Digital Electronics Corporation Pro-face Flex Network GLC100-FN11 User manual

Flex Network
User Manual
Digital Electronics Corporation

1
Flex Network User Manual
Preface
Thank you for purchasing Pro-face's Flex Network units, hereafter referred to as
the "Unit".
The Unit is designed to be used with Pro-face's Graphic Logic Controller or Pro-
face's LogiTouch Series units (hereafter referred to collectively as the "GLC") for
distributed I/O connection.
This manual explains the overall features and specifications of the Unit, as well as
its installation procedures.
Please be sure to read this manual thoroughly to understand the correct and safe
usage of this product and its features.
<Note>
1) It is forbidden to copy the contents of this manual, in whole or in part, except
for the user's personal use, without the express permission of Digital Electron-
ics Corporation of Japan.
2) The information provided in this manual is subject to change without notice.
3) This manual has been written with care and attention to detail; however, should
you find any errors or omissions, please contact Digital Electronics Corporation
and inform us of your findings.
4) Please be aware that Digital shall not be held liable by the user for any dam-
ages, losses, or third party claims arising from the uses of this product.
All Company/Manufacturer names used in this manual are the registered trade-
marks of those companies.
© 2001, Digital Electronics Corporation
Flex Network®is a registered trademark of Digital Electronics Corporation in
Japan and other countries.

2Flex Network User Manual
Preface
Table of Contents
Preface........................................................................................................................ 1
Table of Contents...................................................................................................... 2
Essential Safety Precautions................................................................................... 4
General Precautions................................................................................................. 6
Documentation Conventions................................................................................... 7
Flex Network Unit Models...................................................................................... 7
Compatible GLC Units............................................................................................ 8
UL/c-UL(CSA) Approval ........................................................................................ 9
CE Marking............................................................................................................. 11
CHAPTER 1 INTRODUCTION
1.1 System Design.............................................................................................1-1
1.2 Flex Network Unit Types ..........................................................................1-3
CHAPTER 2 SPECIFICATIONS
2.1 General Specifications...............................................................................2-1
2.1.1 Electrical ........................................................................................2-1
2.1.2 Environmental................................................................................ 2-2
2.1.3 Structural ........................................................................................2-3
2.2 Performance Specifications......................................................................2-4
2.2.1 Data Transfer Settings ...................................................................2-4
2.2.2 Flex Network I/O Unit Input/Ouput .............................................2-4
2.3 Input/Output Circuit Drawings.............................................................2-10
2.4 Part Names and Features........................................................................2-17
2.4.1 Flex Network I/F Unit .................................................................2-17
2.4.2 Flex Network I/O Unit ................................................................2-18
2.5 Dimensions ................................................................................................2-21
2.5.1 Flex Network I/F Unit .................................................................2-21
2.5.2 Flex Network I/O Unit ................................................................2-23
CHAPTER 3 INSTALLATION AND WIRING
3.1 Installation ..................................................................................................3-1
3.1.1 Flex Network I/F Unit Installation ...............................................3-1
3.1.2 I/O Unit Installation/Removal ......................................................3-2
3.1.3 Attaching a 32-Point I/O Unit.......................................................3-4

3
Flex Network User Manual
Preface
3.2 Wiring ..........................................................................................................3-5
3.2.1 Connecting the Flex Network Data Transfer Cable ....................3-5
3.2.2 Connecting the Power Cord .......................................................... 3-8
3.2.3 Connecting the I/O Cable..............................................................3-9
3.2.4 General Cautions ......................................................................... 3-11
CHAPTER 4 PROBLEMS AND SOLUTIONS
4.1 Problem Solving ...........................................................................................4-1
4.1.1 Prior to Troubleshooting ...............................................................4-1
4.1.2 Error Code Display........................................................................4-2
4.1.3 Troubleshooting ............................................................................. 4-3
INDEX

4Flex Network User Manual
Preface
• An emergency stop circuit and an interlock circuit should
be constructed outside of this Unit. Constructing these
circuits inside a system that uses this Unit may cause a
runaway situation, system failure, or an accident due to
unit failure.
• Systems using this Unit should be designed so that out-
put signals which could cause a serious accident are
monitored from outside the Unit.
• This Unit is designed to be a general-purpose device for
general industries, and is neither designed nor produced
to be used with equipment or systems in potentially life-
threatening conditions. If you are considering using this
Unit for special uses, including nuclear power control
devices, electric power devices, aerospace equipment,
medical life support equipment, or transportation ve-
hicles, please contact your local Pro-face distributor.
This guide contains a variety of safety markings for safe and correct operation of
this Unit. Please read this installation guide and any related manuals carefully to
fully understand how to correctly use this Unit's functions.
Safety Symbols
Please pay attention to these symbols and follow all instructions given.
The safety symbols and their meanings are as follows:
Indicates situations where severe
bodily injury, death or major ma-
chine damage will definitely occur.
Indicates situations where severe
bodily injury, death or major ma-
chine damage can possibly occur.
Indicates situations where slight
bodily injury or machine damage can
occur.
DANGER
WARNING
CAUTION
DANGERS
Essential Safety Precautions

5
Flex Network User Manual
Preface
• Communication cables or I/O signal lines must be wired
separately from the main circuit (high-voltage, large-cur-
rent) line, high-frequency lines such as inverter and
power lines. Otherwise, a malfunction may occur due to
noise.
• This Unit must be installed according to directions given
in its Installation Guide and User manual. Improper instal-
lation may cause the Unit to malfunction or fail.
• This Unit must be wired according to directions in the
Installation Guide and User Manual. Improper wiring may
cause a malfunction, failure or electric shock.
• Do not allow foreign substances, including chips, wire
pieces, water, or liquids to enter inside this Unit's case.
Otherwise, a malfunction, failure, electric shock, or fire
may occur.
• When disposing of this Unit, it should be processed ac-
cording to your country's industrial waste disposal laws.
CAUTIONS
• Prior to installing, removing, wiring, and conducting main-
tenance or inspections, be sure to disconnect power to
this Unit to prevent an electric shock or fire.
• Do not disassemble or remodel this Unit, since it may lead
to an electric shock or fire.
• Do not use this Unit in an environment that contains flam-
mable gases since an explosion may occur.
• Do not use this Unit in an environment that is not speci-
fied in either the Installation Guide or User Manual. Other-
wise, an electric shock, fire, malfunction or other failure
may occur.
• Due to the possibility of an electric shock or malfunction,
do not touch this Unit's power terminals it is operating.
WARNINGS

6Flex Network User Manual
Preface
To Prevent Unit Damage
• Avoid storing or operating this Unit in either direct sunlight or excessively
dusty or dirty environments.
• Because this Unit is a precision instrument, do not store or use it in locations
where excessive shocks or vibration may occur.
• Avoid covering this Unit's ventilation holes, or operating it in an environment
that may cause it to overheat.
• Avoid operating this Unit in locations where sudden temperature changes can
cause condensation to form inside the Unit.
• Do not use paint thinner or organic solvents to clean this Unit.
General Precautions

7
Flex Network User Manual
Preface
Documentation Conventions
Flex Network Unit Models
Flex Network Units allow the GLC to communicate via a Flex Network system.
The available Flex Network Unit model numbers are shown below.
The list below describes the documentation conventions used in this manual.
Symbol Meaning
Indicatesimportantinformation orproceduresthatmustbefollowedfor
correctandrisk-freesoftware/device operation.
*1 Indicatesuseful orimportantsupplementalinformation.
1) , 2) Indicatesstepsin aprocedure.Besuretoperform thesestepsin the
ordergiven.
Referstousefulorimportantsupplemental information.
Providesuseful orimportantsupplementalinformation.
Pro-Control
Editor IndicatesthePro-ControlEditorladderlogic developmentsoftware.
1:N Indicatesamulti-linktypeconnection isused.
GLC Generic nameforthe"GLCSeries"ofGraphic Logic Controllersmade
byDigitalElectronic Corporation.Inthismanual,italsoindicates
"LogiTouch"Seriesunits".
SystemName Unit Name Model No. Rating Memo
GLC100-FN11 StandardUnit -
GLC100-FN41 UL/c-UL(CSA)Approved,
CEMarkedUnit -
FN-X16TS11 StandardUnit
FN-X16TS41 UL/c-UL(CSA)Approved,
CEMarkedUnit
FN-XY08TS11 StandardUnit
FN-XY08TS41 UL/c-UL(CSA)Approved,
CEMarkedUnit
FN-Y08RL11 StandardUnit
FN-Y08RL41
FN-Y16SK41
FN-Y16SC41
FN-Y32TS41
FN-XY16SK41 32Points
FN-XY16SC41
8/16 Points
Flex Network
Unit
FlexNetwork
I/F Unit*1
FlexNetwork
I/O Unit
UL/c-UL(CSA)Approved,
CEMarkedUnit
UL/c-UL(CSA)Approved,
CEMarkedUnit
*1 The Flex Network I/F Unit (GLC100-FN11/GLC100-FN41) is compatible with all GLC100
Series and GLC300 Series units. It is not required for GLC2000 Series, or LogiTouch Series
units.

8Flex Network User Manual
Preface
The following GLC units can be used with the Flex Network I/O and I/F units.
Compatible GLC Units
*1 The 32 Point Flex Network I/O Unit (FN-X32TS41/FN-XY16SK41/FN-XY16SC41) is
compatible with all GLC2000 Series and LogiTouch Series units.
*2 The LogiTouch Type A* unit is not compatible with the Flex Network.
General
Name Unit Name Model No. Memo
GLC100L GLC100-LG41-24V
GLC100S GLC100-SC41-24V
GLC300S GLC300-TC41-24V
Requires
FlexNetwork
I/F Unitand
BusCon-
version Unit
GLC2300L GLC2300-LG41-24V
GLC2300T GLC2300-TC41-24V
GLC2400
Series GLC2400T GLC2400-TC41-24V
GLC2600
Series GLC2600T GLC2600-TC41-24V
LogiTouch Type-B GLC150-BG41-FLEX-24V
LogiTouch Type-C GLC150-BG41-RSFL-24V
Requires
FlexNetwork
I/F Unit
GLC
Series Name
GLC300Series
GLC2000
Series*1
GLC100Series
GLC2300
Series
LogiTouchSeries*1 *2

9
Flex Network User Manual
Preface
UL/c-UL(CSA) Approval
The GLC100-FN41 is a UL/c-UL(CSA) listed product. (UL file No.E182139)
This unit conforms to the following standards:
UL508
Industrial Control Equipment
UL1604
For use with Electrical Equipment in Class I and II, Division 2 and Class III
Hazardous (Classified) Locations in industrial control applications.
CAN/CSA-C22.2, No. 1010-1
Safety requirements for electrical equipment for measurement and labora-
tory use.
GLC100-FN41 (UL Registration Model: 2880063-01)
<Cautions>
• The GLC must be used as a built-in component of an end-use product.
• This unit is designed to be attached to a GLC100 Series or GLC300 Series unit.
• If the GLC is installed so as to cool itself naturally, be sure to install it in a
vertical panel. Also, be sure that the GLC is mounted at least 100 mm away
from any adjacent structures or equipment. If these requirements are not met,
the heat generated by the GLC's internal components may cause the unit to fail
to meet UL/c-UL standard requirements.
UL1604 Conditions of Acceptability and Handling Cautions:
1. Power, input and output (I/O) wiring must be in accordance with Class I, Division 2
wiring methods - Article 501- 4(b) of the National Electrical Code, NFPA 70
within the United States, and in accordance with Section 18-152 of the Canadian
Electrical Code for units installed within Canada.
2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Loca-
tions.
3. WARNING: Explosion hazard - substitution of components may impair suitability
for Class I, Division 2.
4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF
before replacing or wiring modules.
5. WARNING: Explosion hazard - do not disconnect equipment unless power has
been switched OFF, or the area is known to be non-hazardous.
Flex Network I/F Unit

10 Flex Network User Manual
Preface
Flex Network I/O Units
The following Flex Network units are UL/c-UL (CSA) approved.
• FN-X16TS41 (UL File No. E 195835)
• FN-XY08TS41 (UL File No. E 195835)
• FN-Y08RL41 (UL File No. E 195835)
• FN-Y16SK41 (UL File No. E 195835)
• FN-Y16SC41 (UL File No. E 195835)
• FN-X32TS41 (UL File No. E 220851)
• FN-XY16SK41 (UL File No. E 220851)
• FN-XYL16SC41 (UL File No. E 220851)
These Units conform to the following standards:
UL508
Industrial Control Equipment
CAN/CSA-C22.2, No. 1010-1
Safety requirements for electrical equipment for measurement and labora-
tory use.
FN-X16TS41 (UL Registration Model: 2880063-02)
FN-XY08TS41 (UL Registration Model: 2880063-03)
FN-Y08RL41 (UL Registration Model: 2880063-04)
FN-Y16SK41 (UL Registration Model: 2880063-05)
FN-Y16SC41 (UL Registration Model: 2880063-06)
FN-X32TS41 (UL Registration Model: 3080039-01)
FN-XY16SK41 (UL Registration Model: 3080039-02)
FN-XY16SC41 (UL Registration Model: 3080039-03)
<Cautions>
• This Unit must be used as a built-in component of an end-use product.
• If this Unit is installed so as to cool itself naturally, be sure to install it on a
vertical DIN rail or to a vertical panel via attachment holes. Also, be sure that
this Unit is mounted at least 100 mm away from any adjacent structures or
equipment. If these requirements are not met, the heat generated by this Unit's
internal components may cause the Unit to fail to meet UL/c-UL standard
requirements.
• Any power supply device connected to the Unit should be a UL/c-UL(CSA)
approved Class 2 power supply or Class 2 transformer. *1
Single unit power supplies, when connected to this Unit, multiple I/O units or
when driving a load, should be designed so that the total power consumption of
the I/O unit(s) and the total load current meets the standards for a Class 2
power supply, or a Class 2 power transformer.
Also, be aware that the number of load producing points, and the load current
value will determine the number of output points that can be simultaneously
turned ON.
*1 Class 2 power supplies and Class 2 transformers should not exceed an output of 30V, and
at 8A or less, should not exceed 100V.

11
Flex Network User Manual
Preface
CE Marking
The GLC100-FN41 is a CE marked product that conforms to EMC directives
EN55011 Class A and EN61000-6-2 (EN50082-2).
<Cautions>
Even though the GLC meets the abovementioned EMC standards, if it is installed
into another piece of machinery, that machinery's installation, wiring or position-
ing method(s) used may cause the GLC to fail to meet the designated EMC stan-
dard. Therefore, the combination of the GLC and this machinery may need to be
re-tested, as a final, complete unit.
* For detailed CE marking information, please contact your local Pro-face distributor.
Flex Network I/O Units
Flex Network I/F Unit
The following Flex Network Units are CE marked products that conform to EMC
directives EN55011 Class A and EN61000-6-2.
[Compatible Units]
FN-X16TS41, FN-XY08TS41, FN-Y08RL41, FN-Y16SK41,
FN-Y16SC41, FN-X32TS41, FN-XY16SK41, FN-XY16SC41
* For detailed CE marking information, please contact your local Pro-face distributor.

12 Flex Network User Manual
Preface
Memo

1-1
Flex Network User Manual
Flex Network I/F Unit *1 Flex Network I/O Unit
GLC
Maximum cable length: 200m (6Mbps) 100m (12Mbps)
Maximum No. of Units: 31
With One (1) Channel
1.1 System Design
Chapter
1 Introduction
1. System Design
2. Flex Network Unit Types
This chapter explains the standard system design for the Flex Network unit, and
the types of units available.
The following information explains how to connect the GLC to a Flex Network
I/F and I/O Unit.
When connecting the I/O unit, 2 channels are available - CH1 and CH2. Each
channel outputs the same data and either can be used for data transmission.
The maximum number of connectable units, when using a single channel, is 31,
and when using a second channel, the number increases by 32 to a total of 63.
• The Flex Network uses high speed data transfer technology, and if a
is cable used for data transfer that is not the same as that specified
in this document, network data transfer performance cannot be guar-
anteed. Thus, be sure to use only the cable(s) recommended here.
3.2.1 Connecting the Flex Network Data Transfer Cable
• When connecting the Flex Network I/F unit to a GLC 300 Series op-
erator interface, the optional Bus Conversion unit is required. (Model
No. GLC300-BCB41).
• When turning the entire system's power ON, turn on the I/O unit's
power supply before turning on the GLC's power.
*1 GLC2000 Series/LogiTouch Series do not require the Flex Network I/F Unit.

1-2 Flex Network User Manual
Chapter 1 - Installation
16 Input Points
GLC
8 points - relay output
Sensor
Operation
Switch
DC24V DC24V
8 points Input/
8 points Output
32 Input points
Valve Actuator
Lamp
DC24V DC24V
to next station *1
Flex Network I/O Unit
Flex Network I/F Unit
GLC
6Mbps is the recommended speed.
With Two (2) Channels
Maximum cable length: 400m (6Mbps), 200m (12Mbps)
Maximum No. of units: 63 (31 + 32)
Standard System Design
to next station *1
*1 Be sure the Terminal Switch (TERM) of the network's last unit (at each end) is turned ON.
2.4.2 Flex Network I/O Unit
Sensor
Operation
Switch
Sensor
Operation
Switch
When using two channels, up to 32 nodes can be connected to either channel.
CH1
CH2

1-3
Flex Network User Manual
Chapter 1 - Installation
1.2 Flex Network Unit Types
The following tables explain the different types of Flex Network units. These are
optional GLC units and are sold separately.
I/O Units
Expansion Units
I/F Unit
Item Model No. Description
Flex Network
I/F Unit GLC100-FN11
GLC100-FN41
AttachedtorearofGLC100orGLC300seriesunitsto
allowdatatransferoveraFlexNetwork.Notrequiredfor
GLC2000Series/LogiTouchSeriesunits.
GLC300SeriesunitsrequiretheseparatelysoldBus
ConversionUnit.
Item Model No. Description
Flex Network
16-point Input
Sink-Source type
I/O Unit
FN-X16TS11
FN-X16TS41
16-pointsink-source type shared I/O Unit.
Sink-source can be selected by wiring between the inputcircuit
andcommon(COM terminal) cabling.
Flex Network
8-pt Input Sink-
Source / 8-pt
Transistor Output
Sink type I/O Unit
FN-XY08TS11
FN-XY08TS41
I/O Unitwith combination of8-ptsink-source inputs and 8-pt
transistor sink outputs. Can be connected to DC24V, 200mA
electromagnetic bulb, or pilotlamp for output.
Flex Network 8-pt
Relay Output /
1 Common type
I/O Unit
FN-Y08RL11
FN-Y08RL41 8-pointrelay output/ 1 common type I/O unit. Can be
connectedtoAC240V(1A load).
Flex Network
16-point Output
Sink type I/O Unit FN-Y16SK41 16-pointsink outputI/O unit
Flex Network 16-pt
Output Source
type I/O Unit FN-Y16SC41 16-pointsource outputI/O unit.
Flex Network
32-point Input
Sink-Source type
I/O Unit
FN-X32TS41 32-pointsink-source type shared I/O Unit.
Sink-source can be selected by wiring between the inputcircuit
andcommon(COM terminal) cabling.
I/O Unitwithcombinationof16-ptsink-source inputs and16-pt
transistor source outputs. Can be connected to DC24V, 200mA
electromagnetic bulb, or pilotlamp for output.
I/O Unitwithcombinationof16-ptsink-source inputs and16-pt
transistor sink outputs. Can be connected to DC24V, 200mA
electromagnetic bulb, or pilotlamp for output.
Flex Network 16-pt
Input Sink-
Source /16-pt
Transistor Output
Sink type I/O Unit
FN-XY16SK41
Flex Network
16-pt Input Sink-
Source/16-pt
Transistor Output
Source type I/O
Unit
FN-XY16SC41

1-4
Flex Network User Manual
Analog Unit
Item Model No. Description
Flex Network 4-
Channel Analog/
Digital Conversion
Input Unit
FN-AD04AH11 Stores analog signal in this unitafterconverting itto
12-bitdigital signal.
Flex Network 4-
Channel Analog/
Digital Conversion
Output Unit
FN-DA04AH11 Converts12-bitdigital signal toanalogsignaland
sendsoutput.
Optional Expansion Unit
Optional Items
High-Speed Counter Unit
Maintenance Items
Single Axis Positioning Unit
Item Model No. Description
Flex Network
Single-Axis
Positioning Unit FN-PC10SK41 Controlsa servomotorandsteppingmotor.
Handles up to 2MHz.
Item Model No. Description
Single-Axis
Teaching Loader
Cable
FN-LD10CBL
(5m) ConnectstheFlexNetworksingle-axispositioning
unitandthesingle-axisteachingloader.
Item Model No. Description
Single-Axis
Teaching Loader FN-PC10LD41
Program-inputunitfortheFlexNetworksingle-axis
positioning unit.Used forparameterentry,aswell as
positioning checkand movement.(includes one piece
ofFN-LD10CBL.)
Single-Axis Motor
Driver Connection
Cable
FN-PC10CB01
(1m) Connects the FlexNetwork single-axis positioning
unitand the servo and steppingdrivers.
FN-CABLE2010-
31-MS (10m)
FN-CABLE2050-
31-MS (50m)
FN-CABLE2200-
31-MS (200m)
Flex Network
Communication
Cable Connectsdistributed FlexNetwork units.
Item Model No. Description
Bus Conversion
Unit GLC300-BCB41
Thisunitisattachedtotherearofthe GLC300Series.
Itmust be attached before the Flex Network I/F
(GLC100-FN11/GLC100-FN41)unitisattachedto
theGLC300Seriesunit.
Item Model No. Description
Flex Network
High-Speed
Counter Unit FN-HC10SK41
Maximum speed is200Kpps.Canbe usedin
combinationwithpositioningunitsandworkrate
counterstoperform cuttingapplications,dueto the
simultaneousoutputandprogrammablecam switch
features.

2-1
Flex Network User Manual
2.1 General Specifications
Chapter
2 Specifications
1. General Specifications
2. Functional Specifications
3. I/O Circuit Connection Drawings
4. Part Names and Features
5. Dimensions
2.1.1 Electrical
Flex Network I/F Unit
Flex Network I/O Unit (Control Section)
RatedVoltage
PowerConsumption
VoltageEndurance
Insulation Resistance DC500Vat10MΩorhigher
(betweenexternalchargingand FG terminals)
1.25W orless
DC5V+/-5%(suppliedfrom GLC)
AC1500V10mA for1min.
(betweenexternalchargingand FG terminals)
The Flex Network I/F Unit (GLC100-FN11/GLC100-FN41) is compatible with all
GLC100 Series and GLC300 Series units. It is not required for GLC2000 Series/
LogiTouchSeriesUnits.
GLC2000 Series User Manual/LogiTouch Series User Manual
FN-X16TS11/FN-X16TS41
FN-XY08TS11/FN-XY08TS41
FN-Y16SK41/FN-Y16SC41
FN-Y08RL11
FN-Y08RL41
FN-X32TS41
FN-XY16SK41
FN-XY16SC41
RatedVoltage
RatedVoltageRange
Allowable Voltage
Interrupution
PowerConsumption 1.5Worless 1Worless 2.5Worless
VoltageEndurace
AC500V10mAfor1
min.(between
power/Inputand
Output,and FG
terminals)
Insulation Resistance
In-rushCurrent 30Aorless
DC20.4Vto DC28.8V
10msorless(PowerSupply:DC24V)
DC24V
AC1500V10mA for1min.
(betweenpower/Inputand Output,
andFG terminals)
DC500Vat10MΩorhigher
(betweenpower/InputandOutput,andFGterminals)

Chapter 2 - Specifications
2-2 Flex Network User Manual
Flex Network I/F Unit
Flex Network I/O Unit
2.1.2 Environmental
OperatingTemperature 0oCto50oC(cannotbehigherthanGLCunit)
StorageTemperature -20oC to+60oC
OperatingHumidity 20%RHto85%RH(non-condensing)
StorageHumidity 20%RHto85%RH(non-condensing)
AirPurity(Dust) 0.1mg/m3orless(non-conductivelevels)
Corrosive Gasses Freeofcorrosivegasses
VibrationEndurance 10Hzto25Hz 19.6m/s2(inX,Y,Zdirectionsfor30min.each)
Noise Immunity
(vianoisesimulator)
Noise Duration:1000Vp-p
PulseDuration:1µs
Rise Time: 1ns
Electrostatic Discharge
Immunity GLC100-FN11:4kV(contactdischarge)
GLC100-FN41: 6kV(IEC61000-4-2,RH-1/ESD-3)
FN-X16TS11/FN-X16TS41
FN-XY08TS11/FN-XY08TS41
FN-Y16SK41
FN-Y16SC41
FN-Y08RL11/FN-Y08RL41
FN-X32TS41
FN-XY16SK41
FN-XY16SC41
OperatingTemperature
StorageTemperature
OperatingHumidity
StorageHumidity
AirPurity(Dust)
Corrosive Gasses
VibrationEndurance 5Hz to 55Hz
60m/s2
(in X,Y,Z directions for 2 hours each)
IEC61131-2 (JIS B 3501) compliant
Whenvibration IS NOT continuous:
10Hz to 57Hz 0.075mm,
57Hz to 150Hz 9.8m/s2
Whenvibration IS continuous:
10Hz to 57Hz 0.035mm,
57Hz to 150Hz 4.9m/s2
X,Y,Zdirections for 10times (80 min.)
ShockEndurance 300m/s2(for 10ms inX,Y,Zdirections -
3times each)
IEC61131-2 (JIS B 3501) compliant
147m/s2(for 11ms inX, Y, Zdirections
-2times each)
Noise Immunity
(vianoisesimulator)
Electrostatic Discharge
Immunity
Noise Voltage: 1000Vp-p, Pulse Duration: 1µs, Rise Time: 1ns
6kV(IEC61000-4-2, RH-1/ESD-3)
0oC to 55oC
-25oC to +70oC
5%RH to 95%RH (non-condensing) (wetbulb temperature: less than 39°C)
0.1mg/m3or less (non-conductive levels)
5%RH to 95%RH (non-condensing) (wetbulb temperature: less than 39°C)
Free ofcorrosive gasses

Chapter 2 - Specifications
2-3
Flex Network User Manual
2.1.3 Structural
Flex Network I/F Unit
Flex Network I/O Unit
CoolingMethod Naturalaircirculation
Weight 350gorless
ExternalDimensions W111mm [4.37in.]xH120mm [4.72in.]xD31.5mm [1.24in.]
(Main unitonly,notincludingconnector)
FN-X16TS11/FN-X16TS41
FN-XY08TS11/FN-XY08TS41
FN-Y16SK41
FN-Y16SC41
FN-Y08RL11/FN-Y08RL41
FN-X32TS41
FN-XY16SK41
FN-XY16SC41
AttachmentMethod
CoolingMethod
Weight 150g orless 350gorless
ExternalDimensions W108mm [4.25in.]xH45mm
[1.77in.] xD 49mm [1.93in.] W110mm [4.33in.]xH95mm
[3.74in.] xD 57mm [2.24in.]
Rating
via 35mm DINrail orbyattachmentscrews
Natural aircirculation
IP20
This manual suits for next models
12
Table of contents
Popular I/O System manuals by other brands

Measurement Computing
Measurement Computing USB-1208HS user guide

M-system
M-system R1M-P4 instruction manual

M-system
M-system R7F4HML3-D-DAC32B instruction manual

turck
turck TBIP-L...-FDIO1-2IOL... Instructions for use

WAGO
WAGO Automation WAGO-I/O-SYSTEM 750 manual

National Instruments
National Instruments 9232 Operating instructions and specifications

NI
NI 9238 Getting started guide

Pilz
Pilz PSSuniversal PSSu E F ABS SSI operating manual

Seneca
Seneca Z-4AI user manual

National Instruments
National Instruments sbRIO-9219 Operating instructions and specifications

Andover Controls
Andover Controls Continuum UI-8-10 Technical manual

M-system
M-system R7F4DC-DAC16C-H instruction manual