DV Mark DV Micro 50 User manual

v.30.october.2015

2
SAFETY INSTRUCTIONS
“To be used only
where the climate
is not tropical”
“The Lightning Flash with arrowhead symbol
within an equilateral triangle, is intended
to alert the user to the presence of uninsulated
“dangerous voltage” within the product enclosure
that may be of suf�icient magnitude to constitute
a risk of shock to persons.”
“The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the product.”
“To be used only
with altitude
not exceeding 2000 m”
1. IMPORTANT SAFETY INSTRUCTIONS
1) Read these instructions;
2) Keep these instructions;
3) Heed all warnings;
4) Follow all instructions;
5) Do not use this apparatus near water;
6) Clean only with dry cloth;
7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions;
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that
produce heat;
9) Do not defeat the safety purpose of the polarized or ground-type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet;
10) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where
they exit from the apparatus;
11) Only use attachments/accessories specified by the manufacturer;
12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from the tip-over (and Fig 21
DU Tipping Cart Symbol).
13) Unplug this apparatus during lightning storms or when unused for long periods of time;
14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped;
15) “Warning: to reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture; and objects filled with
liquids, such as vases, should not be placed on this apparatus”;
16) To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug fron the AC receptacle;
17) The mains plug of the power supply cord shall reamin readily accessible.
18) In case of voltage selector make sure the switch on the rear panel is on the correct voltage before connecting it to the AC
power, and the fuse is the right value for that voltage (This selector is not available on the 100V version).
Please change the voltage/fuse values label located near the voltage selector matching the voltage/fuse values when you
need to change the voltage of the apparatus.
19) “WARNING: this apparatus must be securely attached to the floor or wall in accordance with installation istruction. Tipping,
shaking, or rocking the machine may cause injury or death.”
MORE INFORMATION
For warranty and service information, please contact your local DV Mark distributor (contact information available at www.dvmark.it). For more technical information, please visit us at www.dvmark.it
and fill out the form on the Contact Us page. We
hope you enjoy your amplifier and use it to make great music!
1. PRÉCAUTIONS D’EMPLOI
1) Lire ces instructions;
2) Conserver ces instructions;
3) Suivre tous les conseils d’utilisations;
4) Suivre toutes les instructions;
5) Ne pas utiliser cet appareil au bord de l’eau;
6) Nettoyer uniquement avec un chiffon humide;
7) Ne pas bloquer le système de ventilation. Installer conformément aux instructions du fabricant;
8) Ne pas installer l’appareil près d’une source de chaleur tel qu’un radiateur, un fourneau, ou bien un autre appareil qui produit de
la chaleur;
9) Ne pas modifier le système de sécurité de la fiche polarisée ou de de la fiche pour les prises de terre. Une fiche polarisée a deux
broches, l’une étant plus distante de l’autre. Une fiche pour prise de terre a deux broches et une pointe pour la masse.
La broche plus distante et la pointe pour la masse ont été installées pour votre sécurité. Si la fiche fournie de rentre pas dans votre
prise de courant consulter un électricien pour la substitution;
10) Protéger le cordon d’alimentation afin qu’il ne soit pas piétiné ou écrasé tout particulièrement au niveau des fiches, des prises de
courant femelles, et des parties qui sortent de l’appareil;
11) Utiliser uniquement les accessoires recommendés par le fabricant;
12) Utilisez uniquement avec le chariot, le socle, le trépied, le support ou la table spécifiés par le fabricant ou vendu avec l’appareil.
Lorsque vous utilisez un chariot, soyez prudent lorsque vous déplacez l’ensemble chariot / appareil pour éviter toute blessure du
renversement (et la figure 21 DU Tipping panier Symbol).
13) Ne pas branché l’appareil en cas d’orage accompagné d’éclairs. Le débrancher en cas de non utilisation prolongée;
14) S’adresser à un service assistance agréé si l’appareil a subi des dommages, si le cordon d’alimentation ou la fiche a été
endommagé, si un liquide a été renversé sur l’appareil ou bien si un object est tombé dans l’appareil, si ce dernier a été exposé à
la pluie ou à l’humidité, s’il ne fonctionne pas correctement ou s’il est tombé;
15) “Avertissant: pour réduire le risque du feu ou de décharge électrique, n’exposez pas cet appareil à la pluie ou l’humidité et les
objets remplis de liquides; tels que des vases, ne devraient pas être placés sur cet appareil”;
16) Pour déconnecter totalement cet appareil du secteur, débranchez la cordon d’alimentation fiche de la prise secteur;
17) La prise de courant doit être facilement accessible.
18) En cas de sélecteur de tension s’assurer que l’interrupteur sur le panneau arrière est sur la bonne tension avant de le raccorder à
l’alimentation secteur et le fusible est la bonne valeur pour que la tension (Ce sélecteur n’est pas disponible sur la version 100V).
S’il vous plaît changer la tension / valeurs de fusibles étiquette située près du sélecteur de tension correspondant aux valeurs /
fusibles de tension lorsque vous avez besoin de changer la tension de l’appareil.
19) “AVERTISSEMENT: cet appareil doit être assujetti au plancher ou au mur conformément aux instructions d’installation.
Le fait de l’incliner, de le balancer ou de l’agiter peut causer des blessures ou la mort.”

Marco De Virgiliis
3
MARK VISION
A Word from Marco De Virgiliis
Thank you for choosing the DV MICRO 50!
To this day, no one which tried this super-micro 50W guitar amp can believe the volume and classic sound quality that it is able to give thanks to its innovative
design in a such small package.
The DV MICRO 50 features two channels with very user-friendly and effective controls, on-board reverb, XLR Line Out plus a headphone output and an a handy
mini-plug aux in jack for connecting an MP3 player to mix with your sound so you can practice anywhere and anytime you like, always with professional sound.
Its Input Special circuit is the result of several test with the most popular effects, it’s designed to perfectly interface with all the effects most used by guitarists. If
ever an amp was made for pedals, this is it!
This amp also features a Dual Voltage Switch 120V/240V to use the amp in countries with different voltages, without having to carry an external converter!
At DV Mark, we invested a lot of resouces in R&D to develope a proprietary power amp, designed to
respect and glorify the tone of your instrument.
We hope you will enjoy your new guitar amp, and we invite you to contact us any time with your comments and questions, at [email protected].
Thanks again, and good music!
We hope you will enjoy your new guitar amp, and we invite you to contact us any time with your comments and questions, at [email protected].
Thanks again, and good music!

4
1) INPUT Connect your guitar to this input using a standard ¼” shielded instrument cable. It’s also designed to perfectly interface with all the effects
most used by guitarists.
2) LEVEL This knob sets the input level, turn it up gradually until you reach your desidered volume.
3) BASS This knob controls the amount of low frequencies in your sound.
4) MID The Middle control regulates the
midrange frequencies and it is an important
part of your tone shaping.
5) HIGH The High knob controls the amount
of high frequencies in your sound.
6) DRIVE (LEAD CHANNEL) Adjusts the
amount of distortion on CH2, ranging from
crunch to overdrive sounds.
7) BASS This knob controls the amount of
low frequencies in your sound.
8) HIGH The High knob controls the amount
of high frequencies in your sound.
9) LEVEL (LEAD CHANNEL) This knob sets
the input level, turn it up gradually until you
reach your desidered volume.
10) REVERB Level control for the onboard reverb. This amp features a last generation of digital reverb, it’s sweet-sounding, warm and natural.
11) AUX Use this input to plug in an iPod, CD or MP3 player using a mini plug 1/8”. This signal mixes in evenly with your instrument input.
12) CLEAN/LEAD SWITCH This channel selector switches between the Clean and Lead channels.
Channel-switching can also be controlled by a footswitch that can be plugged into the amp’s rear panel (20).
13) PHONES For quiet practing plug headphones into this mini plug 1/8” input. You can practice anywhere and anytime you like, always with a
professional sound.
14) ON/OFF SWITCH This switch delivers AC power to the amp.
FRONT PANEL
SPEAKER OUT
MIN LOAD 4Ω
LINE OUT
FSW
VOLTAGE
120
240
1
7
2
6
5 13
4
3
89
10
11
12
14
15 16 17 18 19 20

5
15) AC POWER SOCKET Make sure the unit is grounded; all three terminals of the AC power plug must be connected to avoid any injury to the user
or damage to the unit.
16) VOLTAGE SELECTOR The DV MICRO 50 features a 120V/240V Voltage Selector to use the amp in countries with different voltages, so
make sure the switch on the rear panel is on the correct voltage before connecting it to the AC power, and the fuse is the right value for that
voltage (This selector is not available on the 100V version).
Please change the voltage/fuse values label located near the voltage selector matching the voltage/fuse values when you need to change the
voltage of the unit.
17) FSW 1/4” MONO jack for connecting a SINGLE
footswitch to switch between Clean and Lead
channels.
18) GROUND LIFT Occasionally, when you’re
playing live and using the Line Out (18), the
soundman will detect a hum from your amp’s signal.
This is often due to a ground problem related to your
power source; You will likely eliminate this hum
simply flipping the GND Lift switch.
19) LINE OUT This balanced XLR output sends a
balanced signal to the mixing console or snake in
live and studio situations. The Line Out signal is
post-EQ and post-reverb
20) SPEAKER OUT The two speaker ouputs provided for speaker cabinet connections are wired in parallel and total minimum impedance load for the
amp is 4 ohms, so you can connect one or two 8 ohms speakers or only one 4 ohms speaker.
Use speaker cable (not instrument cable)..
REAR PANEL
SPEAKER OUT
MIN LOAD 4Ω
LINE OUT
FSW
VOLTAGE
120
240
1
7
2
6
5 13
4
3
8910
11
12
14
15 16 17 18 19 20

6
Channels: Two (clean / lead)
Controls: Level (clean ch)
Drive / Level (lead ch)
EQ Controls: Bass - Mid - High (clean ch)
Bass - High (lead ch)
Speaker Outputs: Two ¼” Jacks mono out 8 ohm
Power Output: 60W @ 4ohm / 45W @ 8ohm
Other Features: Footswitch input for channels switch
AUX IN
Headphone OUT
XLR Line OUT with GND Lift
Dual Voltage selector 120V/240V
Dimensions: 200 x 64 x 221 mm / 7.87” x 2.51” x 8.7”
Weight: 1,9 kg / 4.19 lbs
POWER REQUIREMENT: 100V; 120V; 230V; 240V - 50/60Hz
BLOCK DIAGRAM
TECHNICAL SPECS
Input
Drive
Power
Power
Out
TONES
Line out
Level
Level TONES REVERB
AUX

7
NOTE

srl
Italy - 66020 San Giovanni Teatino CH - Via Po, 52
Tel: +39 0854407764 / 0854465705 - Fax: +39 0854407764 / 0854407399 - www.dvmark.it - [email protected]
www.markaudio.it
www.markbass.it
www.momark.it
Product specications are subject to change without notice
Table of contents
Other DV Mark Musical Instrument Amplifier manuals

DV Mark
DV Mark DV MICRO 50 II User manual

DV Mark
DV Mark MULTIAMP User manual

DV Mark
DV Mark q1000 Power Amp User manual

DV Mark
DV Mark Combo head 40 User manual

DV Mark
DV Mark Little 40 L34 User manual

DV Mark
DV Mark Galileo 15C User manual

DV Mark
DV Mark Little 40 II User manual

DV Mark
DV Mark Galileo 15 User manual

DV Mark
DV Mark Maragold User manual

DV Mark
DV Mark EVO 1 User manual