D4800 Sentient Technical Manual – D4800TM/09G/v1 7
4. User Operation Zone Omit
The Dycon Sentient D4800 alarm system has a zone omit feature (if programmed).
Depending upon programming, a zone(s) may be omitted for a pre-set time (between 1 and
98 minutes) or may be omitted for an unlimited time.
If the “Zone Omit” feature is programmed, then its operation is as below:
1. With the Dycon Sentient D4800 armed, enter into an active zone. The external siren
will come on for 4 seconds (it will give audible warning of zone detection over the
whole installation).
2. You now have the normal “Entry Time” to press the 3rd (middle) button on the hand-
held controller.
a. If this button is pressed the zone entered will be omitted for the programmed time
or continually (depending upon the NVM programming).
b. If this button is NOT pressed within the “Entry Time” a “Full Alarm” condition will
be generated.
3. When a zone/s has been omitted, a “Common Omit timer “will be running. Thirty
seconds before the “Omit” time runs out (and zone/s becomes active again), the
external siren will come on and generate a reminder signal for 4 seconds (to give
audible warning of zone/s becoming active again). NOTE: If “Un-Timed Omit” is
programmed then a reminder signal will not be generated.
a. The user is to leave the omitted zone/s and they will become active again (see
paragraph 7 notes)
or
b. The user is to press the 3d controller button again which will restart the “Common
Omit” timer and leave all the omitted zone/s de-activated.
4. If a zone is already omitted and another zone is entered, then steps 1 and 2 will be
repeated. If action 2A is taken, this new zone will be omitted in addition to any
previously omitted zone/s. The “Omit” timer will be reset to the full time for ALL
zones.
5. The user may make ALL omitted zones instantly active by pressing the “Full Arm”
button on the controller (from outside the protected area/s). See paragraph 7 notes.
6. If the Dycon Sentient D4800 is turned from active to standby, then made active
again, ALL zones will become fully active i.e. the “normal” arming mode.
NOTES:
a. When the system tries to become fully active (time out or user pressing “Full Arm”
button) and if a fault is present, the Dycon Sentient D4800 system will go to step 2, if
the faulty zone/s are not omitted by the end of the entry time, then a full alarm will be
generated.
b. When zones are omitted a tamper condition on any omitted zone to be treated as a
full alarm.
c. Any number of zones may be omitted at the same time. If the system generates a full
alarm, but the siren has stopped and the panel has NOT been reset, when a user
enters a zone, that zone/ s may be omitted without any problems. However when the
system attempts to fully re-arm (from zone omit time out or user pressing the full set
button), it will operate as Note A above.