Eaton FT1455-L3 User manual

FT1455-L3 Hand Launcher Operating Instructions

2EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Figure 1
Nozzle
Pneumatic
Connection
Trigger
Capabilities
• Cleaning size range: 1/8” through 3-1/4”. (Can clean hoses
larger than 3-1/4” upto 4-1/2” with optional 4-1/2” nozzle)
Specifications
• Weight: 3.3 Pounds. (1.496kg).
• Pneumatic Requirements:
1/2” NPT Air Line.
80 P.s.i. - 110 P.s.i. (5.5 - 7.5 Bar) maximum.
Clean, dry, filtered air or inert gas source is required.
5 micron filter and regulator with gauge
are recommended.
Table of Content
General Information 3
Safety Instructions 3
Installation 3
Maintenance 3
Preparation 3
Operation 5
Nozzle and Projectile Selection Chart 6
Tube Sizing Chart - Nominal Inch 7
Recommended Sizing Chart - Metric tubing 8
Pipe Sizing Chart 9
Contact Information 10

3EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Preparation
Step 1: Nozzle and projectile selection
Select nozzle and projectile from Nozzle and Projectile selection
charts on pages 6, 7, 8 and 9.
Step 2: Nozzle installation
Remove the locking ring from the firing head by rotating ring
clockwise. (See Figure 2 & 3)
General Information
The Eaton’s FT1455-L3 Hand Held Launcher was designed to
shoot a projectile through hose and tube assemblies to strip out
internal contamination such as rubber dust and metal particles
from cutting processes, metal flash from crimping operations,
and contaminated oil from hoses and tubes in hydraulic systems.
Eaton Hose Cleaning Systems reduce downtime, extends filter
life and reduces the risk of failure and premature wear due to
contamination.
The purpose of this manual is to present the basic operating and
safety information for the Eaton FT1455-L3 Hand Held Projectile
Launcher.
Safety Instructions
Read and understand the operator’s manual before
attempting to operate this unit. Failure to follow
operating instructions could result in personal injury or
property damage.
Prevent Unauthorized Operation: Do not permit anyone
to operate this unit unless they have read and thoroughly
understand this manual.
Wear Safety Glasses: Risk of eye injury! Eye protection is
required at all times during the installation and operation
of this unit. Failure to wear safety glasses could result in
personal injury.
Keep work area clean. Cluttered areas and benches
invite accidents.
Never point or fire the unit in the direction of any person.
Do not attempt to dislodge a projectile from the
Hand Held Launcher when air supply is connected to
the launcher.
Do not place any objects into the launching nozzle
other than Eaton Projectiles.
Launcher and projectiles are only to be used for
cleaning hose and tubes rated for at least 110 P.s.i.
Installation
When installing the hand held projectile launcher make sure you
have a filtered and regulated air or inert gas source. Note: Never
Use Oxygen. A 1/2” NPT regulator with gauge and a 5 micron air
filter should be installed in the supply line to ensure clean
dry air.
Maintenance
Visually inspect Hand Launcher for accumulation of particulate
and oil from inlet air source. Clean as needed. Keep the hose
assembly area clean to reduce recontamination of hose, tube
and pipe assemblies.
Figure 3
Figure 2

4EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Install the required nozzle and adapter ring for application. The
adapter ring if needed, snaps into the face plate first.
(See Figure 3 & 4).
Step 3: Projectile Installation
Insert projectile into the nozzle, reattach locking ring to the firing
head by rotating ring counterclockwise. (See Figure 5 & 6).
Note: Failure to secure locking ring may cause serious injury to the operator
and or damage to the launcher. (See Figure 7).
Figure 5
Figure 4 Figure 6
Figure 7

5EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Step 4: Operation
Place the hose, tube or pipe against the nozzle to insure a good
air seal. Depress the trigger until the projectile exits the opposite
end of the hose, tube or pipe you are cleaning.
(See Figure 8).
Figure 9
Figure 8
Step 5:
Inspect projectile for contamination after firing through hose,
tubing or pipe. Several projectiles may need to be fired to
thoroughly remove contaminates. (See Figure 9).

6EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Nozzle and projectile selection chart
Figure 10
Figure 11
**Use larger recommended Eaton Projectiles when
cutting hose with an abrasive wheel. The above sizes are
recommendations. Due to different types of fittings, and the
amount ofcontamination in the line, the size projectile may need
to be adjusted.
Recommnedation for Hoses
Nominal Daimeter
Inches mm Nozzle Part # Cleaning projectile part #
3/16 05 FT1455-N-H06 FT1355-H-06
¼ 06 FT1455-N-H06 FT1355-H-10 or FT1355-H-12
5/16 08 FT1455-N-H08 FT1355-H-12 or FT1355-H-14
3/8 10 FT1455-N-H10 FT1355-H-14 or FT1355-H-16
½ 13 FT1455-N-H13 FT1355-H-18 or FT1355-H-20
5/8 16 FT1455-N-H16 FT1355-H-22
¾ 19 FT1455-N-H19 FT1355-H-26
1 25 FT1455-N-H25 FT1355-H-33 or FT1355-H-36
1-1/4 32 FT1455-N-H32 FT1355-H-40 or FT1355-H-45
1-1/2 38 FT1455-N-H38 FT1355-H-50 or FT1355-H-55
2 50 FT1455-N-H50 FT1355-H-60 or FT1355-H-65
2-1/2 63 FT1455-N-U55 FT1355-H-75
3 76 FT1455-N-U55 FT1355-H-85
3-1/2 89 FT1455-N-U55 FT1355-H-100
4 102 FT1455-N-45
4-1/2 114 FT1455-N-45
Recommendations for hose assemblies with ORS ttings
ORS
tting
dash
size Nozzle Part #
Cleaning Projectile
Part #
-4 FT1455-4FFORX FT1355-H-06 OR FT1355-H-07
-6 FT1455-N-H06 FT1355-H-12
-8 FT1455-N-H10 FT1355-H-16
-10 FT1455-N-H13 FT1355-H-22
-12 FT1455-N-H16 FT1355-H-26
-16 FT1455-N-H19 FT1355-H-33
-20 FT1455-N-H25 FT1355-H-40
Recommendations for projectiles for hose assemblies
with JIC ttings
JIC Fitting
dash Size Nozzle Part #
Cleaning Projectile
part #
-4 FT1455-J-06 FT1355-H-06 OR FT1355-H-07
-6 FT1455-J-10 FT1355-H-12
-8 FT1455-J13 FT1355-H-16
-10 FT1455-J16 FT1355-H-22
-12 FT1455-J-19 FT1355-H-26
-16 FT1455-J-25 FT1355-H-33
-20 FT1455-J-32 FT1355-H40
-24 FT1455-J-38 FT1355-H-50
-32 FT1455-J-50 FT1355-H-60
Figure 13
Recommendations for hose assemblies with
code 61 or 62 anges
Code 61 or 62
ange dash Size Nozzle Part #
Cleaning Projectile
part #
-8 FT1455-H-10 FT1355-H-16
-10 FT1455-H-13 FT1355-H-22
-12 FT1455-H-16 FT1355-H-26
-16 FT1455-H-19 FT1355-H-33
-20 FT1455-H-25 FT1355-H-40
-24 FT1455-H-32 FT1355-H-50
-32 FT1455-H-38 FT1355-H-60
Figure 12

7EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Tubing must be deburred prior to firing projectiles. Depending
on the type of contamination present in the tube, abrasive
projectiles may be used to remove rust and scale. Always use
an Eaton projectile after the use of an abrasive projectile. Tube
projectiles should be used to remove mandrel lubricants, grease
and oil.
Tube sizing chart - Nominal inch
Figure 14
Recommended nozzles and cleaning projectiles for tubes (inch)
Outside Diameter x
Wall thickness
Nozzle
part #
Cleaning Projectile
part #
Abrasive Projectile
part #
Tube Projectile
part #
1/8" X .030" FT1455-NT-03 -- -
¼" X .035" FT1455-NT-06 FT1355-H-10 FT1355-A-07 FT1355-T-06
¼" X .049" FT1455-NT-06 FT1355-H-08 FT1355-A-07 FT1355-T-06
¼" X .065" FT1455-NT-06 FT1355-H-07 - FT1355-T-06
5/16" X .035" FT1455-NT-08 FT1355-H-12 FT1355-A-10 FT1355-T-07
3/8" X .035"-.049" FT1455-NT-10 FT1355-H-14 FT1355-A-12 FT1355-T-10
3/8" X .065" FT1455-NT-10 FT1355-H-12 FT1355-A-10 FT1355-T-10
½" X .035" FT1455-J-13 FT1355-H-16 FT1355-A-16 FT1355-T-14
½" X .049" FT1455-J-13 FT1355-H-16 FT1355-A-16 FT1355-T-12
½" X .065" FT1455-J-13 FT1355-H-16 FT1355-A-14 FT1355-T-12
½" X .083" FT1455-J-13 FT1355-H-14 FT1355-A-12 FT1355-T-12
5/8" X .049" FT1455-J-16 FT1355-H-22 FT1355-A-20 FT1355-T-16
5/8" X .065" FT1455-J-16 FT1355-H-20 FT1355-A-18 FT1355-T-16
5/8" X .083" FT1455-J-16 FT1355-H-20 FT1355-A-18 FT1355-T-14
¾" X .049"-.065" FT1455-J-19 FT1355-H-26 FT1355-A-24 FT1355-T-20
¾" X .095" FT1455-J-19 FT1355-H-22 FT1355-A-20 FT1355-T-18
7/8" X .049" FT1455-J-25 FT1355-H-33 FT1355-A-30 FT1355-T-26
7/8" X .065" FT1455-J-25 FT1355-H-30 FT1355-A-28 FT1355-T-22
7/8" X .095" FT1455-N-H16 FT1355-H-28 FT1355-A-26 FT1355-T-22
1" X .065" FT1455-J-32 FT1355-H-33 FT1355-A-30 FT1355-T-28
1" X .083"-.095" FT1455-J-32 FT1355-H-33 FT1355-A-30 FT1355-T-26
1" X .120" FT1455-J-32 FT1355-H-30 FT1355-A-28 FT1355-T-26
1-1/4" X .065" FT1455-NT-32 FT1355-H-40 FT1355-A-40 FT1355-T-33
1-1/4" X .083" FT1455-NT-32 FT1355-H-40 FT1355-A-36 FT1355-T-33
1-1/4" X .095" FT1455-NT-32 FT1355-H-40 FT1355-A-36 FT1355-T-33
1-1/4" X .109" FT1455-NT-32 FT1355-H-36 FT1355-A-36 FT1355-T-33
1-1/4" X .120" FT1455-NT-32 FT1355-H-36 FT1355-A-33 FT1355-T-33
1-1/2" X .065"-.120" FT1455-J-38 FT1355-H-50 FT1355-A-45 FT1355-T-40
1-1/2" X .134"-.148" FT1455-J-38 FT1355-H-45 FT1355-A-40 FT1355-T-40
2" X .065"-.120" FT1455-J-50 FT1355-H-60 FT1355-A-55 FT1355-T-50
2" X .134"-.188" FT1455-J-50 FT1355-H-55 FT1355-A-50 FT1355-T-50
1-1/2" X .134"-.148" FT1455-J-38 FT1355-H-45 FT1355-A-40 FT1355-T-40
2" X .065"-.120" FT1455-J-50 FT1355-H-60 FT1355-A-55 FT1355-T-50
2" X .134"-.188" FT1455-J-50 FT1355-H-55 FT1355-A-50 FT1355-T-50

8EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Tubing must be deburred prior to firing projectiles. Depending
on the type of contamination present in the tube, abrasive
projectiles may be used to remove rust and scale. Always use an
Eaton projectile after the use of an abrasive projectile.
Recommended sizing chart - Metric tubing
Figure 15
Recommended nozzles and cleaning projectiles for tubes (metric)
Outside
Diameter
x Wall
Thickness Nozzle part #
Cleaning
projectile
part #
Abrasive
projectile
part #
Tube
projectile
part #
Outside
Diameter x
Wall
Thicness Nozzle part #
Cleaning
projectile
part #
Abrasive
projectile
part #
Tube
projectile
part #
6 X 1.0 FT1455-NT-06x1.5 FT1355-H-07 FT1355-A-06 FT1355-T-06 20 X3 FT1455-NT-20x3.0 FT1355-H-22 FT1355-A-20 FT1355-T-18
6 X 1.5 FT1455-NT-06x1.5 FT1355-H-07 FT1355-A-06 #N/A 22 X1 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26
8 X 1.0 FT1455-NT-08x1.5 FT1355-H-10 FT1355-A-07 FT1355-T-07 22 X1.5 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26
8 X 1.5 FT1455-NT-08x1.5 FT1355-H-10 FT1355-A-07 FT1355-T-07 22 X2 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26
10 X 1.0 FT1455-NT-10x1.5 FT1355-H-14 FT1355-A-12 FT1355-T-12 25 X2 FT1455-NT-25x3.0 FT1355-H-33 FT1355-A-30 FT1355-T-28
10 X 1.5 FT1455-NT-10x1.5 FT1355-H-14 FT1355-A-12 FT1355-T-12 25 X2.5 FT1455-NT-25x3.0 FT1355-H-30 FT1355-A-28 FT1355-T-26
12 X 1.0 FT1455-NT-12x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 25 X3 FT1455-NT-25x3.0 FT1355-H-30 FT1355-A-28 FT1355-T-26
12 X 1.5 FT1455-NT-12x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 28 X2 FT1455-NT-28x2.5 FT1355-H-36 FT1355-A-33 FT1355-T-33
12 X 2.0 FT1455-NT-12x2.0 FT1355-H-14 FT1355-A-12 FT1355-T-12 28 X2.5 FT1455-NT-28x2.5 FT1355-H-36 FT1355-A-33 FT1355-T-30
14 X 1.0 FT1455-NT-14x2.0 FT1355-H-18 FT1355-A-16 FT1355-T-16 30 X2 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-33
14 X 1.5 FT1455-NT-14x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 30 X2.5 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30
14 X 2.0 FT1455-NT-14x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 30 X3 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30
15 X 1.0 FT1455-NT-15x2.0 FT1355-H-20 FT1355-A-18 FT1355-T-16 30 X4 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30
15 X 1.5 FT1455-NT-15x2.0 FT1355-H-18 FT1355-A-16 FT1355-T-16 35 X2 FT1455-NT-35x3.0 FT1355-H-45 FT1355-A-40 FT1355-T-40
15 X 2.0 FT1455-NT-15x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 35 X3 FT1455-NT-35x3.0 FT1355-H-40 FT1355-A-36 FT1355-T-36
16 X 1.0 FT1455-NT-16x2.5 FT1355-H-22 FT1355-A-20 FT1355-T-18 35 X4 FT1455-N-H25 FT1355-H-40 FT1355-A-36 FT1355-T-33
16 X 1.5 FT1455-NT-16x2.5 FT1355-H-20 FT1355-A-18 FT1355-T-16 35 X5 FT1455-N-H25 FT1355-H-36 FT1355-A-33 FT1355-T-30
16 X 2.0 FT1455-NT-16x2.5 FT1355-H-18 FT1355-A-16 FT1355-T-16 38 X2.5 FT1455-NT-38x5.0 FT1355-H-50 FT1355-A-45 FT1355-T-40
16 X 2.5 FT1455-NT-16x2.5 FT1355-H-16 FT1355-A-14 FT1355-T-14 38 X3 FT1455-NT-38x5.0 FT1355-H-50 FT1355-A-45 FT1355-T-40
18 X 1.0 FT1455-NT-18x2.5 FT1355-H-24 FT1355-A-22 FT1355-T-20 38 X4 FT1455-NT-38x5.0 FT1355-H-45 FT1355-A-40 FT1355-T-40
18 X 1.5 FT1455-NT-18x2.5 FT1355-H-24 FT1355-A-20 FT1355-T-18 38 X5 FT1455-NT-38x5.0 FT1355-H-40 FT1355-A-36 FT1355-T-36
18 X 2.0 FT1455-NT-18x2.5 FT1355-H-22 FT1355-A-20 FT1355-T-18 42 X2 FT1455-NT-42x3.0 FT1355-H-55 FT1355-A-50 FT1355-T-50
18 X 2.5 FT1455-NT-18x2.5 FT1355-H-20 FT1355-A-18 FT1355-T-16 42 X3 FT1455-NT-42x3.0 FT1355-H-50 FT1355-A-50 FT1355-T-45
20 X 1.5 FT1455-NT-20x3.0 FT1355-H-26 FT1355-A-24 FT1355-T-22 50 X3 FT1455-NT-50x5.0 FT1355-H-60 FT1355-A-55 FT1355-T-55
20 X 2.0 FT1455-NT-20x3.0 FT1355-H-24 FT1355-A-22 FT1355-T-20 50 X5 FT1455-NT-50x5.0 FT1355-H-55 FT1355-A-55 FT1355-T-50
20 X2.5 FT1455-NT-20x3.0 FT1355-H-24 FT1355-A-20 FT1355-T-18 50 X6 FT1455-NT-50x5.0 FT1355-H-55 FT1355-A-50 FT1355-T-50

9EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E May 2015
Abrasive projectiles may be used when there is a build-up of
contamination, surface rust or scale. For pipe applications where
there is a greater build-up of contamination, surface rust or
scale, use a grinding projectile. Pipe must be straight for this
projectile.
NOTE: To ensure cleanliness, an Ultra Clean projectile must be used after abrasive.
Please call if you need help in sizing your application for the correct nozzles and
projectiles.
Pipe sizing chart
Figure 16
Recommended nozzles and cleaning projectiles for pipes (inch)
SCH 40 Nozzle part # Cleaning Projectile part # Abrasive Projectile part #
1/4" FT1455-N-H08 FT1355-H-14 FT1355-A-12
3/8" FT1455-N-H13 FT1355-H-18 FT1355-A-16
1/2" FT1455-N-H16 FT1355-H-20 FT1355-A-18
3/4" FT1455-N-H19 FT1355-H-30 FT1355-A-26
1" FT1455-N-H25 FT1355-H-36 FT1355-A-33
1-1/4" FT1455-N-H32 FT1355-H-45 FT1355-A-40
1-1/2" FT1455-N-H38 FT1355-H-55 FT1355-A-50
2" FT1455-N-H50 FT1355-H-65 -
2-1/2" FT1455-N-U55 FT1355-H-75 -
3" FT1455-N-U55 FT1355-H-85 -
3-1/2" FT1455-N-U55 FT1355-H-100 -
SCH 80 Nozzle
part
# Cleaning Projectile part # Abrasive
Projectile
part
#
1/4" FT1455-N-H06 FT1355-H-12 FT1355-A-10
3/8" FT1455-N-H10 FT1355-H-16 FT1355-A-14
1/2" FT1455-N-H13 FT1355-H-20 FT1355-A-16 or FT1355-A-18
3/4" FT1455-N-H19 FT1355-H-26 FT1355-A-22
1" FT1455-N-H25 FT1355-H-36 FT1355-A-30
1-1/4" FT1455-N-H32 FT1355-H-45 FT1355-A-40
1-1/2" FT1455-N-H38 FT1355-H-50 FT1355-A-45
2" FT1455-N-H38 FT1355-H-60 FT1355-A-55
2-1/2" FT1455-N-H50 FT1355-H-70 -
3" FT1455-N-U55 FT1355-H-85 -
3-1/2" FT1455-N-U55/90 FT1355-H-110 FT1355-A-110
4" FT1455-N-4.5LN FT1355-H-115 FT1355-A-110
SCH 160 Nozzle part # Cleaning
Projectile
part
# Abrasive Projectile part #
1/2" FT1455-N-H10 FT1355-H-16 FT1355-A-14
3/4" FT1455-N-H16 FT1355-H-20 FT1355-A-18
1" FT1455-N-H19 FT1355-H-30 FT1355-A-26
1-1/4" FT1455-N-H25 FT1355-H-36 FT1355-A-33
1-1/2" FT1455-N-H32 FT1355-H-45 FT1355-A-40
2" FT1455-N-H38 FT1355-H-55 FT1355-A-45 or FT1355-A-50
2-1/2" FT1455-N-H50 FT1355-H-65 FT1355-A-60
3" FT1455-N-U55 FT1355-H-75
4" FT1455-N-U55 FT1355-H-100

Eaton
Hydraulics Business USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Business Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacific
Eaton Building
No.7 Lane 280 Linhong Road
Changning District,
Shanghai 200335 China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 2230 7240
© 2015 Eaton
All Rights Reserved
Printed in USA
Document No. E-HOAI-CC003-E
May 2015
Assembly Equipment
Technical Support | Service | Spare Parts
www.EatonCrimperSupport.com
1-888-AT-LOMAR
(1-888-285-6627)
(517-563-8800)
Table of contents
Other Eaton Power Tools manuals

Eaton
Eaton MBS-I2 Manual

Eaton
Eaton DILH1400/22 Manual

Eaton
Eaton ET1280 User manual

Eaton
Eaton COOPER POWER SERIES User manual

Eaton
Eaton FT1455-L2 User manual

Eaton
Eaton Series NRX User manual

Eaton
Eaton 380 VCP-W 16 Programming manual

Eaton
Eaton Series NRX User manual

Eaton
Eaton CM52 Manual

Eaton
Eaton ET1187 User manual