auto mode”, RTU-DNET
will configure default CR of the special module as DeviceNet I/O
mapping data. When set to “custom mode”, you can configure
any CR in the special module as DeviceNet I/O mapping data.
16 Number of input
data connected --- The number of input data of the special module connected to
RTU-DNET
17 Number of output
data connected --- The number of output data of the special module connected to
RTU-DNET
18 Length of input data Word The sum of the length of input data of the special modules
connected to RTU-DNET
19 Length of output
data Word The sum of the length of output data of the special modules
connected to RTU-DNET
20 I/O mapping N/A The I/O mapping relation between RTU-DNET and the special
module connected to it
4.2 Format of Requet Message and Response Message
1. RTU-DNET supports using DeviceNet explicit messages to poll special modules.
Format of request messages
Byte position Data written into special module Data read from special module
0 Frag[0]+XID+MAC ID Frag[0]+XID+MAC ID