can be integrated also in existing heating systems parallel with solid fuel boiler (exemplary
diagrams are shown on Fig. 1 and 2 page 10). It is recommended for safer operation the
electric boilers to be mounted in systems operating with a pump securing enforced
circulation of the heat medium.
3. TECHNICAL DESCRIPTION OF THE BOILER
Structure of the electric boiler/ module, see Fig. 3 page 11, Fig. 4 page 12.
Equipment of the boilers’ models is shown in Tab. 6 page 15.
Technical datas, technical characteristics and dimensions, see Tab. 1, 2, 3, 4 page 14
and Tabl. 5 page 15.
4. SYSTEM CONTROL
The three stage control performs its functions by effecting on the heaters and the water
pump of the boiler. It is proportionately control of the water temperature in the water
container according to the difference between the set temperature and the current
temperature in the heating place.
4.1. PRINCIPLE OF OPERATION
The Boiler Control System consists of main board - pos.1, room thermo regulator - pos.2,
control panel - pos.4, and other components mounted on the boiler's body. The power relays,
power supply and the electrical terminals for connection with the other components are
placed on the main board. The room thermo regulator measures the room temperature and
sends an electrical signal to the main board which corresponds to the difference between the
set and the measured temperature. This signal is in the 4 - 20 mA range. Because both the
regulators (room and boiler) are interconnected in cascade system, this signal goes as a
setpoint at the boiler thermo regulator's input which in turn controls the temperature of the
water in the boiler, therefore the more the room temperature approaches the set point of the
room thermo regulator, the less the setpoint of the boiler thermo regulator will be. In order to
maintian the water temperature in the boiler a three stage proportional regulator is
implemented. This provides smooth load of the electrical grid and also eliminates the
possibility for temperature overshoot. The purpose of this is saving electrical energy /that is
the temperature of the water in the boiler is maintained at such level that it only covers the
heat loss in the premises.
The control panel consists of button - pos.10 (X/W), LED indicaton - pos.11 and LED
indicators for the boiler condition - pos. 5,6,7
The LED indication, pos. 11 shows two temperatures. If the button, pos. 10, is pressed the
set temperature “W” of the water in the water container is shown. If the button is not pressed
the current temperature “X” of the water in the water container is shown. If the LED
indiocator, pos. 9 is switched on this means that the circulation pump is working. When the
heating is over the pump switches off after 3 minutes period.
The LEDindicator, pos 8, shows that blocking thermostat is switched on. When the cause is
eliminated, the block system is recovered manually. The control panel connects to the main
board by a 20 wire cable through the cuplung X5.