m-Dimension AutoGet Wifi User manual

Please read this manual thoroughly before use.
Properly keep this manual with the equipment
for future reference.
AutoGet Wifi
Intelligent Fiber Endface Microscope

Introduction
Dear customer:
Thank you for choosing AutoGet Wifi product. This product has high quality and excellent perfor-
mance. To make full use of this product, please read this manual carefully before using. Whenever
you have any questions, please contact us and we are happy to support.
1.Any change of this manual will not be prior informed. Please kindly understand.
2.Every effort was made to ensure the accuracy of the manual. However , If there is no clear,
erroneous or ambiguous content founded in the manual, please contact us.
1.Keep the optics clean.
2.Keep the monitor clean. Prevent TFT LCD screen from the sharp cut, or being crushed by the
weight.
3.Put the device in suit box if no use for long time.
4.Please check the battery level of the device before use, If only one battery indicator is on and
flashing, please recharge the device before using.
The following symbols are used for the important information in this manual.
The notice and restrictions in the process.
Symbols
Attention
About the product
Prompt
1
AutoGetWifi Intelligent Fiber Endface Microscope

Product Warranty
We warrant that for a period of one (1) year from the shipping date, the product purchased by
customer shall be free of defects in material and workmanship under normal authorized use.
In the event that we receives notice during the warranty period that any part does not conform to
its warranty, our sole and exclusive liability shall be, at its sole option, to either repair or replace
the non-conforming part in accordance with this limited warranty.
No warranty will apply if
1) Device damage caused by wrong operation;
2) Unconventional repair or modification;
3) The causes of failure outside of the instrument;
4) Used in high temperature and humidity, corrosive gas, harsh conditions such as vibration;
5) Fires, earthquakes and other natural disasters as well as the pollution caused by radioactive
substances and harmful substances, and when the other force majeure such as war, riot, crime.
6) Consumables and consumable parts.
2
AutoGetWifi Intelligent Fiber Endface Microscope
Warranty Term
Warranty Content
Warranty Exception

About the Manual
This chapter describes the name and function of each part.
This chapter describes performance characteristics and the basic operation of the
equipment.
3
AutoGetWifi Intelligent Fiber Endface Microscope
Profile
Hardware basic operation
This chapter introduces software installation, features, interface and basic operation
instructions.
This chapter mainly list the contact information.
Software basic operation
Contact us
1
2
3
4

CONTENTS
4
AutoGetWifi Intelligent Fiber Endface Microscope
1 PROFILE...................................................................................................................6
2 Hardware basic operation....................................................................................9
3 Software basic functions....................................................................................14
1.1 Check the packaging..................................................................................6
1.2 Product description....................................................................................6
2.3.1 Power On/Off.........................................................................................10
2.3.2 Remove the battery..............................................................................10
2.3.3 Handle angle adjustment......................................................................11
2.3.4 Install WiFi module..............................................................................12
2.3.5 Measurement.........................................................................................12
2.3.6 Floodlight switch...................................................................................13
2.3.7 Replace the adapter.............................................................................13
2.3.8 MT adapter use.....................................................................................14
3.1.1 Device software installation and update..............................................14
3.1.2 PC software installation and update.....................................................14
3.2.1 Device software main interface...........................................................15
3.2.2 Device software measurement task setting ........................................16
3.2.3 Device softwareSettings........................................................................17
3.2.4 Device software CCD Verification.......................................................18
3.2.5 About.....................................................................................................18
3.3.1 SF measurement.....................................................................................19
3.3.2 MT measurement...................................................................................19
2.1 Features................................................................................................................9
2.2 Performance.........................................................................................................9
2.3 Hardware operation..........................................................................................10
3.1 Software installation and update......................................................................14
3.2 Device software interface.................................................................................15
3.3 Device software operation instructions............................................................19
3.3.3 Image brightness setting......................................................................25
3.3.4 CCD Verification operation..................................................................26
3.3.5 Layer.......................................................................................................27
3.3.6 Image magnification and reduction.................................................27
3.3.7 File view................................................................................................28

5
AutoGetWifi Intelligent Fiber Endface Microscope
4 Contact us.............................................................................................................31
3.3.1 SF measurement.....................................................................................19
3.3.2 MT measurement...................................................................................19
3.4.1 PC software main interface................................................................28
3.4.2 PC software settings.............................................................................29
3.4.3 PC software FTP function.....................................................................30
3.4 PC software interface.........................................................................................28
3.3.3 Image brightness setting......................................................................25
3.3.4 CCD Verification operation..................................................................26
3.3.5 Layer.......................................................................................................27
3.3.6 Image magnification and reduction.................................................27
3.3.7 File view................................................................................................28

6
AutoGetWifi Intelligent Fiber Endface Microscope
1 Profile
1.1 Check the packaging
1.2 Product description
Referring the packing list of the products, please check whether all items are contained. If there are any
missed items, please contact us immediately.
Figure1-1
Adapter interface: Connect different connectors. Nut: To fix the adaptor interface.
Floodlight LED: Assist the operation in dark conditions.
Status Indicator: Indicates the status of the device. The operating status is blue. If the measurement
passes, it is green; if the measurement fails, it is red.
Power button: Press and hold the Power Button to turn the power on.
Touch screen: Display image and software operation interface. Label: Indicates important information
about the product.
WiFi module:Support wireless transmission.
Floodlight switch: To turn floodlight LED on/off.
Measurement button:Trigger measurement. Battery slot control switch: To load and unload battery.
Label
Adapter Interface
Nut
Power Button
Status Indicator
Floodlight LED
WiFi Module
Measurement Button
Battery slot control switch
Floodlight Switch
Touch Screen

7
AutoGetWifi Intelligent Fiber Endface Microscope
Figure1-2
Figure1-3
Touch pen: For touch screens.
Handle angle adjustment button:
SD card slot: Install SD card to store data and reports.
USB interface: DC 5V, Type C
Battery status LED indicator: Displays the battery power and the storage status during the charging
process.
Handle Angle Adjustment Button
Touch Pen
SD Card Slot
USB Interface
Battery status LED
indicator

8
AutoGetWifi Intelligent Fiber Endface Microscope
Figure1-4
Light-Sensor: The screen brightness can be adjusted according to the ambient light intensity.
Touch screen: Display image and software operation interface.
Focus button: Manual focus button.
Light-Sensor
Touch Screen
Focus Button

AutoGetWifi Intelligent Fiber Endface Microscope
9
2 Hardware basic operation
2.1 Features
2.2 Performance
1.Varies of adapters meet different requirements on inspect male fiber connectorfemale fiber connector,
such as FC SC ST E2000 LCMU and TOSA ROSA fiber end-face.
2.AutoGetWiFihas high quality optical component and high resolution CCD sensor.
3.Support SD card storage.
4.Dedicated rechargeable battery, durable for 9 hours continues inspection.
5.User-friendly design, floodlight for use in dark conditions; the use of protective cover in the use of
transport process; the rubber edge design to protect from dust and damage from falling and shock.
6.The device is equipped with a quick measurement button function, which can record the measurement
of the optical fiber end face at any time by data and report and store it on the SD card.
Projects
0.92um 0.52um
1/1.8” CMOS
×5 ×8.72
______
480X800 3.2” LCD touch screen
MT Parameters Common Interface Parameters
Display
Display Frame Rate
3 levels
Operating Temp.
Storage Temp.
Relative Humidity
Weight
Dimensions
-5°C~+40°C
-20°C~+55°C
<90%(Working/Storage)
565g
281mm×201mm×57mm(foldable)341mm×67mm×57mm (straight)
4hours(charging current:2A)
25fps
1440um×1100um(Preview mode)
220um×220um(Measure mode)
620um×620um(Preview mode)
250um×250um(Measure mode)
130um×130um(Core mode)
WiFi 、USB Type C
Built-in Li-ion battery(chargeable、replaceable)
9 hours
Field of View
<1um
Auto
Resolution
Image Sensor
Optical Magnification
Image Magnification
Particle Detection
Focusing Mode
Signal Output
Power Supply
Life time
Charge Time
Charge Adapter
Accessibility
USB DC adaptor 5V/2A, including US,EU,UK,AU…adapters
With white LED environment lighting, 60° foldable body

AutoGetWifi Intelligent Fiber Endface Microscope
10
Figure2-1
Figure2-2
2.3 Hardware operation
2.3.1 Power On/Off
2.3.2 Remove the battery
To power on the device, press and hold the
power button till the blue light indicator is on.
When the battery switch is in the position shown in the figure, the
battery will automatically pop up, then gently push the battery and
then pull it out.
Battery usage:
1.Use a power supply to charge during the shutdown state of the device, and it will take about 4
hours to charge.
2.When the low light of the power indicator is flashing, the equipment needs to be recharged.
Otherwise, the equipment will be automatically shut down after a certain time. In order not to
affect the performance of the equipment and normal use, please charge in time.
3.In the recharging process, the 4 power indicators will blink in sequence. When the four lights
are always bright, the battery is fully charged.

AutoGetWifi Intelligent Fiber Endface Microscope
11
Figure2-3
2.3.3 Handle angle adjustment
Battery use precautions:
1.When in use, the battery shall be kept out from heat and high voltage. Avoid children’s
touching. Do not drop or shock the battery.
2.Do not short the battery. Do not demolish or disassemble the battery. Do not put the battery in
the damp place to avoid danger.
3.When the battery was stored for a long period, put it well in its half capacity, and charge it
again 3 months later. Do not wrap it with conduct material to avoid the damage caused by the
direct contact between the metal and battery. Keep the battery in dry places.
4.Well disposed the disused battery. Do not put it into fire or water.
5.Use the assigned chargers in the recommended operational environment only.
6.The leaking electrolyte will cause the skin uncomfortable. If it drops into eyes, do not rob the
eyes. Wash thoroughly in time, and go to hospital for treatment.
Rotate the handle when the button
is pressed.

AutoGetWifi Intelligent Fiber Endface Microscope
12
Figure2-4
Figure2-5
2.3.4 Install WiFi module
2.3.5 Measurement
Install WiFi Module
Press the measurement button to
show real-time image

AutoGetWifi Intelligent Fiber Endface Microscope
13
Figure2-6
Figure2-7
2.3.6 Floodlight switch
2.3.7 Replace the adapter
Turn on the light switch to illuminate when the outside light is dark.
Replace the adapter:
1.Loosen the lock nut of the adapter.
2. Remove the adapter.
3. Insert a new adapter.
4. Groove alignment.
5. Re-tighten the lock nut
Light on
Light off
Fasten the screw nut

14
AutoGetWifi Intelligent Fiber Endface Microscope
Figure2-8
2.3.8 MT adapter use
The rotation nut on the MT adapter marks the values 1, 2, and 3, and the mark values are aligned
with the dots, respectively, and the measurement buttons are used for image acquisition.
NOTE:
1. The installation method of the MT adapter is the same as that of the single fiber adapter.
2. The MT PC adapter is used in the same way as the MT APC adapter.
3 Software basic functions
3.1 Software installation and update
3.1.1 Device software installation and update
3.1.2 PC software installation and update
1. Copy the software that needs to be updated to the AutoGetWifidevice SD cardroot directory, and
then install the SD card to the AutoGetWifidevice card slot.
2. Start the AutoGetWifidevice and enter the Software Settings - About interface, click Upgrade.
After the upgrade is complete, it prompts you to restart the device.
3. After the reboot is complete, go to the about interface, click Restore factory settings, and follow
the prompts to restart the device. After the reboot is complete, the software update is complete.
Note:
1. If there is no updateable software in the SD card, the system will prompt "No upgradeable version
found in SD Card"
The PC software directly double-clicks the installer and installs it as prompted until the installation
is complete.

15
AutoGetWifi Intelligent Fiber Endface Microscope
Figure3-1
3.2Device software interface
Power on the device, enter the software main interface.
3.2.1 Device software main interface
Image display area: Display real-time images and measurement results.
Image sharpness:The progress bar green indicates that the image is in a clear state. Setting:
Software system settings and measurement task settings.
ID: ID number will be saved in data, report file
INC:The ID number is automatically increased after the measurement.
AF On: Auto focus switch.
Measurement results area: PASS or FAIL. Task:Measurement tasks can be selected. Save: Data or
report saving mode.
+:Image enlargement for easy viewing of end face details.
-: Image reduction ferrule visible area becomes larger.
Layer on:When the mask layer is on, the measurement result is displayed as an image; When the
layer is off, only the actual measured image is displayed.

16
AutoGetWifi Intelligent Fiber Endface Microscope
Figure3-2
3.2.2 Device software measurement task setting
Click “Setting” on the interface to enter the measurement task setting interface as follows:
Task: The default measurement task cannot be deleted or modified, and the measurement task can
be customized based on the default measurement task.
Type: Measurement task types are divided into SM, MM, SF, MF, and are selected according to
actual measurement requirements.
Scratch, defect application: After checking, the measurement function of the spot or scratch of the
current measurement area takes effect.
Sensitivity: Sensitivity can be adjusted according to the actual image conditions.
Apply: Apply the settings of the current change.
OK: Save the changed settings then exit.
Cancel: Cancel the changed settings and exit.
Task
Task name
Task type
Task zone name
Task eaiting area
Application settings
OK to save and exit
Cancel to save and exit
Edit task
Delete task
Increase task

17
AutoGetWifi Intelligent Fiber Endface Microscope
Figure3-3
3.2.3 Device softwareSettings
Click “Setting - Device” on the interface to enter the device setting interface as follows:
Image brightness: The user can adjust according to the actual image brightness, select the SF
corresponding to adjust the image brightness under the SF measurement task, and select the MF
corresponding to adjust the image brightness under the MF measurement task.
LCD brightness: Users can manually adjust according to the needs of the actual use of the scene,
or you can check the "Auto" device to automatically adjust according to the brightness of the
external environment.
If button no operate, shutdown: By default, the measurement function will not be turned off within
30 minutes, and "Never", "10 minutes" and "20 minutes" will be selected.
System Time: Displays the current time, day, month, year, hour, minute, and second.
Data and report information: company, description, operator, can be customized, you need to click
the edit button again after the customization is completed or click the apply button to save.

18
AutoGetWifi Intelligent Fiber Endface Microscope
Figure3-4
Figure3-5
3.2.4 Device software CCD Verification
3.2.5 About
Click the interface "Settings - CCD" to enter the CCD Verification interface, the purpose is to
eliminate the inherent dirty spots on the CCD.
Click “Setting - About” on the interface to enter the about interface as follows:

19
AutoGetWifi Intelligent Fiber Endface Microscope
Figure3-6
Note:
It is necessary to restart the device after restoring factory settings.
Check the software update: Before updating the software, you need to copy the installer to the SD
card, click Update, and follow the prompts to upgrade. For details, see 3.1.1.
Restore factory settings: Click Restore to restore the system settings, follow the prompts to restart.
Software version information: Displays the current software version number.
In the real-time image display state, press the device measurement button to measure. After the
measurement is completed, the measurement result is displayed. Press the measurement button
again to display the real-time image.
3.3Device software operation instructions
3.3.1 SF measurement
3.3.2 MT measurement
For image acquisition, it is necessary to match the MT adapter rotary nut mark value 1, 2, 3, and
collect in three stages, and finally display the measurement results of the MT.
The measurement steps are as follows:
Table of contents
Popular Security Sensor manuals by other brands

KWB
KWB SAFETY FIXX 011620 Instructions for use

Industrial Scientific
Industrial Scientific VX500 instruction manual

System Sensor
System Sensor CO1224 Installation and maintenance instructions

Siemens
Siemens Sinteso FDB221 product manual

Dräger
Dräger Messkopf Polytron SE Ex PR M1 DQ Instructions for use

OzSpy
OzSpy MEQC3506 quick start guide