Installaon Guide SLC 8000 I/O Module Module Extractor
1. Shut down the SLC 8000 either via the Web Manager or the Command Line Interface and unplug all power cords.
A) Web Manager
B) Command Line Interface
admin shutdown
DISCONNECT ALL POWER
CORDS ON THE SLC 8000
BEFORE INSTALLING THIS
MODULE TO AVOID
ELECTRICAL SHOCK. THE SLC
8000 MAY HAVE MORE
THAN ONE POWER SOURCE.
DO NOT HOT SWAP.
WHAT’S IN THE BOX
Note: When you use this command to shut down the SLC unit, the LCD front panel
displays "Shung down the SLC," followed by a pause, and then "Shutdown
complete." When "Shutdown complete" displays, it is safe to power o the SLC
console manager. This command is not available on the web page.
2. Take out the ller panel if you are adding, or take out the exisng module if you are replacing.
B) Using the Extractor (if the release lever is not accessible)
i) Insert: Insert it until the keys are behind the metal panel.
ii) Pinch and pull: Gently pinch the extractor from both sides
and pull until the I/O module is completely removed.
A) Using the Release Lever
i) Press and pull: Gently press the release lever
from underneath and pull the I/O module
until it is completely removed.
Release Lever
Keys Metal Plate
Blade
Extractor
RJ45 Loopback Cable
INSTALL
GUIDE
Only for RJ45 I/O Module
BEFORE YOU INSTALL
THE I/O MODULE IS
ELECTROSTATIC-
SENSITIVE. ONLY
HANDLE AT A STATIC-
FREE WORKPLACE.
THE USB I/O MODULE
(FRUSB1601) REQUIRES
SLC 8000 FIRMWARE 7.2
OR ABOVE. DOWNLOAD
THE LATEST VERSION AT:
www.lantronix.com/
support/downloads
F/W
© 2015 Lantronix, Inc. Lantronix is a registered trademark, and SLC is a trademark of Lantronix, Inc. All other trademarks are the
property of their respecve owners. Specicaons subject to change without noce. 900-722-R Rev C
Contact Technical Support
For technical support queries, visit hp://www.lantronix.com/support or call (800) 422-7044 Monday – Friday from 6:00 a.m. – 5:00 p.m., Pacic Time, excluding holidays.
Latest Firmware For the latest rmware downloads, visit hp://www.lantronix.com/support/downloads
IP Address Assignment Tutorial To view a tutorial on how to assign an IP address, visit hp://www.lantronix.com/support/tutorials
3. Insert the new I/O module into the unpopulated bay with the module’s blades aligned to the SLC 8000 unit’s rails.
4. Plug the power cord(s) back in and power on the SLC 8000.
5. The SLC 8000 automacally detects the new module. Aer boot up has completed, you can conrm that the new
module has been detected via the Web Manager’s About Page ( ? icon) or the Command Line Interface.
A) Web Manager: While the model number will change to reect the nal port count (e.g. SLC8024, SLC8032,
SLC8040, SLC8048), the dashboard will also show the newly added acve ports in green.
The acve modules can be checked in order from Bay 1 to 3 under I/O Module Type(s):
(e.g. RJ45-08, RJ45-16, USB-16)
B) Command Line Interface
admin version
show sysstatus
Correct Incorrect
Bay 1 Bay 2 Bay 3 Bay 1 Bay 2 Bay 3
!Thank you for choosing Lantronix. Please register this product in order to receive nocaons for
rmware and documentaon updates at www.lantronix.com/product-registraon.
Model Number Dashboard
Note: Using this command allows you to check the new model number reecng the
nal port count, and all of installed I/O modules under I/O Module Type(s).
Note: Using this command also allows you to check how many device ports are
detected and what the status of each one is.
Each Bay must be populated in order from 1 to 3.
Note
Empty Empty
Empty Empty
Empty
Empty
Empty
Empty Empty

Other manuals for SLC 8000

3

Popular I/O System manuals by other brands

Motorola Piccolo-XR owner's manual

Motorola

Motorola Piccolo-XR owner's manual

Mitutoyo IT-007R user manual

Mitutoyo

Mitutoyo IT-007R user manual

ICP DAS USA A-823PGH Series quick start guide

ICP DAS USA

ICP DAS USA A-823PGH Series quick start guide

NI myRIO-1900 USER GUIDE AND SPECIFICATIONS

NI

NI myRIO-1900 USER GUIDE AND SPECIFICATIONS

MG R6D-SV2 instruction manual

MG

MG R6D-SV2 instruction manual

Allen-Bradley SLC 500 user manual

Allen-Bradley

Allen-Bradley SLC 500 user manual

Solid State Logic Multichannel Digital Audio Interface... reference guide

Solid State Logic

Solid State Logic Multichannel Digital Audio Interface... reference guide

Peak MU-Thermocouple1 CAN user manual

Peak

Peak MU-Thermocouple1 CAN user manual

Fortec Star COMe-mBT10 manual

Fortec Star

Fortec Star COMe-mBT10 manual

Balluff BNI PNT-507-005-Z040 installation guide

Balluff

Balluff BNI PNT-507-005-Z040 installation guide

ICP DAS USA M-7011D quick start guide

ICP DAS USA

ICP DAS USA M-7011D quick start guide

M-system R80UST4 instruction manual

M-system

M-system R80UST4 instruction manual

Mitsubishi A8GT-50KBF user manual

Mitsubishi

Mitsubishi A8GT-50KBF user manual

Extron electronics 70-151-01 user guide

Extron electronics

Extron electronics 70-151-01 user guide

Siemens SIMATIC ET 200L manual

Siemens

Siemens SIMATIC ET 200L manual

Baumuller SI4000 operating instructions

Baumuller

Baumuller SI4000 operating instructions

National Instruments SC-206 Series user manual

National Instruments

National Instruments SC-206 Series user manual

Siemens Simatic S7-1500 manual

Siemens

Siemens Simatic S7-1500 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.