Ego Power+ PPCX1000 User manual

OPERATOR'S MANUAL
56-VOLT LITHIUM-ION
TELESCOPIC POWER POLE
MODEL NUMBER PPX1000
EN 56-Volt telescopic power pole 4
DE Ausziehbare 56-v-antriebswelle 10
FR Taille-haie télescopique 56 volts 16
ES Conjunto de motor telescópico de 56 voltios 22
PT Haste telescópica elétrica de 56 volts 28
IT Asta motore telescopica da 56 volt 34
NL 56 Volt telescopische elektrische paal 40
DK 56 V strømforsynet teleskopstang 46
SE 56-Volt teleskopmotorenhet 51
FI 56 voltin akulla varustettu teleskooppivarsi 57
NO 56-volts teleskopisk kraftstolpe 63
RU Телескопический приводной блок 56 В69
PL Teleskopowy drążek zasilający 56 woltów 76
CZ 56 voltová teleskopická pohonná tyč83
SK 56-Voltová teleskopická pohonná tyč89
HU 56 V-os teleszkópos meghajtófej 95
RO Tijăde alimentare telescopicăde 56 volți 102
SL Teleskopska napajalna palica s 56 volti 108
LT 56 voltųelektrinėgalvutėsu sustumiamu kotu 114
LV 56 voltu teleskopiskāpagarinājuma instrumentgalva120
GR Τηλεσκοπικό κοντάρι ισχύος 56 volt 126
TR 56-Volt elektrikli teleskobik sap 133
ET 56-voldine teleskooptoitepea 139
UK 56-вольтна телескопічна приводна штанга 145
BG 56-Волта литиево-йонна безкабелна
захранваща глава 151
HR Teleskopski pogonski štap od 56 V 158
KA 56ვოლტზემომუშავეტელესკოპური
ელექტრულიძელი 164
SR Teleskopska pogonska šipka od 56 Volti 173
BS Teleskopska pogonska šipka 56 V 179
HE
185
AR
190
TELESCOPIC POLE SERIES
MNL_EGO_PPX1000_EV01.31_201210

B
C D
1 3 4 5 6
789
12 14 17
16
15
13
2
1011
A
B-1
B-4
D-1
B-2 B-3
B-5
D-2

E
G
I
F
H
J
K L
E-1
E-2
1
2

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX10004
EN READ ALL INSTRUCTIONS!
READ OPERATOR’S MANUAL
Residual risk! People with electronic devices, such
as pacemakers, should consult their physician(s) before
using this product. Operation of electrical equipment
in close proximity to a heart pacemaker could cause
interference or failure of the pacemaker.
WARNING: To ensure safety and reliability, all repairs
and replacements should be performed by a qualified
service technician.
SAFETY SYMBOLS
The purpose of safety symbols is to attract your attention to
possible dangers. The safety symbols and the explanations
with them deserve your careful attention and understand-
ing. The symbol warnings do not, by themselves, eliminate
any danger. The instructions and warnings they give are no
substitutes for proper accident prevention measures.
WARNING: Be sure to read and understand all safety
instructions in this Operator’s Manual, including all safety
alert symbols such as “DANGER,” “WARNING,” and
“CAUTION” before using this tool. Failure to follow all
instructions listed below may result in electric shock, fire,
and/or serious personal injury.
SYMBOL MEANING
WARNING: The operation of any power
tools can result in foreign objects being thrown
into your eyes, which can result in severe
eye damage. Before beginning power tool
operation, always wear safety goggles or
safety glasses with side shields and a full face
shield when needed. We recommend a Wide
Vision Safety Mask for use over eyeglasses or
standard safety glasses with side shields.
SAFETY INSTRUCTIONS
This page depicts and describes safety symbols that may
appear on this product. Read, understand, and follow all
instructions on the machine before attempting to assem-
ble and operate it.
Safety Alert Indicates a potential personal
injury hazard.
Read
operator’s
manual
To reduce the risk of
injury, user must read and
Understand operator’s manual
before using this product.
Wear Eye
Protection
Always wear safety goggles
or safety glasses with side
shields and a full face shield
when operating this product.
CE This product is in accordance
with applicable EC directives.
WEEE
Waste electrical products
should not be disposed of
with household waste. Take
to an authorized recycler.
Do Not
Expose To
Rain
Do not use in the rain or
leave outdoors while it is
raining.
IPX5 IP Symbol Protection against ingress of
water degree 5
V Volt Voltage
mm Millimeter Length or size
cm Centimeter Length or size
kg Kilogram Weight
Direct
Current
Type or a characteristic of
current
WARNING: Read all safety warnings designated by
the symbol and all instructions.
Save all warnings and instructions for future EN
reference.
The term “power tool” in the warnings refers to your mains-
operated (corded) power tool or battery-operated (cordless)
power tool.
Original instructions

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX1000 5
EN
General Power Tool Safety Warnings –Working
area safety.
◾Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
◾Do not operate power tools in explosive
atmospheres, such as in the presence of
flammable liquids, petrol or dust. Power tools create
sparks which may ignite the dust or fumes.
◾Keep children and bystanders away while
operating a power tool. Distractions can cause you
to lose control.
General Power Tool Safety Warnings –
Electrical safety.
◾Power tool plugs must match the outlet. Never
modify the plug in anyway. Do not use any adaptor
plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk
of electric shock.
◾Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
◾Do not expose power tools to rain or wet
conditions. Water entering a power tool will increase
the risk of electric shock.
◾Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords increase
the risk of electric shock.
◾When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
◾If operating a power tool in a damp location is
unavoidable, use a Ground-fault circuit interrupter
protected supply. Use of GFCI reduces the risk of
electric shock.
General Power Tool Safety Warnings –
Personal Safety.
◾Stay alert, watch what you are doing and use
common sense when operating a power tool. Do
not use a power tool while you are tired or under
the influence of drugs, alcohol, or medication. A
moment of inattention while operating power tools may
result in serious personal injury.
◾Use personal protective equipment. Always wear
eye protection. Protective equipment such as dust
mask, non-skid safety shoes, hard hat, or hearing
protection used for appropriate conditions will reduce
personal injuries.
◾Prevent unintentional starting. Ensure the switch
is in the off-position before connecting to power
source and/or battery pack, picking up or carrying
the tool. Carrying power tools with your finger on the
switch or energizing power tools that have the switch
on invites accidents.
◾Remove any adjusting key or wrench before
turning the power tool on. A wrench or a key left
attached to a rotating part of the power tool may result
in personal injury.
◾Do not overreach. Keep proper footing and balance
at all times. This enables better control of the power
tool in unexpected situations.
◾Dress properly. Do not wear loose clothing or
jewelry. Keep your hair, clothing and gloves away
from moving parts. Loose clothes, jewelry or long hair
can be caught in moving parts.
◾If devices are provided for the connection of dust
extraction and collection facilities, ensure these
are connected and properly used. Use of dust
devices can reduce dust-related hazards.
◾Do not let familiarity gained from frequent use of
tools allow you to become complacent and ignore
tool safety principles. A careless action can cause
severe injury within a fraction of a second.
General Power Tool Safety Warnings –Power
Tool Use And Care.
◾Do not force the power tool. Use the correct power
tool for your application. The correct power tool will
do the job better and safer at the rate for which it was
designed.
◾Do not use the power tool if the switch does not
turn it on and off. Any power tool that cannot be
controlled with the switch is dangerous and must be
repaired.
◾Disconnect the plug from the power source and/
or the battery pack from the power tool before
making any adjustments, changing accessories, or
storing power tools. Such preventive safety measures
reduce the risk of starting the power tool accidentally.
◾Store idle power tools out of the reach of children
and do not allow persons unfamiliar with the
power tool or these instructions to operate the
power tool. Power tools are dangerous in the hands of
untrained users.

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX10006
EN ◾Maintain power tools. Check for misalignment or
binding of moving parts, breakage of parts and
any other condition that may affect the power
tool’s operation. If damaged, have the power tool
repaired before use. Many accidents are caused by
poorly maintained power tools.
◾Keep cutting tools sharp and clean. Properly
maintained cutting tools with sharp cutting edges are
less likely to bind and are easier to control.
◾Use the power tool, accessories and tool bits etc.
in accordance with these instructions, taking into
account the working conditions and the work to
be performed. Use of the power tool for operations
different from those intended could result in a
hazardous situation.
◾Keep handles and grasping surfaces dry, clean
and free from oil and grease. Slippery handles and
grasping surfaces do not allow for safe handling and
control of the tool in unexpected situations.
◾This 56V telescopic power pole PPX1000 may be used
with only the following EGO attachments or subsequently
introduced by EGO for use with this telescopic power pole:
ATTACHMENT TYPE MODEL NUMBER
Hedge Trimmer Attachment PTX5100
Pole Saw Attachment PSX2500
General Power Tool Safety Warnings –Battery
Tool Use And Care.
◾Recharge only with the charger specified by the
manufacturer. A charger that is suitable for one type
of battery pack may create a risk of fire when used
with another battery pack.
◾Use power tools only with specifically designated
battery packs. Use of any other battery packs may
create a risk of injury and fire.
◾When battery pack is not in use, keep it away from
other metal objects, like paper clips, coins, keys,
nails, screws or other small metal objects that can
make a connection from one terminal to another.
Shorting the battery terminals together may cause
burns or a fire.
◾Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact
accidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
◾Do not use a battery pack or tool that is damaged
or modified. Damaged or modified batteries may
exhibit unpredictable behaviour resulting in fire,
explosion or risk of injury.
◾Do not expose a battery pack or tool to fire
or excessive temperature. Exposure to fire or
temperature above 130°C may cause explosion.
◾Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specified in the instructions. Charging
improperly or at temperatures outside the specified
range may damage the battery and increase the risk
of fire.
General Power Tool Safety Warnings –Services.
◾Have your power tool serviced by a qualified repair
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.
◾Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
◾If situations occur that are not covered in this manual,
use care and good judgment. Contact the EGO Service
Center for assistance.
SAVE THESE INSTRUCTIONS
ADDITIONAL SPECIFIC SAFETY RULES CAN BE FOUND
IN THE APPLICABLE ATTACHMENT’S OPERATOR’S
MANUAL
SPECIFICATIONS
Voltage 56 V
Recommended Operating Temperature: 0°C-40°C
Recommended Storage Temperature -20°C-70°C
Weight 3.9kg
DESCRIPTION
KNOW YOUR TELESCOPIC POWER POLE (Fig. A)
1. Rear Handle
2. Locking Tongue
3. Carrying Eyelet
4. Front Handle
5. Clamping Knob
6. Shaft-release Button
7. Locking Knob
8. Coupler
9. Telescopic Tube
10. Variable Speed Trigger

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX1000 7
EN
11. Tool Support
12. Shoulder Strap
13. Ejection Mechanism
14. Latch
15. Battery Release Button
16. Wrench Holder
17. Combi Wrench
PACKING LIST (FIG. A)
ASSEMBLY
WARNING: If any parts are damaged or missing,
do not operate this product until the parts are replaced.
Use of this product with damaged or missing parts could
result in serious personal injury.
WARNING: Always remove the battery pack from
the product when you are assembling parts, making
adjustments, cleaning, or when the product is not in use.
ATTACHING AN ATTACHMENT TO THE TELESCOPIC
POWER POLE
WARNING: Read and understand entire Operator’s
Manual for each optional attachment used on this
telescopic power pole and follow all warnings and
instructions. Failure to follow all instructions could result
in electric shock, fire and/or serious personal injury.
WARNING: This 56V telescopic power pole
PPX1000 is designed to be used only with the EGO
attachment models that are specified in this Operator’s
Manual or subsequently introduced by EGO for use with
this telescopic power pole. Use of other, unauthorized
attachments could cause serious personal injuries or
property damage.
WARNING: Never install, remove, or adjust any
attachment while the telescopic power pole is running or
with the battery installed. Failure to stop the motor and
remove the battery can cause serious personal injury.
The attachment connects to the telescopic power pole by
means of a coupler device.
1. Stop the motor and remove the battery pack.
2. Loosen the locking knob.
3. Align the arrow on the attachment shaft with the
aligning indicator on the coupler and push the
attachment shaft into the coupler until you hear a
clear “click” sound, the coupler should be positioned
all the way to the reference line on the shaft that the
attachment shaft is properly mounted into place. (Fig.B).
B-1 Shaft-release Button B-4 Reference Line
B-2 Aligning Indicator B-5 Locking Knob
B-3 Arrow Mark
4. Pull the shaft of the attachment to verify that it is
securely locked into the coupler. If not, push the
attachment shaft in the coupler until it snaps into
place.
5. Tighten the locking knob securely.
WARNING: Be certain that the locking knob is
fully tightened before operating equipment; check it
periodically for tightness during use to avoid serious
personal injury.
REMOVING THE ATTACHMENT FROM THE
TELESCOPIC POWER POLE
1. Stop the motor and remove the battery pack.
2. Loosen the locking knob.
3. Press the shaft-release button, with the button
depressed, pull the attachment shift out of the
coupler.
MOUNTING THE SHOULDER STRAP (Fig. C)
Depress the strap hook to open it and attach it onto the
carrying eyelet.
EXTENDING TELESCOPIC TUBE
The tool is equipped with a telescopic tube that will
extend to 960 mm (fully extended).
The clamping knob is used to hold the telescopic tube in
position at any extended length.
1. To extend the telescopic tube, loosen the clamping
knob by following its unlock icon. The telescopic will
slide freely (Fig. D)
D-1 Clamping Knob D-2 Indication for
Maximum limit
2. Pull the telescopic tube out to desired length of
extension.
3. To locking the telescopic tube in position, tighten the
clamping knob by following its lock icon.
WARNING: In case of pinching your hand or fingers,
please cautiously watch out in every step

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX10008
EN OPERATION
WARNING:Do not allow familiarity with this product
to make you careless. Remember that a careless fraction
of a second is sufficient to inflict serious injury.
WARNING: Always wear eye protection. Failure to do
so could result in objects being thrown into your eyes and
other possible serious injuries.
WARNING: Do not use any attachments or
accessories not recommended by the manufacturer of
this product. The use of attachments or accessories not
recommended can result in serious personal injury.
INSTALLING/REMOVING THE BATTERY PACK
NOTE: Fully charge the battery pack before first use.
To Install
Align the battery ribs with the mounting slots and press
the battery pack down until you hear a “click” (Fig. E).
E-1 Mounting Slot E-2 Rib
To Remove
Depress the battery-release button and pull the battery
pack out (Fig. F).
WARNING:To avoid serious personal injury, always
remove the battery pack and keep hands clear of the locking
tongue and trigger when carrying or transporting the tool.
SHOULDER STRAP
For safe and better operation, put on the shoulder strap
across the shoulder as Fig. G to relieve the weight on the
operator’s arms. Adjust the shoulder strap in a comfort-
able operating position.
There are two ways to release the strap. Take it away
from your shoulder directly (Fig. H) or press the hook of
the strap and take it apart from the carrying eyelet fixed
on the shaft (Fig. I)
WARNING: The shoulder strap is also a quick
release mechanism in a hazardous situation. When an
emergency occurs, take it off from your shoulder immedi-
ately, no matter what way the strap is in.
HOLDING THE TELESCOPIC POWER POLE
The telescopic power pole is equipped with an advanced
dual trigger system (Fig. J). Each trigger system can
independently to switch on or off the tool. This innovated
dual-control method gives most ergonomic operation in
daily tough job. (Fig. K&L)
STARTING/STOPPING THE TELESCOPIC POWER
POLE
To start the telescopic power pole
Move the locking tongue forward and depress the variable
speed trigger to switch on the telescopic power pole. The
more pressure applied on the variable speed trigger, the
higher speed of the head attachment is
To Stop
Release the variable speed trigger and locking tongue.
MAINTENANCE
WARNING: When servicing, use only identical
replacement parts. Inspect and maintain the machine
regularly. To ensure safety and reliability, all repairs should
be performed by a qualified service technician.
WARNING: Before inspecting, cleaning or servicing
the unit, stop the motor, wait for all moving parts to stop,
and remove the battery pack. Failure to follow these
instructions can result in serious personal injury or
property damage.
NOTICE: Before each use, inspect the entire product
for damaged, missing, or loose parts such as screws,
nuts, bolts, caps, etc. Tighten securely all fasteners and
caps and do not operate this product until all missing or
damaged parts are replaced. Please contact customer
service or a qualified service technician.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use.
Use clean cloths to remove dirt, dust, oil, grease, etc.
CLEANING THE TELESCOPIC POWER POLE
1. Stop the motor and remove the battery pack.
2. Clean dirt and debris from the telescopic power pole
using a damp cloth with a mild detergent.
NOTICE: Do not use any strong detergents on the plastic
housing or the handle. They can be damaged by certain
aromatic oils such as pine and lemon.
STORING THE TELESCOPIC POWER POLE
1. Remove the battery pack from the telescopic power
pole before storing.
2. Clean all foreign material from the telescopic power
pole.
3. Store it in a place that is inaccessible to children.
4. Keep away from corrosive agents such as garden
chemicals and de-icing salts.

56 VOLT LITHIUM-ION TELESCOPIC POWER POLE — PPX1000 9
EN
Protecting the environment
Do not dispose of electrical equipment,
battery charger and batteries/
rechargeable batteries into household
waste!
TROUBLESHOOTING
See the applicable attachment’s operator’s manual.
WARRANTY
EGO WARRANTY POLICY
Please visit the website egopowerplus.com for full terms
and conditions of the EGO Warranty policy.
Table of contents
Other Ego Power+ Pole Saw manuals