PRE-INSTALLATION INFORMATION
Sink dimensions (All internal measurements unless otherwise stated)
Fig.1 Width of sink minimum: 1325⁄32", Front to back of sink minimum: 1113⁄16"
Fig.2 Maximum depth of sink for Long Neck Tap (AB10) only: 7 7⁄8"
(External measurement of vessel/pedestal sink).
Fig.3 Minimum distance from tap center to top of sink (AB11 only) 315 ⁄16".
Front edge of sink (all types – pedestal, recessed, slab) to wall minimum 155⁄32".
Internal depth of sink minimum (for all taps): 315 ⁄16"
For further information please contact Dyson.
888-397-6622
[email protected]
www.dysonairblade.com
Tap mounting
The tap stem (measured from the outside diameter) should
be mounted 19⁄32" – 19⁄16" from the outside edge of the sink.
When multiple taps are installed side-by-side, tap centers
should be a minimum of 2253⁄64" apart and a minimum of
1127⁄64" from tap center to a side wall. This allows sufficient
space for mounting the motor bucket horizontally as well as
enough space for users at the sink (shoulder to shoulder).
Do not place the downward facing water sensor of the tap over
a reflective surface, such as the drainage hole. (Fig.4)
Sink specification guidelines
The Dyson Airblade Tap hand dryer is compatible with
most sink types.
Do not use plugs within the plug holes in sinks.
Due to high velocity air and water being in close proximity,
there is a chance of some water dispersion outside
the sink dimensions.
Sinks with highly polished surfaces should be avoided
e.g. reflective chrome.
Porcelain or brushed metal are ideal.
Fig.1 Fig.2
Fig.3 Fig.4
1325⁄32"minimum
1113⁄16" minimum
77⁄8" maximum
315 ⁄16" minimum
15 5⁄32" minimum
distributed by RESTROOM DIRECT 704 . 937.2673 www.RestroomDirect.com
350mm minimum
385mm minimum
300mm minimum
100mm minimum
200mm maximum
350mm minimum
385mm minimum
300mm minimum
100mm minimum
200mm maximum
350mm minimum
385mm minimum
300mm minimum
100mm minimum
200mm maximum
L N
L N
L N
For further information please contact Dyson.
888-397-6622
[email protected]
www.dysonairblade.com
Locating the soap dispenser
The infrared sensing zone for air activation extends along each
tap branch. Therefore, it is the user’s hand route to the soap
dispenser that is most important to prevent nuisance activation.
The soap dispenser should be located at least 2 23⁄64" outside the
width of the tap. This is so the user can reach around the side of
the branch.
The soap dispenser should be located at least 2 23⁄64" above
the branches so that the sensors are not activated.
It is also important to note that the user may reach diagonally
across for the soap and this path must not go through the
sensing zone.
Mounting the motor bucket (AB09/AB10)
The motor bucket cannot be mounted upside down.
The motor bucket cannot be installed above the sink.
315⁄16" minimum clearance from bottom of motor bucket
to floor/wall.
Only the following is advised.
Mounting the motor bucket (AB11)
Metal enclosure assembly
This Dyson product is designed so the motor unit is located
behind the stud wall. The vertical wall studs must be constructed
so as to allow the metal enclosure to be fitted between them.
One of the horizontal wall studs must be fitted a) so it holds the
main weight of the metal duct and the unit, and b) so it is in the
correct position for the tap stem.
Front on view showing
soap dispenser
clear zone.
Over head view
showing soap
dispenser clear zone.
223⁄64"223⁄64"
223⁄64"
223⁄64" 223⁄64"
223⁄64"
315⁄16"
315 ⁄16"
315 ⁄16"minimum
distributed by RESTROOM DIRECT 704 . 937.2673 www.RestroomDirect.com
For further information please contact Dyson.
888-397-6622
[email protected]
www.dysonairblade.com
Tools required
To install this unit you will need (4) screws, and appropriate fittings
Torx T15 screw driver – long handle
Electrical drill with 13⁄8" drill bit
Qty 4 Raw plugs (suitable for wall type fixing to)
7mm flat head screwdriver
Flat terminal block screwdriver
Tap spanner
Spanner 11⁄2"
Sharp knife/blade
Pan head screws. Size 13 ⁄64" dia toggle or masonry type
Conduit as per local electrical regulations
Electrical
Input voltage/Frequency: 220-253V 50 Hz
Isolated by switch fuse spur or RCD as appropriate
Current 6.6 Amps
Cable spec 3 core PVC 1.5mm cross sectional area
Local electrical regulations must be adhered
to when installing or repairing the product
Rated power: 1600 W
Operating temperature range: 32° – 104°F
Standby power consumption: Less than 0.5 W
Water operation
Water flow rate: 4 l/min
Water temperature control: Thermostatic mixer recommended (not supplied)
Water pressure required: 1-8 Bar
1 ½" BSP isolated valve required for service
Water supply cleanliness and biological growth
In some countries there are regulations or guidelines that require
temperature controlled water supply systems (such as that supplied
to the Dyson Airblade Tap hand dryer) to be subjected to regular
cleaning to minimize any biological growth.
To enable you to meet these regulations, the Dyson Airblade Tap
hand dryer has been designed and tested to withstand internal
cleaning both with hot water up to 203°F and with sodium hypochlorite
at a concentration of 0.45%.
Dyson is unable to advise regarding the details of the cleaning
you should carry out because this will be specific both to the
applicable regulations and to your water supply system.
When carrying out internal cleaning of the Dyson Airblade Tap
hand dryer, please be aware of any safety considerations when
using hot water or chemicals. Dyson will not be responsible
for any injury caused by this process.
Abusive testing
The tap has undergone rigorous abusive testing
to ensure that it can withstand substantial forces
and impacts typical of a commercial and public
bathroom environment.
distributed by RESTROOM DIRECT 704 . 937.2673 www.RestroomDirect.com

This manual suits for next models

2

Popular Kitchen & Bath Fixture manuals by other brands

RUVATI RVH9742 quick guide

RUVATI

RUVATI RVH9742 quick guide

VADO Victoriana Installation & maintenance instructions

VADO

VADO Victoriana Installation & maintenance instructions

Bradley Express GLX Series Installation

Bradley

Bradley Express GLX Series Installation

Hans Grohe Ecostat Square 15714700 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Ecostat Square 15714700 Instructions for use/assembly instructions

Sanela SLUN 62ESB Instructions for use

Sanela

Sanela SLUN 62ESB Instructions for use

Hans Grohe Focus 31930000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Focus 31930000 Instructions for use/assembly instructions

ABI INTERIORS 11939 installation guide

ABI INTERIORS

ABI INTERIORS 11939 installation guide

Kohler Beitou 99856T-4 installation instructions

Kohler

Kohler Beitou 99856T-4 installation instructions

ZURN Camaya Series Installation, operation, maintenance and parts manual

ZURN

ZURN Camaya Series Installation, operation, maintenance and parts manual

METHVEN Aio AOBCP installation guide

METHVEN

METHVEN Aio AOBCP installation guide

Hans Grohe AXOR Montreux 16581 1 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe AXOR Montreux 16581 1 Series Installation/User Instructions/Warranty

Moen STo S62308 installation guide

Moen

Moen STo S62308 installation guide

PEERLESS P99694LF manual

PEERLESS

PEERLESS P99694LF manual

Graff G-8027 L1 Series installation instructions

Graff

Graff G-8027 L1 Series installation instructions

Spectrum Brands Pfister Avalon R89-XCB Maintenance & Care Guide

Spectrum Brands

Spectrum Brands Pfister Avalon R89-XCB Maintenance & Care Guide

KWC VITA 12.281.031.000FL Installation and service instructions

KWC

KWC VITA 12.281.031.000FL Installation and service instructions

BELLOSTA Ludo 7300/1/P Installation instruction

BELLOSTA

BELLOSTA Ludo 7300/1/P Installation instruction

Hans Grohe Allegra Carlton 14882 Series quick start guide

Hans Grohe

Hans Grohe Allegra Carlton 14882 Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.