Dosch&Amand DA1280 User manual

-1-
DA1280 cordless telephone PLUG
DECT and CAT-iq
Manual
Page
3
Start-Up with DECT GAP Base Station
4
connect analogue terminal
5
operation: telephone, Telefax
6
operation: Hints
7
switch into ex-works-setup
8
change ex-works-setup parameters: Method 1
9
Configuration Codes
10
change ex-works-setup parameters: Method 2
11
connectors, LED ,… Software Upgrade
12
Questions and Answers (FAQ)
13
Security Advices
14
Warranty
15
Recycling
16
CE Conformity

-2-
Congratulations
DA1280
represents an analogue telephony plug which setup
communication link to a DECT-Base Station. DA1280 can connect
legacy analogue terminals as corded Telephones, Fax, Answering
Machine, Modem or POS terminal via DECT to your IP Access Point.
DA1280 is compatible to all commercially used DECT-GAP-Base
Stations but also to modern DSL-VoIP-Routers, as Speedport from
Deutsche Telekom or Fritzbox, Tipel DSL VoIP Router or Internet Box
from SwissCOM.
Simply connect your analogue
terminal via RJ11 cable to DA1280
RJ11 plug. DA1280 will connect your
terminal via DECT (30meter indoor)
with your access point which
transmits your Call, Fax or Data to
your WAN destination.
All you have to do is to make your DA1280 “acquainted” with your
access point. This is called Registration and is the same procedure you
know from DECT Handsets. This manual will help you.

-3-
Start-Up with Standard DECT Base
1.
switch-on DA1280 near Base Station
2.
switch-on
Repeater Mode
of DECT Base Station
(see Manual of DECT Base Station)
3.
press „Registration“ at DECT Base Station
4.
wait till DA1280 is in operational mode
*1)
read pages 8-10 in case PIN of your DECT Base is not „0000“
Hints for PABX and Multicell Systems:
DA1280 has a unique DECT-ID called IPEI. This IPEI you can see on the product label on your
DA1280. It has is a 10-digit Hexadecimal form (HEX). Some DECT Systems (e.g. PABX) request
this PIN in decimal form (DEC).
The conversion HEX (e.g. IPEI 00092268E9) into DEC form is as follows:
convert left-sided 5 HEX digits into decimal (5-digits) e.g. 00092
HEX
in 00146
DEZ
convert residual 5 HEX digits into decimal (7-digits) e.g. 268E9
HEX
in 0157929
DEZ
IPEI 00092268E9 (HEX) is converted into 001460157929 (DEC)

-4-
connect analogue terminal
Use wall-plugs for DA1280 with
LEDs on top. Please take care
that RJ11 cable does not exceed
3 meters. Connect your
analogue terminal with RJ11
cable to DA1280. In Germany in most cases a standard TAE adapter
is necessary. You can immediately use your analogue terminal with
DA1280 ex-works-setup. See pages 8-10 if you need to adjust the
ex-works configuration.
Signalling tones
description
frequency
tone/pause
dialling tone
440 Hz
continous
occupied
440 Hz
periodically 125ms Ton, 475ms pause
special dialling tone
880 Hz
continous
positive execution signal
440 Hz
1-time 1,0 sec
negative execution signal
440 Hz
3-times 500ms ton, 250ms pause

-5-
Operation
Incoming Call
LED3 is flashing and connected terminal will be signalising incoming
call. Accept Call with terminal and LED3 stops flashing and shows LED3
active.
Outgoing Call (overlay dialling)
Hook-off analogue terminal. LED3 shows active and dialling tone will
be announced. Analogue terminal dials calling number. After 4 seconds
wait, DA1280 will setup the call with this resulting number sequence.
DA1280 is in transparent connection (ex-works-setup).
Outgoing Call (auto dialling)
DA1280 can hold a special telephone number for auto-dialling after
hook-off. This telephone number must be configured (see pages 8-10).

-6-
Operation
Hints
In case Internal Calls are enabled, you can call internal DECT handsets
with following sequence:
**{Handset INT number}#
possible {Handset INT number} are 1,2,3,5,6,7,8,9
Please notice that „Internal Call enabled“ and „transparent Mode on“
cannot be activated simultaneously.
If „transparent Mode ON” the DECT Link will be setup instantly after
hook-off. DTMF tones will be transmitted and not evaluated.
.

-7-
ex-works-setup
description
ex-works status
Fax/Modem
OFF
Internal Call
OFF
End Symbol
#
transparent Mode
OFF
Caller rights
Incoming/outgoing calls
DTMF signaling
OFF
flash time
300ms
Auto dialling
OFF
restore ex-works-setup
Press side key for 5 seconds to activate the RESET of DA1280.
RESET function will restore the ex-works setup. All previous DECT
registration will be deleted and all Settings will be reset to
ex-works parameters. After RESET, DA1280 will
automatically start searching a DECT-Base Station which is
close to his place.

-8-
change ex-works-setup
Method 1:
connect a corded analogue phone to DA1280 and use its
keypad for entering Configuration Codes. Follow the instructions below.
Activate Configuration Mode
1. disconnect DA1280 from wall plug (power OFF)
2. hook-off the phone which is connected to DA1280
3. connect DA1280 to wall plug again (power ON)
You will hear the special signalling tone.
There is also Method2 to configure your DA1280. Here you connect
DA1280 with your PC via USB cable. A special DA1280 PC Application
delivers a modern MMI for all Settings of DA1280.
Read more on page 10.

-9-
Configurations Codes
**800*1#
End of configuration
**801*{PIN}#
Registration to Base station with {PIN}
**802*1#
Fax/Modem Mode ON e
**802*0#
Fax/Modem Mode OFF
**803*1#
Internal calls enabled
**803*0#
Internal calls disabled
**804*1#
End Symbol ON = #
**804*0#
End-Symbol OFF
**805*1#
transparent Mode ON
**805*0#
transparent Mode OFF
**806*{0..2}#
Caller Rights enabled for
0: incoming and outgoing calls
1: outgoing calls 2: incoming calls
**807*1#
DTMF Signalling ON
**807*0#
DTMF Signalling OFF
**808*{DTMFsequence}#
DTMF Signalling Sequence 2-digit
**809*{DTMF tone}#
DTMF Signalling tone 1-digit
**810*{0 ..3.. 9}#
Flash Time
0: 50ms 1: 60ms 2: 80ms
3: 100ms 4: 120ms 5: 180ms
6: 250ms 7: 300ms 8: 600ms
9: 800ms
**851*{auto number}#
Auto call number , max 24-digit
**852*1#
Auto call ON
**852*0#
Auto call OFF
**899*3853171#
restore ex-works-setup
Ex-works parameters are printed
bold
.
Please close configuration mode with sequence
**800*1#
In case your DECT Base does not support PIN „0000“, repeat
Registration to Base with
**801*{PIN}#
and use PIN of DECT Base
.

-10-
change ex-works-setup
Method 2:
Connect DA1280 via USB with your PC. A special DA1280
APP (download from Internet) will offer you a comfortable MMI for all
settings of DA1280. Adapt your setup to your requirements which will
be automatically stored on DA1280 when closing the APP regularly
1. disconnect DA1280 from wall plug (Power OFF)
2. connect DA1280 to your PC via USB cable
3. download APP and start DA1280 APP
4. follow the instruction of the APP

-11-
Connectors, LED, side key
Nr
Element
1
LED1 power supply (on/off)
2
LED2 DECT Link Quality (3 colors)
3
LED3 active call in REP (on/off)
4
side key(Reset, special for multicall HS)
5
USB connector (SW Upgrade)
Software Upgrade
Software Upgrades for DA1280 can be downloaded via USB
connector and USB cable to PC. Please search your Supplier’s
website to get information about such Software Upgrades.

-12-
FAQ: Questions and Answers
Please visit also the website of your dealer and/or manufacturer to get
actualised information and FAQs about DA1280.
problem
root cause
remedy
no line, no signalling,
no dialling possible
The analoge terminal is not properly
connected to DA1280
current line is occupied by further
devices
Crosscheck cable and connectors
between DA1280 and connected
wait till line is free
No DECT Link to BASE.
DA1280 is not (properly) registrated
to DECT BASE.
LED2 (DECT LED flashes red)
DECT Base is switched OFF
Execute Registration and take
care about proper PIN of Base
Reduce the position of DA1280
to Base till LED2 = GRÜN
Switch-ON DECT Base and wait
several seconds
DECT Registration
does not work
DECT Base is not in Registration
Mode.
PIN code is wrong
Activate Registration Mode of
DECT Base .
Use Registration via
Configuration Codes
**801*{PIN}# or change OIN of
Base into -PIN auf „0000“ and
repeat Registration
You can hear Dial
signalling tone, but
dialling is not
executed.
Transparent Mode is ON .
switch >OFF Transparent Mode
via Configuration Code
**805*0#

-13-
Security Advices
Make sure your DA1280 is not exposed to heat and interference
from electrical devices e.g. motors and transformers.
DA1280 shall be not be placed close to metallic walls.
Place DA1280 in wall sockets only with LEDs on top.
Protect your DA1280 from wet conditions, dust, aggressive
liquids and acrid fumes.
Use soft and wet wipes for cleaning the product. Never use
detergents.
Only qualified and authorised service personal are allowed to
open and repair the product.
If you hand the product to further person, do not forget to hand
this manual with the product.

-14-
Warranty
Your dealer warrants for 2 years for material and manufacturing
quality of the product. Appointed date is the date of Buyer‘s receipt.
The Buyer has the right for repair or replacement.
Returned and replaced products will pass its property to the Seller.
In case of defects Buyer has to immediately inform the Seller about
such defects.
Warranty claims must be made evident via original receipt.
Any defect caused by incorrect handling, usage and caused by
physical stress or other incorrect environmental conditions are not
subject to warranty claims.

-15-
Recycling
Please contact your Dealer regarding Recycling of your
product. In no case get disposed of your product via
household garbage.
Manual for DA1280 DECT analogue PLUG
English Version 2.0 Edition 01
September 2018
Editor
DOSCH&AMAND Products GmbH Munich

-16-
CE Conformity
This Device complies with the requirements of the EU directives:
2004/108/EC (directive of the European Parliament and of the Council
on the approximation of the laws of the Member States relating to
electromagnetic compatibility and repealing Directive 89/336/EEC) and
2006/95/EC (the directive of the European Parliament and of the
Council on the approximation of the laws of the Member States relating
to electrical equipment designed for use within certain voltage limits).
The conformity with a.m. rules is confirmed by the CE sign. The CE
Conformity with the o. a. directives is confirmed by the CE mark. The
EC declaration of conformity can be viewed at the following address:
DOSCH&AMAND Products GmbH, Neumarkterst. 18, 81673 Munich
Technical Support
More technical support can be supplied via Service Number of your
Dealer Please consult the Dealer’s website for respective Tel Number.