DSE 871 Series User manual

DEEP SEA EL ECT R O N I C S
871x INST ALLATION INSTRUCTIONS
ACCESSING THE FRONT PANEL CONFIGURATION EDITOR
NOTE:
NOTE: NOTE:
NOTE:
Selected parameters can be configured via the front panel editor.
Selected parameters can be configured via the front panel editor.Selected parameters can be configured via the front panel editor.
Selected parameters can be configured via the front panel editor.
comprehensive module configuration is possible using the
comprehensive module configuration is possible using the comprehensive module configuration is possible using the
comprehensive module configuration is possible using the PC C
PC CPC C
PC C
onfiguration
onfiguration onfiguration
onfiguration
S
SS
Software
oftwareoftware
oftware.
. .
. Please contact us for further details
Please contact us for further detailsPlease contact us for further details
Please contact us for further details.
..
.
•
Ensure the engine is at rest and the module is in STOP mode by pressing the Stop/Reset
•Press the Stop/Reset and Info buttons simultaneously.
•If a module security PIN has been set, the PIN number request is then
shown :
•Press , the first ‘#’ changes to ‘0’. Press
(up) or
(down)
correct value.
•Press (right)
when the first digit is correctly entered. The digit you have just entered will now
show ‘#’ for security.
•
Repeat this process for the other digits of the PIN number. You can press
to move back to adjust one of the previous digits.
•
When
is pressed after editing the final PIN digit, the PIN is checked for validity. If the number is
not correct, you must re-enter the PIN.
•
If the PIN has been successfully entered (or the module PIN has not been
enabled), the editor is displayed :
EDITING A PARAMETER
•
Enter the editor as described above.
•
Press the left or right buttons to cycle to the section you wish to view/change.
•
Press the up
or down
buttons to select the parameter you wish to view/change within the currently
selected section.
•To edit the parameter, press
to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
•Press the up
or down
buttons to
change the parameter to the required value.
•Press to save the value. The parameter ceases
flashing to indicate that it has been saved.
•To exit the editor at any time, press and hold the button.
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
ensure
ensure ensure
ensure security.
security.security.
security.
NOTE:
NOTE: NOTE:
NOTE:
The PIN number is automatically reset when the editor is exited (manually or
The PIN number is automatically reset when the editor is exited (manually or The PIN number is automatically reset when the editor is exited (manually or
The PIN number is automatically reset when the editor is exited (manually or
a
aa
au
uu
ut
tt
to
oo
om
mm
ma
aa
at
tt
ti
ii
ic
cc
ca
aa
al
ll
ll
ll
ly
yy
y)
))
)
t
tt
to
oo
o
e
ee
en
nn
ns
ss
su
uu
ur
rr
re
ee
e
s
ss
se
ee
ec
cc
cu
uu
ur
rr
ri
ii
it
tt
ty
yy
y.
..
.
DEE P S EA EL ECT R O N I C S
871x INST ALLATION INSTRUCTIONS
053-071
ISSUE 1
Selected parameters can be configured via the front panel editor.
Selected parameters can be configured via the front panel editor.Selected parameters can be configured via the front panel editor.
Selected parameters can be configured via the front panel editor.
More
More More
More
onfiguration
onfiguration onfiguration
onfiguration
Suite
Suite Suite
Suite
Ensure the engine is at rest and the module is in STOP mode by pressing the Stop/Reset
button.
(down)
to adjust it to the
when the first digit is correctly entered. The digit you have just entered will now
Repeat this process for the other digits of the PIN number. You can press
(left) if you need
is pressed after editing the final PIN digit, the PIN is checked for validity. If the number is
If the PIN has been successfully entered (or the module PIN has not been
Press the left or right buttons to cycle to the section you wish to view/change.
buttons to select the parameter you wish to view/change within the currently
to enter edit mode. The parameter begins to flash to indicate that
change the parameter to the required value.
flashing to indicate that it has been saved.
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
NOTE: When the editor is visible it is automatically exited after 5 minutes of inactivity to
The PIN number is automatically reset when the editor is exited (manually or
The PIN number is automatically reset when the editor is exited (manually or The PIN number is automatically reset when the editor is exited (manually or
The PIN number is automatically reset when the editor is exited (manually or

ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR
•The ‘running’ editor can be entered while the engine is running. All protections remain active if
•the engine is running while the running editor is entered.
•Press and hold the button to enter the running editor.
EDITING A PARAMETER
•Enter the editor as described above.
•
Press the left or right buttons to cycle to the section you wish to view/change.
•
Press the up
or down
buttons to select the parameter you wish to view/change within the currently
selected section.
•To edit the parameter, press to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
•Press the up
or down
buttons to change the parameter to the required value.
•Press to save the value. The parameter ceases flashing to indicate that it has been saved.
•To exit the editor at any time, press and hold the button.
DIMENSIONS
240.0mm x 181.1mm x 41.7mm
(9.4” x 7.1” x 1.6”)
PANEL CUTOUT
:
220mm x 160mm
(8.7” x 6.3”)
Deep Sea Electronics Plc.
Tel:+44 (0)1723 890099
Fax: +44 (0)1723 893303
LOCALL (from UK BT landlines) :
Telephone 0845 260 8933
Web:
www.deepseaplc.com
Deep Sea Electronics inc.
Tel: +1 (815) 316-8706
Fax: +1 (815) 316- 8708
TOLL FREE (USA only) :
Telphone: 1 866 636 9703
Web: www.deepseausa.com
NOTE:
NOTE: NOTE:
NOTE: All 871x display modules are factory set to communicate via the RS232 port
All 871x display modules are factory set to communicate via the RS232 portAll 871x display modules are factory set to communicate via the RS232 port
All 871x display modules are factory set to communicate via the RS232 port
with
withwith
with
a baud rate set to
a baud rate set toa baud rate set to
a baud rate set to
115k
115k115k
115k this can
this can this can
this can
be changed via the the front panel editor.
be changed via the the front panel editor.be changed via the the front panel editor.
be changed via the the front panel editor.
Table of contents
Other DSE Monitor manuals